11
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information on previous page.
2. Turn the control knob on right side of heater clockwise
to “OFF” position.
3. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell
gas, STOP! Follow “B” in the safety information on previous page. If you don’t smell gas, go to the
next step.
4. Find the pilot. It is in the center below the log.
5. Turn the control knob counterclockwise
to the “PILOT” position. Press in the control knob for
five (5) seconds.
6. With the control knob pressed in, push down and release the ignitor button. This will light the pilot.
If necessary, push down and release the ignitor button several times until the pilot lights. If the pilot
does not light at all during several attempts, try lighting with a long match as described below.
7. Keep the control knob pressed in for about ten(10) seconds then release the knob. The pilot should
remain alight
•
If the pilot lights but will not remain alight after several attempts, turn the gas control knob to
“OFF” and call your service technician or gas supplier.
8. Turn the control knob counterclockwise
to your desired heating level. The main burner should
light. Set the knob to any level between “LOW” and “HIGH”.
Match lighting
: Apply a long match to the pilot while the control knob is depressed and at the “PILOT”
position.
•
If control knobs do not pop up when released after being depressed, stop and immediately call your
service technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
Shutting off completely: Turn control clockwise
to OFF.
Leaving pilot on: Turn control clockwise
to PILOT
.