Valor Ultimate 717 Owner'S Manual Download Page 11

FUEL BED REFITTING

1. 

Place the rear base coal in the firebox. It should rest on the ledges at the rear sides of

the burner unit. When located gently
move the rear base coal so that it is as far
forward as possible. The amount of
movement will be negligible (See figure
4).

2.

Place the front base coal in the firebox

with its bottom front locating over the
front rim of the firebox. Pull the coal
forward so that it locates immediately
behind the front rim of the firebox. (See
figure 5).The front base coal will touch
the rear base coal as it is located. 

Pa ge   1 0

OWNER GUIDE

Figure 5. Front base coal position

Figure 4. Rear Base Coal Position

Summary of Contents for Ultimate 717

Page 1: ...LIANCE IS FOR USE WITH PROPANE GAS G31 THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE UNITED KINGDOM GB AND THE REPUBLIC OF IRELAND IE We trust that these instructions give sufficient details...

Page 2: ...st with low interest rates PRICE MATCH always get the best deals available Boilers Radiators Heating controls Pipes ittings Cylinders Fires Renewable energy Bathroom suites Kitchen sinks taps Showers...

Page 3: ...s a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a CORGI registered company All our gas fires mu...

Page 4: ...ED REFITTING 10 MAINTENANCE 12 Regular maintenance 12 Servicing 12 USEFUL TELEPHONE NUMBERS 13 This gas fire is designed to meet the most stringent quality performance and safety requirements to provi...

Page 5: ...the installation instructions Do provide a minimum clearance of 750mm from the top surface of the hearth to any shelf made of wood or other combustible material where the shelf is not more than 150mm...

Page 6: ...become discoloured when close to a heating appliance Please bear this in mind whenever you are considering redecorating Do provide a minimum side clearance as detailed in figure 1 Please bear this in...

Page 7: ...atural gas input of 2 3kW Gross Has a minimum natural gas output of 1 15kW Model 717 when converted using kit number 0595221 Has a maximum propane gas input of 6 1kW Gross Has a maximum propane gas ou...

Page 8: ...by a 4 position gas tap mounted on the front leg of the appliance In addition to the Off position there is a pilot light and 2 heat control settings See figure 2 Depress the control knob and turn ant...

Page 9: ...rations If operating the appliance for long periods it is beneficial to change between settings This will help to remove any carbon deposits that may form during operation Turning the fire back to Pil...

Page 10: ...fibres Excessive exposure to this material may cause irritation to eyes skin and respiratory tract Consequently it is important to take care when handling these articles to ensure that the release of...

Page 11: ...amount of movement will be negligible See figure 4 2 Place the front base coal in the firebox with its bottom front locating over the front rim of the firebox Pull the coal forward so that it locates...

Page 12: ...etween the front and rear base coals as shown in figure 7 The letter B should be upright 5 Place a type A coal between the front and rear base coals with the letter A upright The top of the coal shoul...

Page 13: ...learance of dangerous exhaust fumes In the United Kingdom it is the law that a landlord must have any gas appliance flue and pipework which is situated in a tenant s premises checked for safety at lea...

Page 14: ...nical Helpline 08706 061 065 In the Republic of Ireland call 0044 08706 061 065 for all enquiries USEFUL TELEPHONE NUMBERS General advice about gas and your gas fire VALOR TECHNICAL HELPLINE 08706 061...