Vanguard BDV34NA Owner'S Operation And Installation Manual Download Page 28

28

105980

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

®

BDV34NA AND BDV34PA

OBSERVED PROBLEM

Burner does not light after pilot is lit

Delayed ignition burner

Burner backfiring during combustion

Slight smoke or odor during initial operation

Heater produces a whistling noise when
burner is lit

Glass soots

Fireplace produces a clicking/ticking noise
just after burners are lit or shut off

Remote does not function

REMEDY

1. Clean burner (see Cleaning and

Maintenance, page 26) or replace burner
orifice

2. Contact local propane/LP or natural gas

company

3. Reconnect leads (see Wiring Diagram,

page 30)

4. Replace thermopile

1. Contact local propane/LP or natural gas

company

2. Clean burner (see Cleaning and Main-

tenance, page 26) or replace burner orifice

1. Clean burner (see Cleaning and

Maintenance, page 26) or replace burner
orifice

2. Replace damaged burner
3. Replace gas control

1. Problem will stop after a few hours of

operation

1. Turn gas control knob to LO position and

let warm up for a minute

2. Operate burner until air is removed from

line. Have gas line checked by local pro-
pane/LP or natural gas company

3. Clean burner (see Cleaning and

Maintenance, page 26) or replace burner
orifice

1. Adjust the log set so that the flame does

not excessively impinge on it

2. Inspect the opening at the base of the

burner to see that it is NOT packed with
any type of material

1. This is common. If noise is excessive,

contact qualified service person

1. Replace 9-volt batteries in receiver and

remote control

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Burner orifice clogged

2. Inlet gas pressure is too low

3. Thermopile leads disconnected or im-

properly connected

4. Thermopile is defective

1. Manifold pressure is too low

2. Burner porting or orifice clogged

1. Burner orifice is clogged or damaged

2. Damaged burner
3. Gas regulator defective

1. Residues from manufacturing processes

and logs curing

1. Turning gas control knob to HI position

when burner is cold

2. Air in gas line

3. Dirty or partially clogged burner orifice

1. Flame impingement on logs

2. Debris around burner air mixer

1. Metal expanding while heating or con-

tracting while cooling

1. Battery is not installed or battery power

is low

www.desatech.com

Summary of Contents for BDV34NA

Page 1: ...assis tanceoradditionalinformationcon sult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket manufactured mobile home where not prohibited by s...

Page 2: ...properly seated and sealed If this unit is not properly installed by a qualified service person with glass door properly seated and sealed gas leakage can occur Carbon Monoxide Poisoning Early signs...

Page 3: ...PIEZO IGNITOR This fireplace has a piezo ignitor This sys tem requires no matches batteries or other sources to light fireplace Figure 1 Vanguard Direct Vent Fireplace BDV Series Glass Door Assembly...

Page 4: ...LEARANCES Minimum clearances to combustibles for the fireplace are as follows Back and sides 0 mm Perpendicular walls 6 152mm Floor 0 mm Ceiling to louver opening 42 1067mm Front 36 914mm Top of Stand...

Page 5: ...and combustible materials is 1 25 mm except where stated otherwise Combustible material may be flush with the top front of fireplace with a maxi mum thickness of 3 4 Do not recess venting terminals in...

Page 6: ...ove paved side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minimum...

Page 7: ...proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Termination Select the amount of vertical rise desired The horizon tal...

Page 8: ...ows to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have four locking lugs indentations These lugs will slide...

Page 9: ...al Boltthe ventcaptothestandoff Applynon hard ening mastic around outside edge of the standoff instead of the vent cap assem bly Use wood screws provided to attach the standoff See Figure 14 5 Slide t...

Page 10: ...ith corner installation UP Horizontal Venting See information in Figure 17 for Vertical V and Horizontal H maxi mums and mini mums The same amounts apply for flexible venting Note Figure 16 applies to...

Page 11: ...max 8 min 8 min 20 max 20 max 8 max 20 max Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 19 Horizontal Termi...

Page 12: ...as specified in the second warning state ment on page 7 Be sure all pipe and elbow connections are fully twist locked see Figure 11 page 9 3 Cut a hole in the roof using the locating hole as a center...

Page 13: ...page 12 Continued Figure 23 Cathedral Ceiling Support Box Installation Non hardening Mastic under all edges of support box before nailing Figure 24 Installed Cathedral Ceiling Support Box Vertical Ter...

Page 14: ...ration With No Horizontal Run VENTING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max...

Page 15: ...oaxial Pipe 6 pcs D1010 7 x 24 Galvanized Coaxial Pipe 6 pcs D1020 7 x 48 Galvanized Coaxial Pipe 6 pcs D1030 7 Adjustable 7 12 Galvanized Coaxial Pipe 6 pcs D1050 7 x 6 Galvanized Coaxial Pipe 6 pcs...

Page 16: ...ex screws into all three pieces and tighten 3 Insert the top screw through the ther mal switch bracket and into the blower assembly Tighten screw 4 Connect the blue wire on the blower assembly to the...

Page 17: ...see Figure 33 Route power cord through both plastic bushing s and plug the power cord into a properly grounded 3 prong wall receptacle near the firebox b If your fireplace system installation is rece...

Page 18: ...son must connect fire place to gas supply Follow all local codes CAUTION For propane LP units never connect heater di rectly to the propane LP supply This heater requires an external regulator notsupp...

Page 19: ...provided by installer from manual shutoff valve to fireplace Route flexible gas supply line through one of the access holes on side of fireplace 3 Attach flexible gas line from gas sup ply to control...

Page 20: ...for propane LP or Figure 39 for natural Apply commercial leak test so lution to all gas joints Bubbles forming show a leak Correct all leaks at once 5 Light fireplace see Operating Fire place pages 2...

Page 21: ...ormation see Replacement Parts page 30 1 Remove the upper louver panel by lift ing upward and out see Figure 44 2 Remove the screws from the three tabs at the top of the glass door while hold ing door...

Page 22: ...de of the firebox see Figure 46 4 Slide the left retainer bracket against the left side brick panel Loosely se cure the bracket screw This secures the left side brick panel 5 Install the right brick p...

Page 23: ...tion thepartsinaccordancewiththese diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury 1 Place log 1 back log on top of grate...

Page 24: ...ssing for lighting 8 Turn gas control knob counterclock wise to PILOT 9 Push in control knob all the way and hold Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a f...

Page 25: ...F position the blower will not operate Note for CDA3610T Only If you are using CDA3610T blower your fireplace and blower will not turn on and off at the same time The fireplace may run for several min...

Page 26: ...ace and let cool before cleaning CAUTION Youmustkeepcon trol areas burners and circulat ing air passageways of fireplace clean Inspect these areas of fire place before each use Have fire place inspect...

Page 27: ...loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut hold...

Page 28: ...rner until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 26 or replace burner orifice 1 Adjust the log set...

Page 29: ...er log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OF...

Page 30: ...disconnection when servicing controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Note Use only original replacement parts Thiswillprotectyourwarra...

Page 31: ...upply Pressure 4 5 w c 11 0 w c Dimension Inches mm HxWxD Fireplace Actual size of firebox Measurements do not 32 3 16 x 34 3 8 x 18 1 2 32 3 16 x 34 3 8 x 18 1 2 include nailing flanges or 817 x 873...

Page 32: ...Series Black Onyx Marble Laminate SLIM HEARTH BASE Not Shown G3005J Series Jade Marble Laminate G3005S Series Sandstone Marble Laminate G3005B Series Black Onyx Marble Laminate The slim hearth base al...

Page 33: ...uvers will give your fireplace an elegant look and allows you to customize your fireplace They easily replace the stan dard black louvers by screwing into place DECORATIVE 2 PIECE BRASS ACCENT TRIM D5...

Page 34: ...34NA AND BDV34PA ILLUSTRATED PARTS BREAKDOWN BDV34NA BDV34PA 47 1 2 3 4 6 7 7 8 9 10 11 Included in Hardware Pack 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 29 30 31 3 31 2 31 4 31 1 32 33...

Page 35: ...02 SIT Pilot Propane LP 1 19 104498 01 Thermocouple 1 20 104499 01 Thermopile 1 21 104500 01 Ignitor 1 22 104501 01 Ignitor Bracket 1 23 104502 01 Ignitor Screw 1 24 104503 01 Ignitor Wire 1 25 10450...

Page 36: ...ing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED...

Reviews: