17.10.1.3 Configuring system latch and auto set outputs
1. Under
Policy
, click the
Edit
button for the
Output Configuration
option in
System Options
.
The following page is displayed:
2. Select the condition under which the latch output is activated:
Entry Time
Output turns on at the end of Exit time and off at the beginning of Entry
time.
Fire Exit
Output turns on if any fire exit zones are active.
Unset
Output turns on if any user unsets system momentary
Alarm Reset
Output turns on if an alarm is reset momentary.
Resetting
Alarm
Output turns on during a setting procedure if glass break/smoke open and
not in alarm.
Engineer Exit
Output turns on when an engineer exits from Engineer mode momentary.
Keypad Valid
PIN
Output turns on when valid user PIN entered on keypad and fire zone is
active
3. Select the behavior of the output.
On
Output will remain on if auto set is active.
Keypad
Output will follow keypad operation.
Progressive
Output will give progressive warning of auto set.
Pulse Time
Select the duration that the auto set output will remain active when pulsed.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the browser
© Vanderbilt 2018
236
A6V10276959-d
11.2018