WARNING
This conversion kit shall be installed by
a qualified service agency in accordance
with the manufacturer’s instructions and
all applicable codes and requirements
of the authority having jurisdiction. If
the information in these instructions is
not followed exactly, a fire, explosion
or production of carbon monoxide may
result causing property damage, personal
injury or loss of life. The qualified service
agency is responsible for the proper
installation of this kit. The installation
is not proper and complete until the
operation of the converted appliance is
checked as specified in the manufacturer’s
instructions supplied with the kit.
Use this manual in conjunction with the
installation manual supplied with the
appliance.
Caution
The gas supply shall be shut off prior to
disconnecting the electrical power, before
proceeding with the conversion.
Model 2700KN
2700KP
Gas
Natural
Propane
Altitude (Ft.)
0-4,500 feet
Input Maximum (Btu/h)
39,000
39,000
Input Minimum (Btu/h)
22,000
20,000
Manifold Pressure (in w.c.)
3.9”
10””
Minimum Supply Pressure (in w.c.)
5”
11”
Maximum Supply Pressure (in w.c.)
10”
14”
Main Burner Injector Marking
DMS#31
DMS#49
Pilot Injector Marking
BL22N
BL14LP
Min. Rate By-Pass Screw
220
150
4009506-02
©2024, Miles Industries Ltd.
This appliance is certified for use from 0–4500 feet. For
altitudes above 4500 feet, see local codes.
Kit Contents
1 Pilot injector
1 Main burner injector
1 Set of conversion labels
1 Minimum rate bypass screw
Tools Required
• Wrenches, to disconnect gas line
• Phillips (+) screwdriver
• Small (jewelers size) flat blade screwdriver, to set
pressure
• Small flat blade screwdriver, to release pressure tap
on valve
• Needle nose pliers, to remove bypass screw
• Allen key, 5/32”, to change bypass screw
• Wrench, 7/16”, to remove pilot hood and injector
• Socket wrench, 7/16”, with extension to change main
burner injector
• Manometer, to set pressure
Speci
fi
cations
2700KNGK / 2700KPGK Gas Conversion Kit
For Valor 2700K
fi
replaces ONLY
INSTALLATION MANUAL
LT2 Series
General Notes Regarding Conversion
The conversion may be done before or after the
appliance is installed into the cavity. However, the gas
must be connected to set the manifold pressure.