Vanguard FB36CA Owner'S Operation And Installation Manual Download Page 3

3

103451

OWNER’S MANUAL

PRODUCT
SPECIFICATIONS

Figure 1 -  Firebox Front View

Figure 2 -  Firebox Side View

41 11/16" (36" models) • 47 11/16" (42" models)

36" (36" models) • 42" (42" models)

15 7/8"

35"

2 5/8"

2 5/8"

6 5/8"

19 3/8"

Built-in Nailing
Flanges

Standoffs (Models FB36NCA
and FB42NC only)

Louvers
(Models FB36CA
and FB42C only)

6 7/8"

1 1/2"

Diameter Holes

9 5/8"

8 7/16"

2 3/4"

1 1/2"

10 3/4"

13 9/16"

3 1/2"

Standoffs (Models FB36NCA and FB42NC only)

Electrical Access Hole
Strain relief fitting for electrical cable when hard
wiring firebox for built-in installations (strain relief
fitting included on circulating models only)

Gas Line Access
Hole (either side)

Electrical Access
Hole
(for use when
using blower
power cord with
external electrical
outlet. See
Blower Kit
Instructions)

Figure 3 -  Firebox Top View

30 3/8" (36" Models) • 36 7/8" (42" Models)  

42 3/8" (36" Models) • 48 3/8" (42" Models)  

36" (36" Models) • 42" (42" Models)

41" (36" Models) • 47" (42" Models)

29 1/8" (36" Models) • 35 1/8" (42" Models)

19 1/2"

22 1/4"

5/8"

Summary of Contents for FB36CA

Page 1: ...lla tion adjustment alteration service or maintenance can cause injury or property dam age Refer to this manual for correctinstallationandopera tional procedures For assis tance or additional informa...

Page 2: ...Do not run firebox where flammable liquids or vapors are used or stored under dusty conditions 10 Do not use this firebox to cook food or burn paper or other objects 11 Never place any objects in the...

Page 3: ...1 2 Standoffs Models FB36NCA and FB42NC only Electrical Access Hole Strain relief fitting for electrical cable when hard wiring firebox for built in installations strain relief fitting included on ci...

Page 4: ...x This will save time and money later when you install the firebox Before installation con sider the following 1 Where the firebox will be located Al low for wall and ceiling clearances see Installati...

Page 5: ...ustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used ______________ Btu Hr maximum the space can support ____...

Page 6: ...ovide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outd...

Page 7: ...will not work properly Note YourVanguardfireboxisdesignedto be used in zero clearance installations Wall or framing material can be placed against any exterior surface on the rear sides or top ofyour...

Page 8: ...20 FB42NC 47 1 4 37 20 FB42C 47 1 4 35 1 2 20 ROUGH OPENING DIMENSIONS FOR BUILT IN INSTALLATION Depth Minimum Width Inside to Inside Height TABLE 1 Figure 8a 36 41 1 4 50 29 32 72 45 TOP VIEW FOR 36...

Page 9: ...WARNING Useonlynon com bustible mortar or adhesives when overlapping the front fac ing with non combustible facing material WARNING Never modify or cover the louvered slots on the front of the firebox...

Page 10: ...stallingshutoff valve Check local codes for shutoff valve location requirements Figure13 InstallingGasLineandManual Shutoff Valve CAUTION Do not use exces sive force to remove the knock out Too much f...

Page 11: ...ht hand side of firebox Remove screw holding duplex outlet to support bracket in bottom of firebox Remove duplex outlet see Fig ure 19 7 Clamp electrical cable hard wiring into firebox through smalles...

Page 12: ...art to the factory Parts Not Under Warranty Contact authorized dealers of this product If they can t supply original replacement part s call DESA International s Parts Department at 1 800 972 7879 for...

Page 13: ...dress listed on the back page of this manual CABINET MANTEL ACCESSORY WITH FIREBOX PERIMETER BRASS TRIM GM103U Series Unfinished 36 Models Dimensions WxHxD 63 x 51 x 24 1 2 GM105U Series Unfinished 42...

Page 14: ...14 103451 UNVENTED VENT FREE LOGMATE FIREBOX VANGUARD ILLUSTRATED PARTS BREAKDOWN FB36NCA AND FB42NC 7 17 17 16 17 19 19 19 8 17 9 17 15 10 18 14 12 18 18 11 4 2 13 18 18 20 6 3 2 18 1 5...

Page 15: ...6 103720 01 103720 02 Bottom Firebrick 1 7 103796 01 103796 02 Outer Casing 1 8 103440 01 103440 02 Outer Casing Bottom 1 9 103797 01 103797 02 Firebox Wrapper 1 10 103297 02 103297 02 Screen Assembl...

Page 16: ...16 103451 UNVENTED VENT FREE LOGMATE FIREBOX VANGUARD ILLUSTRATED PARTS BREAKDOWN FB36CA AND FB42C 7 17 17 16 17 19 8 17 9 17 15 21 20 10 18 14 12 18 18 11 4 2 3 2 18 13 18 18 6 1 5...

Page 17: ...om Firebrick 1 7 103796 01 103796 02 Outer Casing 1 8 103440 01 103440 02 Outer Casing Bottom 1 9 103797 01 103797 02 Firebox Wrapper 1 10 103297 02 103297 02 Screen Assembly 2 11 103444 01CJ 103444 0...

Page 18: ..._________________________________ _______________________________________________________________________________________________ ______________________________________________________________________...

Page 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 20: ...cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTH...

Reviews: