www.valortpms.com
3
INSTALLATION GUIDE – TEMPTRAC
Truck Diagram
There Are 2 Installation Steps For This Product:
2. TRUCK CAB INSTALLATION
NOTE: The Transceiver needs to be installed near
the GO7 Unit.
1.
Connect the supplied GO Wire Harness to the
Transceiver.
2.
Connect the other end of the supplied Valor
Wire Harness to the Geotab IOX-CAN Harness.
3.
The Geotab IOX-CAN Harness connects to the
GO7 device. Connect to the vehicle where indicated.
4.
Data is communicated over the Geotab IOX-CAN.
5.
Route the antenna to the rear of the cab and mount in a
safe place away from step and pinch points.
Each zone transmits separately:
records ever 0.5 degree change
records temperature when power is turned on
records every 30 min when temperature is stable
exceptions for temperature threshold are set by vehicle in
MyGeotab
The Geotab Report can chart temperature
data in either Celcius or Farrenheit.
My Geotab Reporting
Valor + Geotab Setup
3. REEFER UNIT INSTALLATION
NOTE: Turn on Sensors prior to installation (back of unit). Sensors are active
once turned on. In humid environments or where sensor can get wet
after turning on sensor, use dialectic silicon,or sealant on sensor power
switch.
6.
There is a sensor for each zone and each sensor is assigned to a
zone. The sensor for zone one is marked
as such (Zone 1), while the sensor for zone two is unmarked.
Each sensor has a unique identifier code
which is pre-programmed into the Transceiver.
7.
Install the sensors directly onto the Reefer Zones’
inside wall or ceiling using either the supplied velcro or
with screws (not supplied).
8.
The sensors wirelessly transmit data to the Transceiver.
ZONE 1
ZONE 2
Antenna
Sensors
Geotab
GO Device
Transceiver