TENT PITCHING INSTRUCTIONS 

 SOLARIS (UK) 

Flysheet First Pitching: 

 

Open out flysheet and position in required direction 

 

Peg out the four main corners of the tent using the pegs supplied 

 

Locate inflation points on each beam 

 

Remove the valve cap (figure 1) 

 

Insert the correct pump adaptor, which will lock onto the valve (figure 2 & 3) 

 

There is no need to turn the white valve button as the adaptor will move this to the correct position 

 

Inflate all tubes to 7psi. The tubes MUST be guided into an arch as they are inflated. 

 

Final tube pressure MUST NOT exceed 8psi 

 

DO NOT OVER-INFLATE THE BEAMS 

 

Start with the centre tube and guide the beam into an upright position while it is inflating 

 

Inflate the other beams. 

 

A small amount of air may leak from the valve when it is being inflated but this is normal 

 

Remove the pump adaptor as soon as the beam is at the correct psi 

 

Replace the valve cap to create an air tight seal (figure 5 & 6) 

 

Ensure the tent is in a straight line 

 

The groundsheet should be flat and wrinkle free 

 

Peg out the remaining poles and pegging points using pin pegs at the base of poles 

 

Peg out ALL guy lines using pin-pegs ensuring that guy line fabric attachment points are evenly tensioned.  

 

Reposition and adjust tensioning where necessary 

CORRECT PUMP SET-UP: 

 

Pump Body > Pressure Valve > Pressure Gauge > Hose 

 

(Ensure the valve/gauge/hose are connected to the inflation port of the pump) 

Pre-Attached sun canopy: 

 

Insert the pole through the front pole sleeve, then tension the material using the front guy lines. Peg out the base of the sun canopy. 

 

Vango awnings are designed for use in lowland, sheltered campsites. Do not pitch in high winds or exposed campsites 

 

To stow, unpeg guy lines, remove pole and roll back canopy toward tent. Secure with loops until required. 

Inner Attachment: 

 

Open out inner tent inside flysheet and position doorways to correspond with the living area 

 

Starting from the rear corners of the tent, attach the elasticated hooks on the groundsheet to corresponding rings on the flysheet 

 

Suspend the inner by attaching toggles of inner tent through rings on inside of flysheet 

 

Do the rear first and work forward 

Tension Band System: 

 

Remove Tension Band System from pockets and attach into the corresponding clips at the apex of the pole 

 

Adjust the straps until they are taut 

 

DO NOT OVERTENSION. Excess tension will alter the shape of the tent 

TO DEFLATE  AIRBEAM/ AIRAWAY/ AIRAWNING:  

 

To deflate the AirBeam (remove the cap (figure 7)) press & turn (figure 8) the button from CLOSED to OPEN 

In the unlikely event of a puncture: 

 

Deflate the air beam. Unzip the internal flysheet sleeve which contains the affected beam. 

 

Remove the tube and its protective outer. 

 

The zips for the protective outer are cable tied together to prevent accidental access. Cut the cable tie and open the zip.  

 

DO NOT open these zips when the tube inflated. 

 

Remove the clear rubberised tube from the protective sleeve taking care when removing the valve from the sleeve. 

 

Partially inflate the tube and pass through a bucket or basin of water, looking for air bubbles. This will indicate location of puncture 

 

Use the repair patch provided and cover hole, using instructions on patch. Re-insert tube into protective outer, closing zip from both ends, so that zip pullers are in the flysheet sleeve 
(this might be easier with the tube partially inflated) 

 
 

AIRBEAM INFLATION:

 

     

 

 

 

 

 

 

 

AIRBEAM DEFLATION: 

 

 

 
 

 

Aufbauanleitung - Solaris  (DE) 
Mit Außenzeltaufbau zuerst  

 

Außenzelt auslegen und korrekt ausrichten. 

 

Befestigen Sie die 4 Hauptecken des Zelts mit Hilfe der mitgelieferten Heringe 

 

Lokalisieren Inflation Punkte auf jeder Strahl 

 

Entfernen Sie die Ventilkappe 

 

Legen Sie die richtige Pumpenadapter , die auf das Ventil sperren wird 

 

Es besteht keine Notwendigkeit , um die weiße Ventilknopf drehen, da der Adapter wird diese in die richtige Position bewegen 

 

Pumpen Sie alle Schläuche auf 3psi auf. Die Schläuche MÜSSEN beim Aufpumpen in einen Bogen geformt werden. 

Figure 1 

Remove 
locking cap 

Figure 3 

Lock locking pump 
connector 

Figure 4 

Inflate with 
AirBeam pump 

Figure 5 

Insert locking 
cap 

Figure 6 

Lock locking cap 

Figure 8 

Push button to deflate & 
twist to open position 

Figure 7 

Unlock 
locking cap 

Figure 2 

Insert locking pump 
connector 

Reviews: