background image

12

3. CONTROLS (

CONT

D

)

 3.2 

E

LECTRICAL

 C

ONNECTION

 

TO

 O

PTIONAL

 W

ALL

 C

ONTROLS

3.2.1 E

LECTRICAL

 C

ONNECTION

 

TO

 A

LTITUDE

 

OR

 P

LATINUM

 M

AIN

 W

ALL

 C

ONTROL

3.2.2 E

LECTRICAL

 C

ONNECTION

 

TO

 D

ECO

-T

OUCH

 

M

AIN

 W

ALL

 C

ONTROL

3.2.3 E

LECTRICAL

  C

ONNECTION

 

TO

  L

ITE

-T

OUCH

 

C

ONSTRUCTO

 

OR

  B

RONZE

OR

  S

IMPLE

-T

OUCH

 

C

ONSTRUCTO

 

OR

 B

RONZE

 M

AIN

 W

ALL

 C

ONTROLS

3.2.4 E

LECTRICAL

 C

ONNECTION

 

TO

 C

ONSTRUCTO

 

OR

 B

RONZE

 M

AIN

 W

ALL

 C

ONTROL

NO  C   NC   I   OC OL   Y   R    G   B

VE0181

SMART

SET

MODE
PREF

NO  C   NC   I   OC OL   Y   R    G   B

VE0250

NO  C   NC   I   OC OL   Y   R    G   B

OC 

MAIN WALL CONTROLS

LITE-TOUCH CONSTRUCTO,

LITE-TOUCH BRONZE,

SIMPLE-TOUCH CONSTRUCTO

and SIMPLE-TOUCH BRONZE

REAR VIEW

G  B 

VE0113A

NO  C   NC   I   OC OL   Y   R    G   B

VE0187

For more convenience, this unit can also be controlled using an optional main wall control. 
NOTES: 1.  The integrated control must be turned OFF to use an optional main control.
 

2.  If an optional auxiliary control is used, if activated, this auxiliary control will override the optional main control operation.

CAUTION

Never install more than one main wall control per unit. Make sure that the wires do not short-circuit between 
themselves or by touching any other components on the wall control. Avoid poor wiring connections. To reduce 
electrical interference (noise) potential, do not run wall control wiring next to control contactors or near light dimming 
circuits, electrical motors, dwelling/building power or lighting wiring, or power distribution panel.

Use the terminal connector included in the installation kit to perform the electrical 
connection for main and optional wall controls. Check if all wires are correctly inserted 
in their corresponding holes in the terminal block. (A wire is correctly inserted when its 
orange receptacle is lower than another one without wire. On illustration at right, wire 

A

 is correctly inserted, but not wire 

B

.)

Splice back the end of the cable to access the 4 wires. Strip the end of each wire. 
Connect each wire to its corresponding terminal: YELLOW wire to “Y’’, RED wire to “R’’, 
GREEN wire to “G’’ and BLACK wire to “B’’. Check if all wires are correctly inserted in 
their corresponding holes in the terminal block.
Connect the auxiliary control cable, if installed (not shown). 

VE0272

A

B

   WARNING

Always disconnect the unit before making any connections. Failure in disconnecting power could result in electric 
shock or damage of the wall control or electronic module inside the unit.

!

Summary of Contents for Venmar AVS 41656

Page 1: ...ERGY STAR requirements only when used in Canada 21784 rev 01 INSTALLATION GUIDE FOR VENMAR AVS UNITS CONSTRUCTO 1 2 ERV AND V NEE 60H ERV Model no 41556 ERV with top ports Model no 41554 ERV with side...

Page 2: ...sion cord 7 Do not install in a cooking area or connect directly to any appliances 8 Do not use to exhaust hazardous or explosive materials and vapors 9 When performing installation servicing or clean...

Page 3: ...NSTALLING 2 EXTERIOR HOODS 10 2 9 INSTALLING THE TANDEM TRANSITION KIT 10 3 CONTROLS 11 13 3 1 INTEGRATED CONTROL 11 3 2 ELECTRICAL CONNECTION TO OPTIONAL WALL CONTROLS 12 13 3 2 1 ELECTRICAL CONNECTI...

Page 4: ...in the lowest liveable level Homes with more than one level require at least one exhaust register at the highest level See figure at right 1 2 CENTRAL DRAW POINT CONNECTION TO A FORCED AIR SYSTEM Stal...

Page 5: ...H0102 2 INSTALLATION 2 1 INSPECT THE CONTENTS OF THE BOX Inspect the exterior of the unit for shipping damage Ensure that there is no damage to the door door latches power cord etc Remove and discard...

Page 6: ...rew them from the unit Install the latches on their new locations VD0176 Latches on sides of the unit Latches in front of the unit VB0094 VO0089 VO0090 2 4 HOW TO HANG THE UNIT Hang the unit with the...

Page 7: ...a register must be floor installed direct the airflow up the wall 2 6 2 CENTRAL DRAW POINT SYSTEM AS ILLUSTRATED IN SECTION 1 2 Stale air exhaust ductwork Same as for Fully Ducted System described on...

Page 8: ...tions to the furnace air handler NOTE For Method 1 it is not essential to synchronize the furnace blower operation with the unit operation but we recommend it WARNING When performing duct connections...

Page 9: ...of the double collar then pull down the vapor barrier shaded part in illustrations below over the insulation and over the outer ring of double collar Apply duct tape to the joint making an airtight se...

Page 10: ...e grill Any exhaust from a combustion source Garbage bin and any other source of contamination VD0028 EXHAUST HOOD INTAKE HOOD TAPE AND DUCT TIE 18 457 MM 6 1 8 M 18 457 MM 18 457 MM 6 1 8 M 6 152 MM...

Page 11: ...control If a problem occurs during the unit operation its integrated control LED 2 will blink The color of the blinking light depends on the type of error detected Refer to Section 8 TROUBLESHOOTING o...

Page 12: ...between themselves or by touching any other components on the wall control Avoid poor wiring connections To reduce electrical interference noise potential do not run wall control wiring next to contro...

Page 13: ...Amber light LOW speed Green ligh HIGH speed Blinking light See User Manual Sans lumi re Arr t ou contr l par contr le mural Lumi re ambre Basse vitesse Lumi re verte Haute vitesse Clignotant Voir guid...

Page 14: ...2 9 5 V class 2 120 V neutral J9 1 J9 2 J9 3 J4 2 J9 4 Exhaust fan motor capacitor Supply fan motor capacitor J8 1 J8 2 J8 4 J8 5 K4 J12 2 J12 1 A1 Damper motor J3 2 J3 1 J2 2 J2 1 F1 J12 5 J12 4 J12...

Page 15: ...running in defrost while balancing By waiting 10 minutes after plugging the unit in you are assured that the unit is not in a defrost cycle 2 Place the magnehelic gauge on a level surface and adjust i...

Page 16: ...ommends to contact a certified service depot for all replacement parts and repairs NO DESCRIPTION PART NO 41554 ERV SIDE PORTS 41556 ERV TOP PORTS 41654 ERV SIDE PORTS 41656 ERV TOP PORTS 1 OVAL PORT...

Page 17: ...l is set The shortest delay is obtained when the wall control is set on MIN or MAX in VENT Mode Ensure the RED wire is not damaged and properly connected 3 Altitude Platinum or Deco Touch wall control...

Page 18: ...rk but exhaust motor works The supply motor may be defective The supply motor capacitor or the PCB may be defective Plug supply motor to J5 connector and exhaust motor to J4 connector If the integrate...

Reviews: