Valor Temptrac Instructions For Use Download Page 3

www.valortpms.com

INSTALLATION GUIDE – TEMPTRAC

Truck Diagram

There Are 2 Installation Steps For This Product:

2. TRUCK CAB INSTALLATION

NOTE:  The Transceiver needs to be installed near 

the GO7 Unit.

1. 

 Connect the supplied GO Wire Harness to the 
Transceiver.

2. 

 Connect the other end of the supplied Valor 
Wire Harness to the Geotab IOX-CAN Harness.

3. 

 The Geotab IOX-CAN Harness connects to the 
GO7 device. Connect to the vehicle where indicated.

4. 

Data is communicated over the Geotab IOX-CAN.

5. 

 Route the antenna to the rear of the cab and mount in a 
safe place away from step and pinch points.

Each zone transmits separately:

 

records ever 0.5 degree change

 

records temperature when power is turned on

 

 records every 30 min when temperature is stable

 

 exceptions for temperature threshold are set by vehicle in 
MyGeotab

The Geotab Report can chart temperature 
data in either Celcius or Farrenheit.

My Geotab Reporting

Valor + Geotab Setup

3. REEFER UNIT INSTALLATION

NOTE:  Turn on Sensors prior to installation (back of unit). Sensors are active 

once turned on. In humid environments or where sensor can get wet 
after turning on sensor, use dialectic silicon,or sealant on sensor power 
switch.

6. 

 There is a sensor for each zone and each sensor is assigned to a 
zone. The sensor for zone one is marked 
as such (Zone 1), while the sensor for zone two is unmarked. 
Each sensor has a unique identifier code 
which is pre-programmed into the Transceiver.

7. 

 Install the sensors directly onto the Reefer Zones’ 
inside wall or ceiling using either the supplied velcro or 
with screws (not supplied).

8. 

 The sensors wirelessly transmit data to the Transceiver.

ZONE 1

ZONE 2

Antenna

Sensors

Geotab
GO Device

Transceiver

Reviews: