INSTALLATION

SECTION 4

MAXIMUM WORKING PRESSURE

MODEL

AC-50 & AC-60
AC-70 THRU AC-110
AC-120 THRU AC-130

70

O

F

525 PSIG
450 PSIG
400 PSIG

300

O

F

460 PSIG
395 PSIG
350 PSIG

400

O

F

435 PSIG
370 PSIG
330 PSIG

FIGURE 2 FLEXIBLE HOSE DETAILS

WEIGHT

2.0 LBS
3.0 LBS
4.5 LBS

DIMENSIONS

A

12"
16"
18"

B

1" NPT

1-1/2" NPT

2" NPT

PART NO.

83-0735
83-0736
83-0737

HOSE

FH-1
FH-1-1/2
FH-2

If the aftercooler is to be installed in an existing piping system, clean
the piping to remove accumulated dirt, pipe scale, oil, and other
contaminants before installing the unit.

A properly sized pressure relief valve should be installed after the
compressor and before any block valves.  The relief valve should be
installed in compliance with any applicable federal, state, or local
codes.

To isolate the aftercooler for maintenance, install bypass piping around
the aftercooler and separator (if installed).  Reference Figure 3.

Connect the inlet piping to the top of the aftercooler.  Make sure that
the flexible hose is properly installed before the aftercooler inlet.
Provide  supports  wherever  necessary  to  prevent  stress  on  the
aftercooler.  Supports should be installed close to the inlet and outlet
manifolds.  Use either overhead or stiff-leg type supports.

4.5  FREEZE PROTECTION

If the aftercooler is to be installed in a location where ambient tempera-
tures may fall below 35

o

F, heat tracing and/or insulation must be used

on the outlet piping to the separator, the separator, and the drain
piping.  The aftercooler must be protected from the direct wind, i.e. a
roof and/or walls.

The aftercooler should be turned off when ambient temperatures  fall
below 35

o

F.

FIGURE 3 RECOMMENDED INSTALLATION DETAIL

4.3 FLEXIBLE HOSE INSTALLATION

IMPORTANT

A FLEXIBLE HOSE MUST BE INSTALLED BETWEEN THE
COMPRESSOR  AND  AFTERCOOLER  TO  VALIDATE  THE
WARRANTY  ON  THE  AFTERCOOLER.

The flexible hose must be installed perpendicular to the direction of
vibration  from  the  compressor.

If a flexible hose was not ordered with the aftercooler, one can be
ordered from your Van Air distributor.  Figure 2 lists the hose required
for each aftercooler model.

4.4 PIPING INSTALLATION

CAUTION

ALL  PIPING  MUST  BE  ADEQUATELY  SUPPORTED  AND
ISOLATED FROM VIBRATION.  EXCESSIVE STRESS OR
VIBRATION IN THE PIPING WILL CAUSE DAMAGE TO THE
AFTERCOOLER  CORE.

TO ENSURE PROPER OPERATION, MAKE SURE THAT THE
INLET  AND  OUTLET  PIPING  ARE  CORRECTLY  CONNECTED
TO THE UNIT.  REFERENCE FIGURE 3.

Summary of Contents for AC-50

Page 1: ...E AFTERCOOLER ABOVE THE MAXIMUM RATED OPERATING CONDITIONS AS OUTLINED IN SECTION 3 1 NEVER REMOVE THE FAN GUARD WHILE THE AFTERCOOLER IS OPERATING CONTACT WITH THE ROTATING FAN BLADE S MAY RESULT IN...

Page 2: ...essures 80 to 125 PSIG Approach Temperature The number of degrees above the temperature of the cooling medium in this case ambient air to which the aftercooler reduces the compressed air A higher appr...

Page 3: ...43 50 43 50 43 50 47 63 51 68 B 46 50 46 50 46 50 46 50 46 50 46 50 46 50 49 50 55 50 C 50 50 50 50 50 50 50 50 50 50 50 50 50 50 53 50 59 50 M 2 17 2 17 2 17 2 17 2 17 2 17 2 79 2 85 2 83 L 18 29 18...

Page 4: ...the aftercooler Supports should be installed close to the inlet and outlet manifolds Use either overhead or stiff leg type supports 4 5 FREEZE PROTECTION If the aftercooler is to be installed in a loc...

Page 5: ...UPPLY AND DISCONNECT Install a properly sized fused disconnect before the aftercooler Make the necessary wire connections and re install the junction box cover 2 INTERLOCKED WITH COMPRESSOR MOTOR STAR...

Page 6: ...PAGE 6 PRINTED IN THE U S A 5 3 REPAIRING LEAKS INSTALLATION SECTION 4 FIGURE 5 WIRING DIAGRAM...

Page 7: ...NCEINSTRUCTIONS WARNING BEFORE STARTING INSTALLATION OR MAINTENANCE PROCEDURES TURN OFF ELECTRICAL POWER AND COMPLETELY DEPRESSURIZE THE UNIT FAILURE TO HEED THIS WARNING MAY RESULT IN SERIOUS PERSONA...

Page 8: ...IGENCE OR STRICT LIABILITY OF BUYER NOT WITHSTANDING THE PROVISIONS OF ANY WORKER COMPENSATION OR SIMILAR STATUTE V SERVICE OPERATING PROCEDURE WARNINGS Should Buyer request start up supervision by Se...

Reviews: