Installation Instructions
08.02.2016
5.5
Connection assignment
There are four different connection types for the remote testing system as follows:
Connection type A
Field wiring (X2 terminal
block)
Ribbon cable connections (X1 terminal
block)
Connection assignment between
intruder alarm system and GMTA7-
S.
10
SPARE
9
SPARE
8
SPARE
7
TAMPER B
6
TAMPER A
5
SPARE
4
SPARE
3
DAY NIGHT IN
2
+ 12V IN
1
0V IN
Connection type B
Field wiring (X2 terminal
block)
Ribbon cable connections (X1 terminal
block)
Connection assignment between
GM775 seismic detector and
GMYA7-A.
10
KSM_TEST OUT
Connect terminal 4 of a GM775 seismic de-
tector to one of the two
KSM_TEST OUT
terminals in the indicator module (multiple
use, maximum 4 conductors per terminal).
Connect the
EL Alarm(12)
alarm outputs
of the individual seismic detectors to
KSM_0 IN
…
KSM_7 IN
.
9
KSM_TEST OUT
8
KSM_7 IN
7
KSM_6 IN
6
KSM_5 IN
5
KSM_4 IN
4
KSM_3 IN
3
KSM_2 IN
2
KSM_1 IN
1
KSM_0 IN