all Finish — Avoid Cracking

October 2023

3/3

LT2 2700K

Cracks

Provide joints 

either here or 

here

Avoiding Cracking Wall Finishes

If a clean 

fi

 nish with no tile, etc. is desired, joints in the 

non-combustible board and the transition to gypsum 

board will require special attention if future cracking 

is to be controlled. Be aware that temperatures on the 

non-combustible wall surface above the appliance can 

approach 200°F (93°C). 

Below are some tips on how to best avoid any cracking:

• Allow materials to dry thoroughly before 

fi

 nishing the 

wall. Non-combustible board has the ability to absorb 

up to 30 percent of its weight in water and may shrink 

as much as 1/8” over a 48” length when drying from 

a saturated condition. Running the 

fi

 replace for an 

extended period before 

fi

 nal 

fi

 nishing will help drive 

out moisture.

• Always pre-drill screw holes through non-combustible 

board and use screws with self-milling head.

• Always use mesh tape over joints.

• Always stagger joints in wall board.

• Behind joints, double up studs or use studs “on the 

fl

 at” to add extra support to the joint. Adhesive on 

the backside of wall board behind any joints can help 

control di

 erential movement.

• Use multiple, thinner coats of joint compound and al-

low to dry thoroughly between coats.

• Ensure framing materials are dry.

• After 

fi

 nishing the wall, introduce heat gradually to 

slowly dry any excess moisture rather than drying too 

fast.

• Avoid notching non-combustible board or tiles around 

corners of window opening and instead provide a joint 

that intersects the corner.

• Avoid using large one-piece slab of material with a 

cut-out in the middle as a surround for the 

fi

 replace.

Expansion above the opening will cause cracking at 

inside corners. Provide a joint that intersects the inside 

corner to avoid cracking.

 WARNING:

HeatShift System MUST be installed on this 

appliance.