![Valor H6 Series Installation And Owner'S Manual Download Page 41](http://html.mh-extra.com/html/valor/h6-series/h6-series_installation-and-owners-manual_851427041.webp)
41
Remove top outlet (6 screws)
Remove heat shield (2 screws)
If using the top outlet or LDK HeatShift Duct Kit,
discard the shield. If using a rear outlet, keep the shield
to reinstall after converting the top to rear outlet—see
next subsection.
Convert from Top to Rear Outlet
(if required)
This unit is supplied with a top vent outlet which
can be fi eld-converted to a rear vent outlet.
Please note that the rear outlet requires the
installation of the heat shield on top of the heater
case as indicated
unless
fi
tted with optional LDK
HeatShift Duct Kit
.
1. Remove the top outlet collar (6 screws).
2. Swivel the collar and install as a rear outlet (6 screws).
3. Reinstall the heat shield to the top of the appliance
case (2 screws).
Swivel the outlet so
that it is oriented
towards the rear and
reinstall to heater
(6 screws)
Reinstall heat
shield to top
of appliance
(2 screws)
Rear outlet with required heat shield
Installation
Unpack Appliance
Beware of sharp edges! Wear gloves!
1. Remove the cardboard wrapping and the wood
pallet from the appliance and discard.
2. Unpack any loose items from around the appliance.
3. Verify that you have all the components
required for the installation,
including:
- approved non combustible cement board;
-
liners and fuel bed (in separate cartons);
- surround kit with barrier screen;
- venting components and accessories;
- electrical components if installing optional
blower.
Fit Standoff s
The standoff s are supplied fl at on the
fi rebox sides and fi xed at one end.
Swivel up the fl at standoff s, bend
them as shown and fi x the loose end
to the top of the fi rebox.
Remove Heat Shield
Remove the heat shield from the top of the appliance
case (2 screws).
Fold fl at
standoff s
Standoff s installed
Standoff
QUALIFIED
INSTALLER
Summary of Contents for H6 Series