background image

www.vanco1.com

800.626.6445

27

LIABILITY STATEMENT 

Every effort has been made to ensure that this product is free of defects. The manufacturer 

of this product cannot be held liable for the use of this hardware or any direct or indirect 

consequential damages arising from its use. It is the responsibility of the user and 

installer of the hardware to check that it is suitable for their requirements and that it is 

installed correctly. All rights are reserved. No parts of this manual may be reproduced 

or transmitted by any form or means electronic or mechanical, including photocopying, 

recording or by any information storage or retrieval system without the written consent of 

the publisher.  

Manufacturer reserves the right to revise any of its hardware and software following its 

policy to modify and/or improve its products where necessary or desirable. This statement 

does not affect the legal rights of the user in any way. 

Summary of Contents for Evolution EVMX4044

Page 1: ...Vanco Part Number EVMX4044 Quick Install HDMI 4x4 Matrix Selector Switch over Single Cat5e Cat6 Cable www vanco1 com 800 626 6445 HDMI 4x4 MATRIX SELECTOR SWITCH over Cat5e Cat6 Cable...

Page 2: ...ularly at the plugs 9 Use unit only with accessories specified by the manufacturer 10 Refer all servicing to qualified personnel CAUTION HDMI is a very complex technology requiring continuous authenti...

Page 3: ...ick Install HDMI 4x4 Matrix over Single Cat5e Cat6 Cable Part EVMX4044 Allows up to 4 HDMI sources to be distributed simultaneously to up to 4 displays Transmission Range Extends 1080p resolution up t...

Page 4: ...232 connector DE 9 9 pin D sub female 3 5mm connector Matrix Unit Earphone jack for IR blaster All IR Out IR control on all source devices IR1 IR4 IR control on individual source device Earphone jack...

Page 5: ...el 8 Output Port 1 4 RJ 45 outputs for each output channel 9 INPUT 1 4 HDMI inputs 10 IR Receiver 1 4 Infrared 3 5mm socket for plugging in the extension cable of IR receiver 11 System IR Receiver Ext...

Page 6: ...displays are capable to play the HDMI signals normally RECEIVERS 1 5V DC Connect to 5V DC power supply 2 HDMI OUT Connect to a HDMI display with a HDMI male male cable 3 EQ ROTARY DIAL If you see flic...

Page 7: ...ch EDID Settings There are nine embedded default EDID settings as shown below OPERATION CONTROL FRONT PANEL 1 INPUT OUTPUT MAPPING Use the LEFT or RIGHT push button to select the output desired to swi...

Page 8: ...cle button shown below to select Input 2 to Output 3 2 Function Key Button Function OFF Standby mode ON Power on the matrix switcher STATUS Preset output status SAVE Save current mapping mode PRESET P...

Page 9: ...800 626 6445 9...

Page 10: ...tware control through RS 232 OPERATION CONTROL SOFTWARE CONTROL THROUGH RS 232 AND LAN PORT 1 I O Routing Button 2 Rename I O Button 3 EDID Button 4 Network Button 5 F W Update Default Reset Button 6...

Page 11: ...Mapping I O Select the input Click Send to change the I O setting Save Mapping Select Mapping 1 8 Click Save button to save current mapping Preset Mapping Select Mapping 1 8 Click Recall button to re...

Page 12: ...www vanco1 com 12 2 Rename I O Button Rename I O Rename output name Rename input name Rename Mapping Rename Mapping name...

Page 13: ...lect output Select Input Click Send button to learn display EDID Load EDID File to Input Select Input Click Load button to select the EDID file View EDID Select Input or HDMI output Click View button...

Page 14: ...www vanco1 com 14 4 NETWORK Save Setting Save the IP address which is manually entered Read Setting Read the IP address from the device The default IP address is 192 168 1 111...

Page 15: ...STEM BUTTON Firmware Update 1 Version To get the F W version information 2 Factory Reset 3 Help To view the steps of the firmware update 4 Firmware Update Main Board 5 Firmware Update Web IC 6 Firmwar...

Page 16: ...nco1 com 16 6 COM PORT SELECTION Click button to select COM Port 7 CONNECTION STATUS Connected Status Connecting Status Disconnected Status 8 CONNECT DISCONNECT Click this button to change connection...

Page 17: ...to Ethernet function If Ethernet is connected the button will emit to show that ethernet is connected 9 RS 232 10 ETHERNET Click button to switch to RS 232 function If RS 232 is connected the button...

Page 18: ...Password matrix 1 I O Routing Button 2 Setting Button 3 EDID Button 1 Refresh Mapping 2 I O a Select the input 3 Save Mapping a Select Mapping 1 8 b Click Save button to save current mapping 4 Recall...

Page 19: ...the password has to be 6 characters a Key in old password b Key in new password c Key in new password again 3 EDID 1 Learn EDID from Default a Select Default EDID 1 8 Default EDID b Select Input c Cl...

Page 20: ...www vanco1 com 20 CONNECTION DIAGRAM...

Page 21: ...front of the IR receiver eye Double sided adhesive tape provided 5 Plug in IR receivers to the port of the display receiver baluns IR RX the receivers are labeled IR RX use provided double sided adhe...

Page 22: ...atrix unit EVMX4044 place blaster in front of the IR eye of the corresponding source IR RECEIVER EV IRRX Plug IR Receiver into IR RX port of matrix unit EVMX4044 place receiver at or near correspondin...

Page 23: ...lacement of IR Blaster and Receiver may result in the failure of the unit Please check carefully before plugging in the IR accessories into the respective IR sockets 3 If your HDMI display has multipl...

Page 24: ...the hot plug concept With all of the HDMI cables disconnected turn on the source and plug in the HDMI cable into it s output then power up the Vanco unit and plug the HDMI cable into it s input final...

Page 25: ...risk of damage to the unit Follow all instructions and warnings marked on this unit Do not attempt to service this unit yourself except where explained in this manual Provide proper ventilation and a...

Page 26: ...est to Vanco A surge protector power conditioner unit or an uninterruptible power supply must be installed in the electrical circuit to protect against power surges If repairs are needed during the wa...

Page 27: ...table for their requirements and that it is installed correctly All rights are reserved No parts of this manual may be reproduced or transmitted by any form or means electronic or mechanical including...

Page 28: ...Vanco International 506 Kingsland Drive Batavia Illinois 60510 call 800 626 6445 fax 630 879 9189 visit www vanco1 com...

Reviews: