© 2017 Vanderbilt
4 / 4
021_AGB800-AM_I-200259_EN
PROTECTING SEVERAL WINDOWS BY ONE DETEC-
TOR
Detector can protect several windows in one room if the win-
dows are within the coverage area. Make independent DRC
test for each window to be protected. Follow the procedure
above for each window. The detector shall be set to the lowest
Zone number that is the longest range from the detector.
TIMEOUT
Both the AGB800-AM detector and ADT700 tester are
equipped with a timeout feature. The AGB800-AM will stop the
DRC mode and the ADT700 will switch off power if no activity
has happened within 3
–4 minutes.
D/N CONTROL (Day/Night)
The D/N makes it possible to remote control the alarm indica-
tions of the detectors and remote reset during DAY->NIGHT
transition. The D/N increases the security of the detector, as it
enables the alarm indications to be concealed in NIGHT mode
without any influence on the relay function.
SELF-TEST
Detector is continuously checking all vital parts responsible for
proper detection of glass break signal using internal self-test
procedure.
ANTI-MASKING
Test of antimasking system:
1. Put the power on. Seal microphone completely with elastic
material like chewing gum or isolation tape.
2. INTRUSION and FAULT relays will open after max. of 180
s signaling masking of microphone.
3. Remove sealing material from microphone. Relays will
close in less than minute.
Issued by Vanderbilt
Clonshaugh Business and Technology Park
Clonshaugh, Dublin 17
D17 KV84, Ireland
www.vanderbiltindustries.com
Doc ID: I-200259 Edition Date: 01.05.2017
UNDERSTANDING THE LED WHEN THE DETEC-
TOR IS IN OPERATION
LED
Detector status
Flashes 1
–3 times
when powered ON
Indication of range setting after power-on
Off
Normal state, no alarms
Permanently on
Intrusion detected
– if detector in Latch
mode
Permanently on
with 1 blink per 3s
Masking detected
Permanently on
with 2 blinks per 3s
Low supply voltage or self-test failure
Short blink
Antimasking warning
– foreign object in
close proximity of microphone
UNDERSTANDING THE LED WHEN TESTING THE
DETECTOR WITH ADT700 TESTER
LED
Detector status
Flickers
In test mode
Flickers and blinks
In calibration mode
Flashes 1.5s
Confirms received signal
Blinks slowly 1 time each
2.5s after calibration
Set range setting to Zone 1 (4
–9m)
Blinks slowly 2 times each
2.5s after calibration
Set range setting to Zone 2 (2
–4m)
Blinks slowly 3 times each
2.5s after calibration
Set range setting to Zone 3 (1
–2m)
TROUBLESHOOTING
Detector does not respond
Check the supply voltage and polarity
LED permanently on
Switch off the detector for a short period
Check if LED is in latching mode (DIP1=ON)
LED permanently on with 1 dip per 3 s
Check if microphone not masked with foreign material
LED permanently on with 2 dips per 3 s
Check supply voltage
– should be higher than 7 V
No alarm
Check the INTRUSION and FAULT relay wiring
Check the alarm loop wiring
TECHNICAL DATA
Type (thickness) of protected glass
float (4mm), laminated P2, P4 (4mm + 4mm)
Size of protected glass
min 40 × 40 cm
Max range
9m radius/165°
Range setting
Zone 1 = 4
–9m
Zone 2 = 2
–4m
Zone 3 = 1
–2m
Supply voltage
7
–30V DC
Max. voltage ripple
2 Vpp at 12V, 4 Vpp at 24V
Voltage monitoring
Fault signaled at < 7V
Current consumption quiescent state
12mA @ 12V, 7mA @ 24V
D/N signal levels
DAY = D/N open or < 2.5V, NIGHT = D/N > 2.5V
INTRUSION output, FAULT output
relay
INTRUSION and FAULT relay contact rating
50mA, 50V
DC/peak AC, Rs ≤ 30Ω
TAMPER contact rating
50mA/50V DC/peak AC
Intrusion/fault indication
LED
Environmental class
EN50130-5:2011, VdS 2110 Class I
Operating temp. range
-25°C to +40°C
Operating humidity range
max. 93% RH
Housing material
plastic ABS, white
Dimensions [WxHxD]
68 x 109 x 40 mm
Security grade
EN 50131-2-7-1:2012/A1:2013, Grade 3, VdS class B
Approvals
ORDERING INFORMATION
Type
Art No.
Description
Weight
AGB800-AM
V54535-Z129-A100
Acoustic glass break detector G3
0.126Kg
Accessory
ADT700
N54535-Z100-A100
Acoustic glass break tester
0.743Kg