Valor Heartbeat Oxysafe 426 Owner'S Manual Download Page 4

4

H

OW TO LIGHT YOUR 

V

ALOR GAS FIRE

The control is shown in Figure 1.

 

Depress the control knob and turn partially to the 1/IGN
position until you feel some resistance.

 

Keep the knob depressed at this position for a few seconds to
allow gas to flow to the burner.

 

While keeping the knob depressed, turn to the 1/IGN position.
While turning, a spark should light the pilot.

 

Keep the knob depressed at the 1/IGN position for a further
10 seconds then release it. The centre section of the coal will
be alight at this position.

 

Depress the control knob slightly and turn it to your desired
burner setting.

 

The control knob should be depressed slightly before turning
whenever you are changing the burner setting.

 

The burner settings are;
1/IGN...........Centre section on low. Outer sections off.
2....................Centre section fully on. Outer sections off.
3....................Centre section fully on. Outer sections on low.
4....................Centre section fully on. Outer sections fully on.

 

If the spark ignition fails, the fire can be lit manually by
inserting a lighted taper below the glass window and into the
centre of the coal (as shown in figure 2),  and depressing the
control knob at the 1/IGN position.

 

We recommend that the fire is set at position 4 for the first 10
minutes after lighting to warm up the chimney and so obtain
full efficiency quickly.

Note: 

If the fire goes out while setting the control, repeat the full

lighting procedure. If the fire repeatedly goes out, have the fire
serviced.

H

OW TO TURN OFF YOUR 

V

ALOR GAS FIRE

 

Partially depress the control knob and turn clockwise to OFF. Release the knob.

 

Wait at least 3 minutes after turning the fire off before relighting.

T

HE FLAME SENSING & SPILLAGE MONITORING SYSTEM

 

For your safety, this appliance is fitted with a device which will automatically shut
off the gas supply to the fire if the pilot flame goes out. It will also shut off the gas
supply if the flue is blocked causing spillage of fumes, or if there is insufficient
ventilation to the fire.

 

This device incorporates a probe which senses that the heat from the pilot flame
is correct. If this probe is cool, the device will prevent any gas flow unless the
control knob is kept depressed at the 1/IGN position.

 

If the flames go out, or if for any reason the fire is turned off, always wait at least 3
minutes before attempting to relight.

 

If this device starts to shut off the gas frequently please get expert advice from the
Valor AdviceLine on 0345 626341 (local call rates apply in the United Kingdom).

G

AS 

C

ONSUMPTION

This gas fire has a maximum gas input of 5.77kW (Gross).
The fire has a low setting of 0.8kW (gross) output and a high setting of 3.55kW
(gross) output. To calculate the running cost of this gas fire, multiply the gas
consumption (heat input) by the cost of gas which you will find on your gas bill.

          GAS  

            COST         

 

RUNNING

CONSUMPTION                   OF GAS

   COST

    (HEAT INPUT)

 

PART 2

: OPERATING INSTRUCTIONS

 

 Figure 2 Lighting with a taper

X

=

 

 Figure 1 The Control

Summary of Contents for Heartbeat Oxysafe 426

Page 1: ...r Guide is intended to help you care for your Valor gas fire Please read carefully before using your gas fire and keep for future reference This Owner Guide gives sufficient details to enable your gas...

Page 2: ...dvice about gas in general the Valor AdviceLine will be pleased to help Please telephone 0345 626341 local call rates apply in the United Kingdom FOR OTHER USEFUL TELEPHONE NUMBERS SEE INSIDE BACK COV...

Page 3: ...for any reason Your fire is fitted with a safety device which will automatically shut off the gas supply to the fire if for any reason the flames go out Get advice about the suitability of any wall c...

Page 4: ...he full lighting procedure If the fire repeatedly goes out have the fire serviced HOW TO TURN OFF YOUR VALOR GAS FIRE Partially depress the control knob and turn clockwise to OFF Release the knob Wait...

Page 5: ...ove the window without having to call in a service engineer This allows you to clean the inside of the window To remove the window 1 Unscrew and remove the two knurled screws which are under the outer...

Page 6: ...the outer case DEBRIS IN FLUE CHIMNEY In order to achieve high levels of personal safety and performance efficiency it is essential that the opening at the back i e the flue of the fire is kept clear...

Page 7: ...0345 626341 To report faults or arrange for your fire to be serviced VALOR SERVICE 0121 386 6203 To order spares or for sales information VALOR SALES 0121 386 6260 CALLERS IN THE REPUBLIC OF IRELAND...

Page 8: ...Highest Standards Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a Corgi registered com...

Reviews: