Part 590839

ZERO CLEARANCE KIT

for Models 737UN, 737UP & 737BN

INSTALLATION INSTRUCTIONS

1.  GENERAL

This kit must be used when installing heater Model 737UN, 737UP or 737BN into an enclosure constructed of

combustible material. The heater must also be connected to an approved flue pipe.

This kit has been designed to act as a fireplace opening for installation during the construction of  the appliance enclosure.
The heater is designed to be fitted into the opening after the walls and hearth have been finished.

2.  FRAMING.

Minimum clearances to combustible materials and framing details are shown in fig.1,.

Though not mandatory for this appliance, if the bottom of the appliance is at floor level, we recommend that there is a

hard surfaced hearth area in front of the fireplace for both aesthetic and maintenance purposes. This may be finished in

brick, ceramic tile, marble, etc.

To enable the heater to be installed correctly the height of the finished floor surface in front of the appliance
must be known before constructing the frame. The bottom of the zero clearance kit must be installed at the
height of the finished floor surface.

SHELF DEPTH “A”

25mm

50mm

75mm

100mm

125mm

150mm

175mm

HEIGHT FROM BASE OF

HEATER “B”

960mm

1010mm

1040mm

1090mm

1140mm

1190mm

1240mm

600A711/02

 

 Fig.1

 
 Fig. 2