RX-Series

 INSTALLATION GUIDE 

Summary of Contents for Canna+ 400

Page 1: ...Version 2018 1 www valoya com 358 10 2350 300 RX Series INSTALLATION GUIDE ...

Page 2: ...emäße Installation kann zu Personen und Sachschäden führen SVENSKA AKTA Felaktig installation kan leda till skador p per soner och lampan ESPAÑOL PELIGRO Una instalación inadecuada puede provocar lesiones o da ar la lámpara 日本語 注意 不適切な取り付けは人の傷害 およびランプの 損傷の原因となる場合があります NEDERLANDS LET OP Onjuiste installatie kan schade aan personen of de lamp veroorzaken SUOMI HUOMIO Valaisimen huolimaton asennus vo...

Page 3: ...BX C Series 10 Connect LED drivers to electrical branch circuits ensure suitable strain relief is fitted 11 Products with an earth connection must be earthed for safety 12 Installation of additional electrical circuit protection devices is strongly advised Type C MCB s Miniature Circuit Breakers RCD Residual Current Device ICL Inrush Current Limiter SPD Surge Protection Device 13 Do not high volta...

Page 4: ...t the delivery was not delivered in good condition If the packaging shows no damage but the goods inside are either missing defective or show other signs of damage please contact us In all cases please take pictures as evidence and contact us as soon as possible by phone or e mail Check package Check content Check operation If problems contact us PART IDENTIFICATION D Luminaire Mains input mating ...

Page 5: ...tional ambient temperature range C F 10 35 14 95 Maximum Relative Humidity 90 non condensing Storage temperature C F 20 40 4 104 Ingress Protection IP rating IP 55 Impact Protection IK rating IK 03 Cooling method Passive cooled Regulations Approvals CE marked X RoHS compliant X EMC directive compliant X Low Voltage Directive compliant X Eco design EuP directive compliant X Certified to UL CSA stan...

Page 6: ...NS 6 D RX400 A Height incl driver mm in 166 mm 6 5 in B Height mm in 99 mm 3 9 in C Length mm in 347 mm 13 7 in D Width mm in 382 mm 15 in E Screw hole diameter mm in 5 mm 0 2 in F Bolt fitted head size mm in 10 mm 0 4 in F Bolt fitted thread M6 D E Optional hanger fixing points D E D E F ...

Page 7: ...TANDARD HANGER 2X A 46 mm 1 8 in B 22 5 mm 0 9 in C 20 mm 0 8 in D 175 mm 6 9 in E 41 mm 1 6 in F 6 5 mm 0 25 in 4x OPTIONAL HANGER 2X Chain length mm in 500 mm 19 7 in CABLES A Mains cable mm in 300 mm 11 8 in B Dimming cable mm in 300 mm 11 8 in 7 PRODUCT DIMENSIONS D E D ...

Page 8: ... 358 10 2350 300 Version 2018 1 8 Installation Instructions LUMINAIRE ORIENTATION METHOD A STANDARD HANGER METHOD B OPTIONAL HANGER 10 mm spanner Possible carabiner connection points No other orientation is permitted ...

Page 9: ... lamp 3 If dimming is to be used connect a suitably rated 2 core cable not supplied to the pre installed in line Phoenix connector See Phoenix in line connector connection 4 If dimming is to be used connect to the and of a compatible current sink dimmer controller 5 Connect the mains cable to the mains supply Current sink controller Check compatibility 3 2 1 4 5 LUMINAIRE CONNECTION Mains AC conne...

Page 10: ...arth Incoming cable Incoming cable 1 2 3 Phoenix in line connector connection for dimming Connect suitable 2 core cable to the in line Phoenix connector as shown below note images show 3 core cable but an earth is not required for the dimming connection Connect pins 1 and 2 only See also https bit ly 2sZKg5B 1 2 3 4 Remove mating part discard blanking end cap Insert your cable 2 core Connect Pin 1...

Page 11: ... a 16A Type C MCB BX series 6 BL series 16 C series 6 RX series 3 LightDNA 8 2 ICL INRUSH CURRENT LIMITER An ICL can help avoid nuisance MCB tripping and can be installed between the MCB and the load It also enables an increase the luminaire quantity up to the maximum RMS current limit of the Inrush Current Limiter ICL example Use only MCB s with Type C trip characteristics according to EN 60898 w...

Page 12: ...o protect against surge peaks above 4KV e g Due to a lightning strike we recommend the installation of transient voltage surge suppression Do not apply power without the Neutral connected Ensure the supply is off before disconnecting the Neutral To avoid erratic dimming or possible product damage do not connect the same dimmer or controller to luminaires supplied by different mains phases Valoya p...

Page 13: ...dependent Below this the light output is off without the need for mains switching 13 DIMMING POSSIBILITIES BY PRODUCT RANGE BX Series BL Series L Series C Series RX Series 1 10V 0 10V 0 10V DIMMING CONTROL COMPATIBILITY LED drivers used by Valoya comply with International standard for current sink controls IEC 60929 Annex E This specifies that the LED driver is a current source device Compatible c...

Page 14: ...10V Philips www lighting philips com UID8600 00 1 10V Dimmer Priva www priva com RAM www ram group com Siemens www siemens com 5TC8424 Examples of manufacturers of compatible control products systems some example products indicated MANUFACTURERS WEBSITE EXAMPLE PRODUCT 14 Important considerations when choosing a controller Please check with you controller provider regarding the specification of th...

Page 15: ...for erratic dimming performance Luminaire LED Driver Potentiometer AC supply DIM DIM Live L Neutral N Earth E Luminaire LED Driver A B C D Luminaire LED Driver AC supply Live L Neutral N Earth E DIM DIM DIM DIM Dimmer connections A Live Input B Control C Control D Switched Live Output Luminaire LED Driver A B Luminaire LED Driver AC supply Dimmer connections Live L Neutral N Earth E A Control B Co...

Page 16: ...driver related This will speed problem resolution and minimize unnecessary shipping costs Switch off the mains supply Disconnect the luminaire from its LED driver Connect the luminaire to an unpowered working LED driver if available Connect the mains supply to the working LED driver If the problem remains then the luminaire may be damaged If the luminaire now works then the original LED driver or ...

Page 17: ...provide the following information about the issue Product model information e g B200 NS1 Product serial number plus YF or XF code Quantity showing problems Detailed problem description Photograph or video showing the issue if possible Installation invoice date if known After receiving an RMA number Products should be suitably packed and the package or shipping paperwork clearly marked with the RMA...

Page 18: ...ctromagnetic compatibility EMC Part 4 6 Testing and measurement techniques Immunity to conducted disturbances induced by radio frequency fields IEC EN 61000 4 8 Electromagnetic compatibility EMC Part 4 8 Testing and measurement techniques Power frequency magnetic field immunity test IEC EN 61000 4 11 Electromagnetic compatibility EMC Part 4 11 Testing and measurement techniques Voltage dips short ...