background image

4'1:D1ntroduction 

Thank you  for purchasing  this VanGuard  microscope.  With the user  in  mind,  VanGuard  microscopes  are built 

from modern designs and should provide a lifetime of reliable performance. Before using this microscope it must 

be properly setup, which requires some familiarity with the microscope. For this reason we recommend you read 

this entire manual carefully before setting up and using the instrument. 

14001Ni Series Inverted Microscopes 

Vanguard 1400INi Series inverted microscopes 

are suited for observation of blologlcal cultures 

or  specimens within well plates,  petri dishes, 

slides and vials. 
Viewing  Head. 

Rotatable  trinocular  (Seidentopf) 

head  is  inclined  at  30

°

.  All  models  feature 

interpupillary and dioptric adjustment. The trinocular 

head features a sliding main prism (80/20 spin) to 

provide full-time imaging when the vertical tube is 

in use (80% of the image to the vertical tube and 

20% to the eyetubes). 

Eyepieces. 

1 OX  uttra-widefield  (DIN)  with a field 

diameter of 22mm. 

Nosepiece. 

Quintuple, ball-bearing nosepiece with 

high-grade lubricant and posnive stops. 

Objectives. 

Plan  achromatic,  infinity  corrected 

objectives  come  standard  on  both  models. 

Objectives are made  to DIN standards and are 

optically coated. 

Stage. 

The fixed stage measures 160 x 250mm and 

300 x  250mm  with  stage  extensions/mechanical 

stage  attached.  Mechanical  stage  accepts  96 

well  microplate  and  included  stage  inserts: 

Terasaki/65mm petri dish,  1 x  3" slide/54mm petri 

dish,  35mm petri dish. Motion of mechanical stage 

is controlled by a right-hand,  low-posttion coaxial 

control and is driven by a rack and pinion system. 

Focusing  movement.  Coaxial,  ultra-low posttion 

coarse  and  fine  focus  controls  feature  a  40mm 

focusing range and are graduated to 2 microns per 

division. Fitted with a tension adjustment. 

Condenser. 

Brightfield models come with a  0.30 

N.A. condenser. Phase contrast models come with 

a  0.30 N.A.  condenser with phase annulus slider 

for  1 0X/20X, and 40X; also has a open setting for 

brightfield work. All condensers are factory centered 

and aligned for ease of setup and include an iris 

diaphragm, and a slide-in fitter holder. 

Illumination. 

30W variable  quartz  halogen  light 

source.  Comes  with  blue,  green  (model  1493INi 

only), and dispersion filters.  1 A,  250V fuses. 

Body. 

Cast-metal,  ergonomic  body  with  stain­

resistant enamel finish. 

[ Table of Contents 

Introduction ........................................................................ 

Parts 

Accessories 

lnduded Parts ........................................................................  3 

OptionalAccessories .............................................................  4 

Microscope Diagrams ......................................................... � 

Setup 

Assembly........................................................................  7-12 

Using Your 1400INi Microscope 

Power SwitchNariable Lighting Control .................................  12 
lnterpupillary and Diopter Adjustment... ................................... 9 

Focusing and Mechanical Stage Mechanisms ........................  13 
Using the Brightfield/Phase Contrast Condenser ....................  13 
Using Filters..........................................................................  11 

Using the Camera Port ...........................................................  11 

Maintenance 

Aligning the Phase ContrastAnnulus Rings .............................  1 

o

Replacing the Lamp ..............................................................  14 

Replacement lamp Information .............................................  14 
Replacing the Fuses..............................................................  15 

Replacement F use Information .............................................  15 

Caring for your 1400INi Microscope ........................................  16 

Troubleshooting .................................................................... 

18 

Specifications .................................................................. 

19 

Warrantyinforrnationanda registrationcan:I 

canbefoundatthefo1towlngwebaddress: 

4'1:Dspecifications 

Viewing Head: 
Viewing Head Type: 

Head Rotation: 
Head Inclination: 

Sliding Prism: 
lnterpupillary Adjustment: 

Dioptric Adjustment: 
Eyepiece Magnification: 
Eyepiece Field Diameter: 
Nose piece: 

Brightfield Objectives: 
(Plan Achromatic, Infinity Corrected) 

Phase Contrast Objectives: 
(Plan Achromatic, Infinity Corrected) 

Stage Dimensions: 
Stage Motion: 
Stage Movement Range: 
Sample Clearance (Brightfield): 

Focusing Movement: 
Focusing Graduation: 

Brightfield Condenser (1491INi): 

Trinocular 
Seidentopf 
360

° 

30

° 

100% or 80/20% Split 

48-75mm 
-6 to +6

1 OX High Eyepoint,  Ultra-Widefield 

22mm 
Quintuple 
4X 

(0.10 N.A., 25.2mm W.D.] 

10X  (0.25 N.A.,  11mm W.D.] 

20X  [0.25 N.A., 6mm W.D.] 
40X  (0.60 N.A., 3.2mm W.D.] 

10X  (0.25 N.A.,  11mm W.D.] 

20X  (0.25 N.A., 6mm W.D.] 
40X  (0.60 N.A., 3.2mm W.D.] 

160mm x 250mm 

Right-hand Coaxial Control/Rack & Pinion Drive 
78 x 120mm 
75mm [Standard] 

150mm [With condenser lens removed] 

Coaxial Coarse & Fine Controls 
2 microns Per Division 
0.30 N.A. Condenser with Iris Diaphragm 

Phase Contrast Condenser (1493INi): 

0.30 N.A. Condenser with Iris Diaphragm & Annulus Slider 

Phase Centering Tool: 

Telescoping Eyepiece [1493INi only] 

Illumination: 

Fuse: 

Voltage: 

Base Dimensions: 
Overall Dimensions: 

Weight: 

30W, 6V Variable Quartz Halogen 

1A, 250V  (2 ea) 
110V  [Standard], 220V  [Optional] 

320mm x 245mm 
515mm (L) x 300mm (W) x 475mm (H) 

11kg 

19 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Reviews: