Vanguard Aristocrat V42E Installation Instructions Manual Download Page 9

9

55510

Figure 23

A

B

CEILING
SUPPORT
PIPE
V12S-8DM

2"
MINIMUM

ANGLE
FIRESTOP

DETAIL B

SEE

DETAIL B

INSTALL SUPPORT 12S-8DM

DETAIL A

SEE

DETAIL A

RETURN

ELBOW

Figure 24

OFFSET
ELBOW

OFFSET
ELBOW

OFFSET
ELBOW

OFFSET
ELBOW

OFFSET
ELBOW

RETURN
ELBOW

RETURN
ELBOW

RETURN
ELBOW

RETURN
ELBOW

CEILING
SUPPORT
PIPE
V12S-8DM

RETURN
ELBOW

6' MAX

6' MAX

6' MAX

6' MAX

6' MAX

6' MAX

A

B

C

RISE AND OFFSETS

A

B

48 36 18 12

A

B

48

36 18 12 12S

4

3

/

8

16

3

/

8

41

1

/

4

80

1

/

4

1

1

1

1

9

3

/

4

25

1

/

2

1

45

86

3

/

4

2

1

12

3

/

4

30

3

/

4

1

46

3

/

4

89

1

/

2

1

1

1

1

15

34

3

/

4

2

51

97

1

1

1

18

40

1

1 53

1

/

4

101

2

1

1

21

1

/

4

46

1

/

4

1

56

1

/

4

106

1

/

4

2

1

23

3

/

4

49

1

/

4

1

2 59

1

/

4

111

1

/

2

1

1

1

1

27

3

/

4

56

3

/

4

1

61

3

/

4

115

1

/

2

2

1

1

30

60

3

/

4

1

1

64

3

/

4

120

3

/

4

2

1

1

33

66

1

1 68

1

/

4

127

1

2

1

36

71

1

1

70

130

2

1

1

1

38

1

/

4

75

2

74

1

/

4

137

1

/

2

1

2

1

1

76

3

/

4

141

1

/

2

1

2

1

1

79

3

/

4

146

3

/

4

4

1

Figure 25  

                                                              TYPICAL OFFSET INSTALLATION

INSTRUCTIONS WHEN OFFSET OF CHIMNEY IS
NEEDED

TO INSTALL ELBOWS

1.  To achieve desired offset, you may install combinations of 12",

18", 36", and 48"  lengths of double wall pipe (see Rise and
Offsets
 chart and Figures 23 and 25).

2.  Chimney weight above offset rests on return elbow.  Straps must be

securely nailed to rafters or joists (see Figure 24 details A and B).

3.  Maximum length of pipe supports (return elbow or V12S-8DM)

is 6' of angled run.  Maximum of two (2) 6' angled run sections
per chimney system (see Figure 25).

NOTE: ANY OFFSET GREATER THAN 6 FEET MUST USE A
V12S-8DM. ALSO FOR STRAIGHT RUN OVER 30 FT. LEVEL.

All joints between offset shall be secured with two screws,
only on the outer pipe, and shall not penetrate the inner
stainless. See illustration above.

f i r e - p a r t s . c o m

Summary of Contents for Aristocrat V42E

Page 1: ...ed 17 1 2 22 41 13 16 37 3 8 HEARTH EXTENSION 66 X 20 STORM COLLAR 42 38 7 16 22 1 16 43 1 4 8 1 2 12 3 4 22 12 1 4 GAS LINE CONDUIT SLEEVE BOTH SIDES 3 4 AIR SPACE BACK AND SIDES OUTSIDE AIR LEFT SID...

Page 2: ...e materials and the chimney must be abso lutely maintained A 16 1 2 inch inside chase dimension is recom mended as a minimum size A 3 4 inch air space required around back and sides of fireplace Keep...

Page 3: ...OF THE FIREPLACE MUST NOT BE OB STRUCTED NEVER USE BLOWN INSULATION TO FILL THE CHIMNEY ENCLOSURE SEE FIGURE 4 Figure 3 8 IN STAINLESS INNER PIPE HEMMED END 12 3 8 GALVANIZED OUTER PIPE LINEAL GAIN TH...

Page 4: ...E FACTORY COVER PLATE WITH STRAIN RELIEF TO WALL SWITCH EXISTING J BOX IN FIREPLACE WIRE NUT TYP 30 FT 30 FT RETURN ELBOW V12S 8DM SUPPORT V12S 8DM SUPPORT Figure 5 Figure 6 Figure 7 FIRESTOP SPACERS...

Page 5: ...2 Determine the pitch of the roof Pitch is the distance the roof dropsoveragivenspan usually12inches A6 12pitchmeansthatthe roof drops 6 inches for each 12 inches measured horizontally STEP 3 From the...

Page 6: ...E Agaslinemaybeinstalledforthepurposeofinstallingagasappliance available through your local distributor Use only 1 2 black iron pipe and appropriate fittings When installing a gas line a shut off valv...

Page 7: ...Figure 16 STANDARD HEARTH SEAL GAP SEAL GAP DO NOT BLOCK INTAKE GRILL EMBER PROTECTOR EMBER PROTECTOR ELEVATED FIREPLACE RAISED HEARTH HEARTH EXTENSIONS MODEL V42EC HEARTH EXTENSIONS MODEL V42E DAMPE...

Page 8: ...ials may overlap the front face provided they do not obstruct essential openings like louveredslotsoranyotheropenings Whenoverlappingwithnoncom bustiblefacingmaterial useonlynoncombustiblemortaroradhe...

Page 9: ...81 4 127 1 2 1 36 71 1 1 70 130 2 1 1 1 381 4 75 2 741 4 1371 2 1 2 1 1 763 4 1411 2 1 2 1 1 793 4 1463 4 4 1 Figure 25 TYPICAL OFFSET INSTALLATION INSTRUCTIONS WHEN OFFSET OF CHIMNEY IS NEEDED TO INS...

Page 10: ...to 6 12 EMBER PROTECTOR EP 36 ROUND TOP TERMINATION VRTL 8DM VRTTL 8DM VADS 8DM ECONO TOP TERMINATION VETO 8DM VETLO 8DM GLASS DOOR KIT VDG42E AIR KIT VAK4E ADJUSTABLE HOOD BLACK GA6050 POLISHED BRAS...

Reviews: