5.2 ENGINE START-UP AND
SHUTDOWN PROCEDURE
Consult
Figure 5-1: Instrument Panel Functions
for
operating procedures detailed in this section.
5.2.1 ENGINE START-UP
Consult
Figure 5-2
, and the following steps:
1. Check to make sure all switches [
A
] (for
Welder and Generator) are in the
OFF
position prior to starting.
2. Turn the engine control switch from the
OFF
to the
ON
position [
B
]; wait 3-5 seconds for
the fuel pump to prime the system.
3. Continue turning control switch to the
START
position [
C
] until the engine starts (when the
switch is let go, it will revert back to
ON
position).
4. Let engine run at idle for a 3-5 minutes to
allow for warm up sequence. Engine may
run at full speed until pressure builds up in
the tank.
Operating the Generator
5.5
page 49
Operating the Air Compressor
5.6
page 49
Operating the Battery/Boost Charger
5.7
page 51
Connection - Disconnection Sequence
and Operation
5.7.1
page 51
Extreme Condition Operation
5.8
page 52
Cold Weather Operation
5.8.1
page 53
Engine Operation
5.8.1.1
page 53
High Temperature Operation
5.8.2
page 53
High Altitude Operation
5.8.3
page 53
System Operation Group
Manual
Section
Location
Engine Start-up and Shutdown Procedure
5.2
page 43
Engine Start-up
5.2.1
page 43
Engine Shutdown
5.2.2
page 44
System Operation Group
Manual
Section
Location
NOTE
Air compressor will start automatically
with machine start-up.
NOTE
Regarding the compressor: once the
machine has built up full pressure, it will
immediately idle down.
NOTE
Engine fault light will be on with the key
switch turned to the ON position before
starting the engine.