Remote Control Operation

Setting ºC/24-hr or ºF/12-hr clock 

In MAN mode, press and hold   +   

buttons until temperature / clock display 

changes from 
°F / 12-hour              °C / 24-hour

Setting Time

The time display will flash after either:
- installing the battery, or

- pressing    + 
To set the time, press buttons:

  = hour
  = minutes

Press   or wait to go back to MAN.

Modes of Operation

Briefly pressing SET cycles through 

modes of operation.

MAN

 > 

TEMP

 >

TEMP

 > 

TIMER

 > 

MAN

NOTE: Press   or   to reach 

MAN

 mode.

MAN

Manual Mode

Manual flame height adjustment.

TEMP

Daytime Temperature Mode

When pilot is lit, room temperature 

is measured and compared to set 

temperature. Flame height automatically 

adjusts to reach Daytime Set 

Temperature.

TEMP

Night time Setback 

Temperature Mode

When pilot is lit, room temperature 

is measured and compared to set 

temperature. Flame height automatically 

adjusts to reach Night Time Setback 

Temperature.

TIMER

Timer Mode

When pilot is lit, two periods of time 

(P1 and P2) can be programmed to use 

Daytime and Night time temperatures 

at specific times.
Note: Display shows set temperature 

every 30 seconds.

Set the di

 erent parameters when 

they are 

fl

 ashing.

Summary of Contents for GV60BRK

Page 1: ...rebox or beside the wall switch 2 With a sharp object press and hold the receiver s reset button until you hear one short and one long beeps Release the reset button after the second beep For use with...

Page 2: ...hearth SET scrolls through modes and settings OFF returns to set mode turns the burner and WKH SLORW R DUJH DPH EXWWRQ DPHV up sets hours temperature 6PDOO DPH EXWWRQ DPHV GRZQ DQG R VHWV PLQXWHV tem...

Page 3: ...nual Mode Manual flame height adjustment TEMP Daytime Temperature Mode When pilot is lit room temperature is measured and compared to set temperature Flame height automatically adjusts to reach Daytim...

Page 4: ...and P2 must be set in the following order during a 24 hour cycle P1 P1 P2 and P2 Day Time temperature high program period Night Time temperature low program period Default Settings Program 1 P1 06 00...

Page 5: ...eliminating energy consumption during non heating months and limited use The programmed length of inactivity to activate the system is specified by the appliance manufacturer and cannot be altered in...

Page 6: ...tu appuyez et tenez le bouton RESET sur le r cepteur jusqu ce que vous entendiez un court bip et un long bip Rel chez le bouton RESET 3 Dans les 20 secondes qui suivent appuyez sur le bouton de petite...

Page 7: ...2 UHWRXU DX PRGH SU U JO WHLQW OH EU OHXU HW OD YHLOOHXVH RXWRQ JUDQGH DPPH DXJPHQWH OHV DPPHV U JOH O KHXUH HW OD WHPS UDWXUH RXWRQ SHWLWH DPPH U GXLW HW WHLQW OHV DPPHV U JOH OHV PLQXWHV HW OD WHPS...

Page 8: ...es flammes TEMP Temp rature haute Quand la veilleuse est allum e la temp rature est mesur e et compar e la temp rature programm e Les flammes s ajustent automatiquement pour atteindre la temp rature p...

Page 9: ...1 et P2 doivent tre r gl es dans l ordre suivante durant le cycle de 24 heure P1 P1 P2 et P2 p riode temp rature haute p riode temp rature basse R glages par d faut P riode 1 P1 6 h 00 P1 8 h 00 P rio...

Page 10: ...e permet au consommateur d conomiser en liminant automatiquement la consommation d nergie durant les mois sans chauffage et d utilisation limit e La dur e de la p riode d inactivit du syst me est sp c...

Reviews: