Output Type
Description
Confirmed
holdup
Activates in the following scenarios for PD6662 compliance:
l
two hold-up zone activations more than two minutes apart
l
a hold-up zone and a panic zone activation more than two minutes apart
l
if a hold-up zone and a tamper zone or a panic zone and a tamper zone activation occurs within
the two minute period
Full Engineer
Activates if an engineer is on site and the system is in full engineer mode.
* This output type can only indicate system wide events (no area specific events).
1
A WPA is compatible with SiWay RF Kit (SPCW110, 111, 112, 114 ) only.
See also
Configuring system latch and auto set outputs
16.13 Communication
1. Scroll to COMMUNICATION and press SELECT.
2. Scroll to the desired programming option.
16.13.1 Serial Ports
The serial ports allow older style PCs to be connected to the system or other peripheral equipment like
printers.
1. Scroll to SERIAL PORTS.
2. Press SELECT.
3. Scroll to the serial port to be programmed.
4. Select the desired programming option shown in the table below.
TYPE
Determines if type is TERMINAL (system information) or PRINTER (SPC event
log).
BAUD
RATE
Determines the speed of the communication between the panel and the
peripheral equipment. Note that the baud rate must be set the same as both items
of equipment.
DATA
BITS
Determines the length of data packet to be transferred between the panel and the
peripheral equipment. Note that the data bits must be set the same for both items
of equipment.
STOP
BITS
Determines the number of stop bits at the end of the data packet. Note that the
stop bits must be set the same for both items of equipment.
PARITY
Determines the parity (odd/even) of the data packet. Note that the parity must be
set the same for both items of equipment.
FLOW
CONTROL
Determines if the data is under hardware (RTS, CTS) or software control (None).
Note that the flow control must be set the same for both items of equipment.
5. Press BACK to exit.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the keypad
© Vanderbilt 2018
157
A6V10276959-d
11.2018