Setting the OSD screen
© Vanderbilt 2016
26
Trigger
"Setup" menu – "Trigger" option
Trigger Enable
Enables/disables the trigger function
Trigger Input
Selects the input source for the trigger
Buzzer
Not available
Trigger Time
Selects the time period (3 – 100 s) during which the monitor displays the
trigger input image.
Trigger Option
Selects the type of physical trigger input
N/C (Normally Closed): The trigger function is activated when the trigger
cable is opened.
N/O (Normally Open) and Low: The trigger function is activated when
the trigger cable is closed.
High: The trigger function is activated when the trigger signal is DC 2 - 5
[V].
Low: The trigger function is activated when the trigger signal is DC 0 -
0.6 [V].
Display Type
Selects the mode in which the monitor displays the trigger input.
PIP&FULL: Displays the trigger input in the PiP mode of the current
video input source.
Note: The main video source must support the trigger input source as a
PiP option.
FULL: Switches the display to show the trigger input in full screen mode.
Auto Switching
Auto Switching
Activates the Auto Switching feature
Input Enable
Selects the input sources to include in the Auto Switching cycle
Time
Selects the time period (3 – 100 s) during which the monitor displays
each selected input source