![Vanguard BHDV37N Owner'S Operation And Installation Manual Download Page 34](http://html1.mh-extra.com/html/vanguard/bhdv37n/bhdv37n_owners-operation-and-installation-manual_853295034.webp)
34
104558
DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)
®
(B)HDV37N/P AND (B)HDV41N/P
SPECIFICATIONS
BHDV/HDV37N
BHDV/HDV37P
BHDV/HDV41N
BHDV/HDV41P
17,000/24,000 Btu/h
17,000/22,000 Btu/h
18,000/26,000 Btu/h
19,000/24,000 Btu/h
Gas Type
Natural
Propane/LP
Natural
Propane/LP
Ignition
Piezo
Piezo
Piezo
Piezo
Manifold Pressure
3.5" w.c.
10.0" w.c.
3.5" w.c.
10.0" w.c.
Minimum Inlet Supply Pressure
4.5" w.c.
11.0" w.c.
4.5" w.c.
11.0" w.c.
Thermal Efficiency
70%
70%
70%
70%
Dimension, Inches/mm (HxWxD)
Fireplace
33" x 37" x 18
1
/
2
"
33" x 37" x 18
1
/
2
"
33" x 41" x 18
1
/
2
"
33" x 41" x 18
1
/
2
"
838 x 940 x 470mm
838 x 940 x 470mm
838 x 1041 x 470mm
838 x 1041 x 470mm
Carton
37" x 43" x 21"
37" x 43" x 21"
37" x 47" x 21"
37" x 47" x 21"
940 x 1092 x 533mm
940 x 1092 x 533mm
940 x 1194 x 533mm
940 x 1194 x 533mm
Weight, lbs/kg
Fireplace
132 lbs/60 kg
132 lbs/60 kg
142 lbs/64 kg
142 lbs/64 kg
Shipping
135 lbs/61 kg
135 lbs/61 kg
145 lbs/66 kg
145 lbs/66 kg