5. Using the Enpres
ATTENTION: with the manual controlled Enpres (with a three position switch) the pump
must be started by means of putting the three position switch in the star position. After a
few seconds, the three position switch must be turned from the star position to the delta
position to avoid irreparable damage to the motor (see 5.2 for more information).
5.1 In general
never leave the pump running without fluid and/or oil;
too little oil will cause the pump to overheat and it will be irreparable damaged;
never set the pressure to above the maximum value;
o
see the sticker on the cooling fan cap and the CE sticker on the motor mounting plate for
the maximum value;
keep the pump, the fluid tank, and fluid supply clean;
make sure that before starting the guard is placed and secured to the mounting plate;
check the suction filters and suction lines on a daily base;
for questions and advice the manufacturer can be consulted.
Petrol powered Enpres:
first read the instruction manual of the petrol engine;
use clean petrol;
check filters and motor oil daily.
5.2 Starting
close the bullet valve (21) between pump and press line with the handle (9);
open the handle for pressure free start-up by means of putting it in a vertical position;
check whether the pump is pressure free;
o
the pressure gauge should indicate 0 bar;
check whether the suction filter is clean and intact;
check the oil level.
With manual control;
start the electromotor by means of putting the three position switch (23) in the star position (1
click clockwise);
after 3 seconds turn the three position switch to the delta position (another click clockwise);
wait until fluid comes out of the overflow (20)
bring the pump onto pressure by putting the handle for pressure free start-up (16) to a horizontal
position;
set the desired working pressure by turning the black knob of the pressure regulator (19);
o
a clockwise rotation increases the pressure;
o
a anti clockwise rotation decreases the pressure;
open the bullet valve (21) between the pump and the press line with the handle (9);
o
attention; the desired working pressure is set with closed bullet valve (21)!