background image

VG-SBW330CMY  330W  CMY  LED  Moving  Head  Spot  Light  User  Manual                        VG-SBW330CMY  330W  CMY  LED  Moving  Head  Spot  Light  User  Manual   

⚫ Multi-goboes                  ⚫ Color strobe   
⚫ Electronic Dimming 0-100%      ⚫ DMX-512 protocol   
⚫ Master/Slave synchronization    ⚫ LCD operation menu with function buttons                                 
⚫ Daisy Chain Units Together in DMX Mode 

 

 SAFETY INFORMATION                                                                           

Important 

Every person involved with the installation, operation and maintenance of this device has to 

be  qualified  and  follow  the  instructions  of  this  manual.  Manufacturer  will  not  with 

responsibility for those operations which are not according to this Instruction.   

Verify that the voltage matches the rated voltage. 

When the voltage is 110V , Do not connect more than 10 lightings in total to AC mains 

power in one interconnected daisy chain   

When the voltage is 220V , Do not connect more than 20 lightings in total to AC mains 

power in one interconnected daisy chain   

Before  using  the  fixture,  check  that  all  power  distribution  equipment  and  cables  are  in 

perfect condition and rated for the current requirements of all connected devices. 

Always ground (earth) the fixture electrically. 

Avoiding hit the Light when you are move or install the light. 

The minimum distance between light

←→

output and the illuminated surface must be more 

than 0.5 meters. Keep all combustible materials (for example fabric, wood, paper) at least 

0.2 meters away from the fixture. 

Do not expose the fixture to rain or moisture. 

Avoid looking directly into the light source (especially those who suffer from epileptic fits) 

Maximum ambient temperature (Ta) is 40°C. Do not operate fixture at temperatures higher 

than this.   

The Maximum surface temperature is 50°C 

When suspending the fixture above ground level, verify that the structure can hold at least 

10 times the weight of all installed devices. 

Verify that all external covers and rigging hardware are securely fastened and use an 

approved means of secondary attachment such as a safety cable.   

To determine the power requirements for a particular fixture, see the label affixed 

to the back plate of the fixture or refer to the fixtures specifications chart. A fixture listed 

current rating is its average current draw under normal conditions. All fixtures must be 

directly powered off a switched circuit and cannot be run off a rheostat(variable resistor) or 

dimmer circuit, even if the rheostat or dimmer source voltage matches the fixtures 

requirement. Check the fixture or device carefully to make sure that if a voltage selection 

switch exists that it sets to the correct line voltage you will use. 

 

Warning! 

Verify that the voltage select switch on your unit matches the line voltage 

applied. Damage to your fixture may result if the line voltage applied does not match the 

voltage indicated on the voltage selector switch. All fixtures must be connected to circuits 

with a suitable Earth ground. 

 

 OPERATION INSTRUCTIONS     

                                                                                                   

 

The moving head is an LED wash light for onsite decoration purpose. 

 

Don‟t turn on the fixture if it‟s been through severe temperature difference like after 

transportation because it might damage the light due to the environment changes. So 

make sure to operate the fixture until it is in normal temperature. 

 

This light should be keep away from strong shaking during any transportation or 

movement. 

 

Don‟t pull up the light by only the head, or it might cause damages to the mechanical 

parts. 

 

Don‟t expose the fixture in overheat, moisture or environment with too much dust 

when installing it. And don‟t lay any power cables on the floor. Or it might cause 

02 

03 

Summary of Contents for VG-SBW330CMY

Page 1: ...User Manual VG SBW330CMY 330W CMY LED Moving Head Spot Light User Manual 330W CMY LED Moving Head Spot Light VG SBW330CMY CE RoHS User Manual Please read this user manual before using this product Ke...

Page 2: ...mperature strength of engineering ABS with nice outlook The fixture is designed manufactured strictly following CE standards complying with international standard DMX512 protocol It s available indepe...

Page 3: ...spending the fixture above ground level verify that the structure can hold at least 10 times the weight of all installed devices Verify that all external covers and rigging hardware are securely faste...

Page 4: ...ATION Electrical Power supply electronic auto ranging Input voltage range supply 90 250V 50 60Hz Fuse 5 A 220V Power consumption 450W 230V Optic Light source LED Apportronics 1piece 330W White LED LED...

Page 5: ...ght When installing the device make sure there is no highly inflammable material decoration articles etc in a distance of min 1 0 m CAUTION Use an appropriate clamp to ring the fixture on the truss Fo...

Page 6: ...each individual fixtures traits with a standard DMX 512 controller DMX Mode Operating through a DMX controller give the user the freedom to create their own programs tailored to their own individual n...

Page 7: ...100degree CH7 252 255 239 251 226 238 213 225 208 212 108 207 104 107 004 103 000 003 Strobe Shutter Open Random Strobe Fast Random Strobe Medium Random Strobe Slow Open Pulse Slow Fast Open Strobe Sl...

Page 8: ...n CW Fast Slow Gobo7 Shake Slow Fast Gobo6 Shake Slow Fast Gobo5 Shake Slow Fast Gobo4 Shake Slow Fast Gobo3 Shake Slow Fast Gobo2 Shake Slow Fast Gobo1 Shake Slow Fast Gobo7 Gobo6 Gobo5 Gobo4 Gobo3 0...

Page 9: ...Random Strobe Fast 226 238 Random Strobe Medium 213 225 Random Strobe Slow 208 212 Open 108 207 Pulse Slow Fast 104 107 Open 004 103 Strobe Slow Fast 000 003 Close CH6 000 255 Cyan 0 100degree CH7 00...

Page 10: ...Open CH14 Gobo Rotation 193 255 Gobo Rotation CCW Slow Fast 191 192 Stop 128 190 Gobo Rotation CW Fast Slow 000 127 Gobo Position CH15 Iris 192 255 Iris Pulse Closing Slow Fast 128 191 Iris Pulse Ope...

Page 11: ...mpletely before plugging the unit back in Cleaning frequency depends on the environment in which the fixture operates i e smoke fog residue dust dew Unit not respond to DMX 1 Check that the DMX cables...

Reviews: