Vanguard EBDV34N Owner'S Operation And Installation Manual Download Page 30

30

106417

DIRECT-VENT FIREPLACE

®

For more information, visit www.desatech.com

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• fireplace will not produce specified heat

When Gas Quality Is Bad

• pilot will not stay lit

• burners will produce flames and soot

• fireplace will backfire when lit

If you feel your gas pressure is too low or gas
quality is bad, contact your local natural gas
supplier.

TECHNICAL
SERVICE

You may have further questions about in-
stallation, operation, or troubleshooting. If
so, contact DESA International’s Technical
Service Department at 1-800-DESA LOG
(1-800-337-2564).

You can also visit DESA International’s
technical service web site at

www.desatech.com

.

REPLACEMENT
PARTS

Figure 57 - Wiring Diagram for Fireplace

WIRING DIAGRAMS

 CAUTION: Label all wires prior to disconnection when servicing

controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.

Note: 

Use only original replacement parts.

This will protect your warranty coverage for
parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If
they can not supply original replacement
part(s), call DESA International’s Technical
Service Department at 1-800-DESA LOG
(1-800-337-2564).

When calling DESA International, have ready

• your name

• your address

• model and serial numbers of your fireplace

• how fireplace was malfunctioning

• type of gas used (propane/LP or natural

gas)

• purchase date

Usually, we will ask you to return the defec-
tive part to the factory.

PARTS NOT UNDER
WARRANTY

Contact authorized dealers of this product.
If they can not supply original replacement
part(s), call DESA International’s Parts De-
partment at 1-800-972-7879 for referral in-
formation.

When calling DESA International, have ready

• model number of your fireplace

• the replacement part number

Control
Valve

Pilot

Robertshaw

MODEL SP745 IGNITION CONTROL

STEP DOWN

TRANSFORMER

PV

GND

PV/MV

TR

MV

TH

IGN

EV2

SUPPLY

INCOMING
MAIN GAS

EV1

TO 

GAS LINE

 BURNER

24V AC

120V AC

120V AC

INCOMING

OR BREAKER)

(FUSE BOX

OFF

ON

(SUPPLIED)

WALL SWITCH

GREEN

BLACK

WHITE

120v, 60Hz, 0.7A

ELECTRICAL RATING:

BLACK

WHITE

GREEN

OPTIONAL
REMOTE

CONTROL

Ignitor

Hearth Pan

Connectors
(Not Supplied)

Field Wire

Blue

Variable

Fan Switch

Fan Switch

(N.O.)

Green

White

On

110/115 

V.A.C.

Blower

Motor

Black 

Off

1

2

Black

Figure 56 - Blower Wiring Diagram for Thermostat-Controlled Models

Summary of Contents for EBDV34N

Page 1: ...anceoradditionalinformation consult a qualified installer ser vice agency or the gas supplier This appliance may be installed in an aftermarket manufactured mobile home where not prohibited by local c...

Page 2: ...indicated on fire place nameplate 14 This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electri cal Code ANS...

Page 3: ...c igni tion models require household electricity to operate Figure 1 Vanguard Direct Vent Fireplace EBDV Series Glass Door Assembly Blower Adjustment Optional Installation Valve Burner Pilot Assembly...

Page 4: ...um 1 clearance to combustibles 34 3 4 37 1 2 41 1 2 34 1 4 34 3 4 36 3 4 20 Vertical Termination 19 Horizontal Termination Note Where three numbers are given the top number is exclusive to the 34 Fire...

Page 5: ...Vent GS venting components or kits spe cifically approved for this fireplace Important Do not mix Vanguard and Simpson Dura Vent venting Minimum clearance between vent pipes and combustible materials...

Page 6: ...above paved side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minim...

Page 7: ...ermination Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Terminati...

Page 8: ...combination of pipe and el bows to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have four locking lugs inden...

Page 9: ...fire hazard 4 Apply a bead of non hardening mastic around the outside edge of the vent cap Position the vent cap in the center of the 7 1 2 or 10 hole on the exterior wall with the arrow on the vent c...

Page 10: ...h corner installation UP Flexible Vent Pipe Horizontal Venting See information in Figure 18 for Vertical V and Horizontal H maximums and minimums The same amounts apply for flexible venting Note Figur...

Page 11: ...8 min 20 max 20 max 8 max 20 max Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 19 Horizontal Termination Con...

Page 12: ...g members Note Pay spe cial attention to these installation in structions for required clearances air space to combustibles when passing through ceilings walls roofs enclo sures attic rafters etc Do n...

Page 13: ...ically and horizontally using a level Temporarily tack the support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corners down to t...

Page 14: ...VENTING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Figure 27 Vertical Rigid Vent...

Page 15: ...al vanized Pipe 7 12 Firestop Support Roof Flashing RTV Silicone Vertical Termination and 26 screws D1000 7 x 12 Galvanized Coaxial Pipe 6 pcs D1010 7 x 24 Galvanized Coaxial Pipe 6 pcs D1020 7 x 48 G...

Page 16: ...tem you may run system scirculatingblowerwhile using heater This will help circu late the heat throughout the house In the event of a power outage you can use this heater as your primary heat source W...

Page 17: ...f exiting through the right side see Figure 33 Route power cord through both plastic bushing s and plug the power cord into a properly grounded 3 prong wall receptacle near the firebox b If your firep...

Page 18: ...ac ceptable alternative to test gauge connec tion Purchase the CSA design certified equipment shutoff valve from your dealer WARNING A qualified ser vice person must connect fire place to gas supply...

Page 19: ...of fireplace 3 Attach a 45 flare union gas connector to flexible gas line from gas supply see Figure 36 Connect flare union to flex ible gas line attached to gas regulator of fireplace see Figure 36...

Page 20: ...hutoff valve see Figure 37 2 Open propane LP supply tank valve for propane LPfireplace or main gas valve located on or near gas meter for natu ral gas fireplace 3 Make sure control knob of fireplace i...

Page 21: ...s to be connected to the incoming 120 volt regular household wiring that supplies electricity to the fireplace Refer to wiring diagram on page 30 NOTICE The GWMS2 includes 25 of wire for installation...

Page 22: ...d the side of the firebox see Figure 44 4 Slide the left retainer bracket against the left side brick panel Loosely se cure the bracket screw This secures the left side brick panel 5 Install the right...

Page 23: ...t modify logs Only use logs supplied with fireplace Removeglassdoor SeeRemoving Replacing GlassDoor page21 Installlogsaccordingto instructions for fireplace model numbers 1 Place log 1 back log on top...

Page 24: ...five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety in formation in column one If you don t smell gas go to the next step 7 Tu...

Page 25: ...ill shut off after the firebox temperature decreases The blower helps distribute heated air fromthefireplace Periodicallycheckthe louvers of the firebox and remove any dust dirt or other obstructions...

Page 26: ...corrosion of caps pipes and fittings and can be caused by having excessive lateral runs too many elbows or exterior portions of the system be ing exposed to cold weather 4 Inspect joints to verify tha...

Page 27: ...me may be too low causing safety pilot to drop out 2 Vent may be blocked or restricted REMEDY 1 Check to see if you have gas supply and that the equipment shutoff valve is opened 2 Repeat lighting pro...

Page 28: ...burner until air is removed from line Have gas line checked by local natural gas company 2 Clean burner see Cleaning and Maintenance page 26 or replace burner orifice 1 Adjust the log set so that the...

Page 29: ...ove 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control k...

Page 30: ...authorized dealers of this product If they can not supply original replacement part s call DESA International s Technical Service Department at 1 800 DESA LOG 1 800 337 2564 WhencallingDESAInternatio...

Page 31: ...c Minimum Inlet Supply Pressure 4 5 w c 4 5 w c 4 5 w c Dimension Inches mm HxWxD Fireplace 32 3 16 x 34 3 8 x 18 1 2 33 x 37 x 18 1 2 35 x 41 x 18 1 2 817 x 873 x 470 mm 838 x 940 x 470 mm 838 x 1041...

Page 32: ...ech com 34 3 1 2 3 23 21 20 22 4 6 19 7 7 8 9 10 11 Included in Hardware Pack 12 13 14 15 16 17 18 25 26 27 28 28 29 31 33 35 36 35 35 37 38 5 5 5 24 48 49 39 44 45 35 46 47 30 43 6 41 40 42 6 32 34 2...

Page 33: ...7222 01 Transformer 24 VAC 1 21 23416 Mounting Board Electronic 1 22 107221 01 Ignition Module 1 23 14104 Plug 2 Prong 1 24 104514 01 Wall Switch 1 25 104504 01 Burner 1 26 104506 01 Orifice 34 37 1 1...

Page 34: ...go at the top and bottom of the glass door Note Remove the plasticfilmcoveringonstripsbeforeinstall ing on fireplace BRICK LINER D8037A 34 37 D8041 41 Not Shown This brick liner adds a touch of style...

Page 35: ...G3003B Series Black Onyx Marble Laminate SLIM HEARTH BASE Not Shown G3005J Series Jade Marble Laminate G3005S Series Sandstone Marble Laminate G3005B Series Black Onyx Marble Laminate The slim hearth...

Page 36: ...e the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES A...