VANAIR.COM • 800-526-881            START•ALL

®

 HYDRAULIC SERIES TROUBLESHOOTING GUIDE 

FIXING REVERSE POLARITY GENERATORS 

(ONLY USED IF REVERSE POLARITY IS SUSPECTED)

If your unit is continually blowing the 30 amp fuse in the voltage control line, you could have reversed/negative polarity 

generator. To fix this, you must have either a 12 volt jump pack or a 12 volt battery with jumper cables. Do the procedure on 

the far left generator and then repeat the same step on the one right next to it. 

THE 12  VOLT JUMP PACK OR 12 VOLT 

BATTERY HAS TO BE IN GOOD WORKING CONDITION.

WHEN USING A 12 VOLT BATTERY 

(WILL ALSO REQUIRE A SET OF JUMPER CABLES)

1. Hook the jumper cables up to the battery with the black clamp on the negative post and the red clamp on the positive

post. 

 

DO NOT LET THE OTHER ENDS TOUCH, OR THERE WILL BE SEVERE SPARKING THAT COULD CAUSE

DAMAGE.

2. With the other end of the cables, take the negative black clamp and put it on a good ground on the unit.
3. Scratch the positive red clamp across the field post of the generator, which is the smaller of the two posts on top of the

generator. It is normal to see sparks while doing this. Do not attach the positive cable clamp; you must scratch it across

the field post.

4. Once you have done this a few times, you will have reversed the polarity back to positive in all of the generators, as long

as the wires have been hooked back up correctly.

FIG. 8

JUMPER TO FRAME 

GROUND OR A 

KNOWN GROUND

FRAME GROUND

JUMPER TO FIELD POST

FIG. 9

SWITCH

TROUBLESHOOTING FOR START

ALL

®

 UNIT

WHEN USING A 12 VOLT JUMP PACK

1. Put the negative clamp to a good ground on the unit.
2. Turn the jump pack on while holding onto the positive cable. Scratch it across the field post on the generator, which is

the smaller of the two posts on top of the generator. 

It is normal to see sparks while doing this.

  

Do not attach the positive

cable clamp to the field post as this may cause damage to the generator. You must scratch it across the field post.

3. Once you have done this a few times, you will have reversed the polarity back to positive in all of the generators, as long

as all the wires have been hooked back up correctly.

FIG. 5

FIG. 6

FIG. 7

ARMATURE POST

FIELD 

POST

SMALL SOLENOID TERMINAL 

CONTAINING THE BROWN WIRE

SWITCH SIDE 

CONNECTOR TO 

FIELD POST

Start•All

®

 610 pictured

Summary of Contents for Goodall START-ALL Hydraulic Series

Page 1: ...START ALL HydraulicSeriesTroubleshootingGuide Start All Hydraulic Series Troubleshooting Guide Rev 11122019...

Page 2: ...TIONS INSTRUCTIONS 3 4 GENERAL INSPECTION 5 GENERATOR TEST 5 TESTING THE SOLENOIDS 6 TESTING THE VOLTAGE CONTROL 6 FIXING REVERSE POLARITY GENERATORS 7 12 24 VOLT RED LABEL VOLTAGE CONTROL TEST 8 RED...

Page 3: ...rdous situation which if not avoided could result in death or serious injury to the operator or bystanders WARNING Indicates a potentially hazardous situation which if not avoided may result in modera...

Page 4: ...NEVER BOOST A FROZEN BATTERY rupture or explosion could occur causing serious personal injury Vehicle owner s manual may indicate further precautions which also should be followed when attempting to b...

Page 5: ...eated If no solder ring is found each generator needs to be tested When testing the 79 406 79 510 isolated ground generator the ground stud on the bottom of the generator must be grounded by running a...

Page 6: ...F YOUR UNIT HAS THE TWO WIRE 70 600 K VOLTAGE CONTROL YOU WILL NEED TO CALL VANAIR MFG AT 844 526 8817 FOR AN UPGRADE KIT 1 Confirm the fuse on the orange wire is not open If open replace with a 30 am...

Page 7: ...f the two posts on top of the generator It is normal to see sparks while doing this Do not attach the positive cable clamp you must scratch it across the field post 4 Once you have done this a few tim...

Page 8: ...ssembly CHECK THE ON POSITION FOR 24V SIDE 1 Move the switch to the 24V side 2 Measure for continuity between the purple and black wires coming from the switch 3 Is there continuity between the purple...

Page 9: ...9 VANAIR COM 800 526 881 START ALL HYDRAULIC SERIES TROUBLESHOOTING GUIDE MAINTENANCE LOG...

Page 10: ...hnical support it is important to provide the serial number of the Start All unit The serial number will be a white tag with black type located on the front panel on the Start All FOR TECHNICAL SERVIC...

Reviews: