OWNER’S MANUAL

LOCAL CODES

Install and use fireplace with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code ANS Z223.1
, also known as NFPA 54*.
Firebox must be electrically grounded in
accordance with the National Electrical Code,
ANS/NFPA70
 (latest edition).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY  10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA  02269

UNPACKING

1.

Use utility knife to cut carton all the
way around above the staples on the
bottom tray. Lift carton off the firebox
and discard.

2.

Remove all protective packaging from
inside firebox. Carefully lift the fire-
box off the bottom corrugated tray.

3.

Check carton contents for the
following:
• Screen assembly
• Screen support rod
• Hardware and parts bag containing

the following:
- Owner’s Operation and Installa-

tion Manual

- 2 - Black #10 x 3/8" Phillips

screws for mounting screen sup-
port rods

If any items are missing, inform dealer
where you bought firebox.

4.

Check all items for any shipping dam-
age. If damaged, promptly inform
dealer where you bought firebox.

Notice:

 The firebox identification

label (including model number,
serial number, clearances, etc.)
is located either on the left front
edge of the firebox or  behind the
left side firebrick panel. See Fig-
ure 18, page 12.

PRODUCT
FEATURES

OPERATION

This firebox is designed for use with ap-
proved ANS Z21.11.2 decorative type
unvented room heaters. (Physical size limi-
tations apply. Refer to minimum firebox
requirements supplied with log heater.) It
requires no outside venting or chimney mak-
ing installation easy and inexpensive. When
used without the blower (models FB36CB,
NLFB36C or FB42CA only), the firebox
requires no electricity making it ideal for
emergency back-up heat.

BLOWER ACCESSORY

The FB36NCA, NLFB36C, or FB42CA
fireboxes will accept the GA3700 acces-
sory. The variable blower allows you to
select the fan speed you desire. The blower
circulates heated air from the firebox into
the room. Use of blower is optional.

BRICK LINER

Your firebox may feature a concrete brick
liner. As with all concrete liners, this liner
may develop slight cracks when exposed to
heat. These cracks will not affect the perfor-
mance of the fireplace or vent-free gas logs.

LOCATING
FIREBOX

PLANNING

Plan where you will install the firebox. This
will save time and money later when you
install the firebox. Before installation, con-
sider the following:

1.

Where the firebox will be located. Al-
low for wall and ceiling clearances (see
Installation Clearances, pages 8 and 9).

2.

Everything needed to complete instal-
lation.

3.

These models CANNOT be installed in
a bedroom or bathroom.

4.

Proper air for combustion and ventila-
tion (page 5).

Summary of Contents for FB36CB

Page 1: ...adjustment alteration service or maintenance can cause injury or property dam age Refer to this manual for correct installation and opera tional procedures For assis tance or additional informa tion...

Page 2: ...laced with a hood which may be provided with a log heater 6 Do not allow fans to blow directly into the firebox Avoid any drafts that alter burner flame patterns Ceiling fans can create drafts that al...

Page 3: ...ge of the firebox or behind the left side firebrick panel See Fig ure 18 page 12 PRODUCT FEATURES OPERATION This firebox is designed for use with ap proved ANS Z21 11 2 decorative type unvented room h...

Page 4: ...g for electrical cable when hard wiring firebox for built in installations strain relief fitting included on circulating models only Gas Line Access Hole either side Electrical Access Hole for use whe...

Page 5: ...eheatlossinhomes Homeowners weather strip and caulk around windows and doorstokeepthecoldairoutandthewarmair in During heating months home owners want their homes as airtight as possible While it is g...

Page 6: ..._____________ Btu Hr Total ______________ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the...

Page 7: ...a fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors orspa...

Page 8: ...lations Wall or framing material can be placed against any exterior surface on the rear sides or top ofyourfirebox exceptwherestand offspac ersareintegrallyattached Ifstand offspac ers are attached to...

Page 9: ...gure 8a 36 41 1 4 50 29 32 72 45 TOP VIEW FOR 36 MODEL Height 37 for F 35 1 2 f 55 5 32 78 39 47 1 4 45 TOP VIEW FOR 42 MODELS Height 37 for FB4 35 1 2 for Figure 8b Figure 8c INSTALLATION Continued M...

Page 10: ...m bustible mortar or adhesives when overlapping the front fac ing with noncombustible facing material WARNING Never modify or cover the louvered slots on the front of the firebox except when using app...

Page 11: ...toff valve Check local codes for shutoff valve location requirements Figure13 InstallingGasLineandManual Shutoff Valve CAUTION Do not use exces sive force to remove the knock out Too much force may da...

Page 12: ...er see Fig ure 16 Using 2 screws provided mount blower and tighten screws securely 4 Be certain that all wire terminals are securely attached to terminals on blower motor and that the screw retain ing...

Page 13: ...lex outlet see Fig ure 22 7 Clamp electrical cable hard wiring into firebox through smallest hole using strain relief fitting provided see Fig ure 23 8 Connectelectricalcabletoduplexoutlet Match wire...

Page 14: ...actory PARTS NOT UNDER WARRANTY Contactauthorizeddealersofthisproduct If theycan tsupplyoriginalreplacementpart s call DESA International s Parts Department at 1 800 972 7879 for referral information...

Page 15: ...TER BRASS TRIM GM103U Series Unfinished Birch Veneer 36 Models Dimensions WxHxD 63 x 51 x 24 1 2 GM105U Series Unfinished Birch Veneer 42 Models Dimensions WxHxD 69 x 51 x 24 1 2 BLOWER ACCESSORY GA37...

Page 16: ...VENTED VENT FREE LOGMATE FIREBOX VANGUARD ILLUSTRATED PARTS BREAKDOWN FB36NCA NLFB36NC FB42NC 7 17 17 16 17 19 19 19 8 17 9 17 15 10 18 14 12 18 18 11 4 2 13 18 18 20 6 3 2 18 1 5 Not Included with Mo...

Page 17: ...uter Casing 1 8 103440 01 103440 01 103440 02 Outer Casing Bottom 1 9 103797 01 103797 01 103797 02 Firebox Wrapper 1 10 103297 02 103297 02 103297 02 Screen Assembly 2 11 103444 01CK 103444 01CK 1034...

Page 18: ...NTED VENT FREE LOGMATE FIREBOX VANGUARD ILLUSTRATED PARTS BREAKDOWN FB36CB NLFB36C FB42CA 7 17 17 16 17 19 22 22 22 8 17 9 17 15 21 20 10 18 14 12 18 18 11 4 2 3 2 18 13 18 18 6 1 5 Not Included with...

Page 19: ...Bottom 1 9 103797 01 103797 01 103797 02 Firebox Wrapper 1 10 103297 02 103297 02 103297 02 Screen Assembly 2 11 103444 01CK 103444 01CK 103444 02CK Hood 1 12 103442 01CK 103442 01CK 103442 03CK Front...

Page 20: ...rtation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE...

Reviews: