5

Top of finished 
hearth or floor

Wall Finish

26-1/4”

31-1/2”

to header &

wall finish

(includes 

plinth - 

reduce by

7/8” if not

using plinth)

7-1/2”

minimum
This part of wall 
must be 
non-combustible
(cement board or
similar)

Minimum 

11”

(Allow extra for rear vent elbows)

Top of finished
hearth or floor

Wall Finish

Note: Header
is raised to
accomodate top
vent clearances

39”

to header
(includes
plinth; 
reduce by
7/8” if not
using plinth)

31-1/2

to header

(includes

plinth; 

reduce by

7/8” if not

using plinth)

7-1/2”

 minimum

This part of
wall must be
non-combustible
(cement board
or similar)

Minimum 

11”

26-1/4”

Rear vent framing

Top vent framing

Summary of Contents for President ZC Cast Front 536CXB

Page 1: ...loss of life President ZC Cast Front 536CXB Approved for use with Valor heater model 530 only 2018 Miles Industries Ltd Not compatible with 530INI IPI insert engines HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS DANGER A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for...

Page 2: ...he heater up so the bottom of the heater sits at the finished floor hearth height otherwise the cast front will not sit at the proper height A non combustible hearth is not required in front of this appliance Top Baffle Front Casting with Barrier Screen Rear Base Support Plinth Stand offs 2 Insulation Framing Plate w Brackets Floor Requirements The 530 heater is approved for installation directly on...

Page 3: ... Outlet ZC Stand offs 6 5 8 dia 6 5 8 dia 21 5 8 25 1 4 31 5 7 8 plinth insul 2 26 1 4 20 26 11 9 5 D E Mantel leg See table 2 Mantel depth A Min clearance B Up to 7 4 Above 7 up to 8 5 Above 8 up to 9 7 Above 9 up to 10 8 Above 10 up to 12 9 More than 12 9 extra 1 for every 1 depth above 12 Mantel leg projection D Min clearance from appliance side E Up to 8 0 More than 8 6 Dimensions Clearances ...

Page 4: ... finish and backing required Tighten screws after wall finish to pull brackets tight Cast Front Framing Plate Cover brackets Cover Framing Plate up to holes Wall Finish note any material covering framing plate or within 7 1 2 at top must be non combust non combustible finish backing required Mount Brackets to Heater Install Framing Plate flush with framing or butt drywall to plate and run finish o...

Page 5: ...lar Minimum 11 Allow extra for rear vent elbows Top of finished hearth or floor Wall Finish Note Header is raised to accomodate top vent clearances 39 to header includes plinth reduce by 7 8 if not using plinth 31 1 2 to header includes plinth reduce by 7 8 if not using plinth 7 1 2 minimum This part of wall must be non combustible cement board or similar Minimum 11 26 1 4 Rear vent framing Top ve...

Page 6: ...pacers using the screws just removed 3 Mount the framing plate to the appliance 4 Secure the framing plate and brackets to the sides of the appliance case with 4 thread cutting screws supplied Screw from the outside through the access holes in the framing plate Note There are alternate methods of finishing around the framing plate either leaving it exposed or recessing it and covering it up with th...

Page 7: ...iance front with 2 thread forming screws 6 Install the top insulation layer For top vent outlet appliances cut out a circle at the center of the insulation layer for the vent collar Place the insulation layer on top of the appliance case inboard of the stand off spacers Warning Failure to install the insulation layer may cause a fire hazard and void warranty 7 If the hooks have been shipped loose wi...

Page 8: ...ecorative grille DO NOT lift it by holding the top Always securely replace the window the front and the barrier screen before lighting WARNING FOR YOUR SAFETY ensure the barrier FOR YOUR SAFETY ensure the barrier screen is reinstalled on the fireplace screen is reinstalled on the fireplace after maintenance after maintenance WARNING DO NOT TOUCH THE BARRIER SCREEN DO NOT TOUCH THE BARRIER SCREEN T...

Page 9: ... Baffle 569019 340B252AZ 1 11 Rear Base Support 569079 340B236 1 12 Plinth 569059 350K967 1 13 Framing Plate 4000469 4000469 1 14 Heater Mounting Bracket 4000489 4000489 2 15 ZC Stand off LH 569039 340B235 1 16 ZC Stand off RH 569029 340B234 1 17 Insulation Layer 569049 620B987 2 18 Barrier Screen 4003359 4003359 1 Designed and Manufactured by for Miles Industries Ltd 190 2255 Dollarton Highway North ...

Page 10: ...Devanture de fonte President 536CXB Homologué pour usage avec les foyers Valor Portrait 530 seulement INSTALLATEUR Laissez cette notice avec l appareil CONSOMMATEUR Conservez cette notice pour consultation ultérieure Incompatible avec les foyers encastrables 530INI IPI VITRE CHAUDE RISQUE DE BRÛLURES NE TOUCHEZ PAS UNE VITRE NON REFROIDIE NE LAISSEZ JAMAIS UN ENFANT TOUCHER LA VITRE L écran pare é...

Page 11: ...on locale le permettent Exigences pour la base de foyer Une plinthe de d épaisseur est incluse avec la devanture Cette plinthe permet de soulever le foyer de façon à ce que la devanture de fonte une fois installée soit à la bonne hauteur peu importe la finition du plancher Si la plinthe n est pas utilisée assurez vous que le bas du foyer soit soulevé avec un cale mince pour être égal à la surface d...

Page 12: ...arteurs Dia 6 5 8 Dia 6 5 8 21 5 8 25 1 4 31 5 Plinthe de 7 8 isol 2 26 1 4 20 26 11 9 5 D E Patte du manteau voir table 2 Profondeur A du manteau Dégagement minimum B Jusqu à 7 4 De 7 à 8 5 De 8 à 9 7 De 9 à 10 8 De 10 à 12 9 Plus de 12 9 1 extra pour chaque 1 de profondeur au dessus de 12 Projection D de la patte du manteau Dégagement minimum E du côté de l appareil Jusqu à 8 0 Plus de 8 6 Dimen...

Page 13: ... languettes selon l épaisseur de la finition du mur Détail des languettes Devanture de fonte couvre les supports Matériaux non combustibles seulement au dessus de la plaque d encadrement Plinthe non montrée Encastrement La devanture President ZC 536CXB est fournie avec une plaque d encadrement pour applications à dégagement zéro La plaque d encadrement est peinte en noir et peut être exposée autou...

Page 14: ...cher fini ou de la base de foyer Finition du mur Note La poutre de tête est plus haute pour accomoder les dégagements pour l évacuation par dessus 39 à la poutre de tête plinthe incluse réduisez de 7 8 si vous n utilisez pas la plinthe 31 1 2 à la poutre de tête plinthe incluse réduisez de 7 8 si vous n utilisez pas la plinthe 7 1 2 minimum Cette partie du mur doit être fabriquée de matériau non c...

Page 15: ...s précédemment Mise en garde Le défaut d installer les écarteurs peut créer un risque d incendie 3 Placez la plaque d encadrement sur l appareil 4 Fixez la aux côtés de la boîte de foyer avec 4 vis auto taraudeuses fournies Vissez la plaque de l extérieur à travers les fentes de ses côtés Note Il y a 2 méthodes de finition autour de la plaque d encadrement La plaque peut être exposée ou enfoncée et...

Page 16: ...nstallations à évacuation par le dessus découpez un cercle au centre de l isolant pour faciliter le passage du conduit d évacuation Placez l isolant sur le dessus de la boîte de foyer à l intérieur des écarteurs Mise en garde Le défaut d installer l isolant peut créer un risque d incendie 7 Si nécessaire vissez les crochets à l arrière de la devanture Notez bien que les crochets droit et gauche so...

Page 17: ...NE PAS soulever la devanture par son bord supérieur Toujours remettre la fenêtre et la devanture munie du pare étincelles en place et les fixer solidement avant d allumer le foyer AVERTISSEMENT NE TOUCHEZ PAS LE NE TOUCHEZ PAS LE PARE ÉTINCELLES PARE ÉTINCELLES LA LA DEVANTURE OU LA FENÊTRE LORSQU ILS DEVANTURE OU LA FENÊTRE LORSQU ILS SONT CHAUDS SONT CHAUDS Laissez le foyer refroidir avant de La...

Page 18: ...0 Dessus de fonte 568969 550K065AZ 1 11 Déflecteur d air 569019 340B252AZ 1 12 Support de base arrière 569079 340B236 1 13 Plinthe 569059 350K967 1 14 Plaque d encadrement 4000469 4000469 1 15 Montants pour la plaque 4000489 4000489 2 16 Écarteurs ZC côté gauche 569039 340B235 1 17 Écarteurs ZC côté droit 569029 340B234 1 18 Isolant 569049 620B987 1 19 Pare étincelles 4003359 4003359 1 Conçue et fa...