background image

1

June 2019

Remote Control Initial Pairing

The receiver and the handset of the remote control 
system must be initially paired before the 

fi

 rst use. 

(Note that batteries must already be installed in the wall 
mounted battery holder)

1.  Insert two 1.5 V AAA 

alkaline

 batteries in the handset.

2.  Locate the Reset button on the front side of the re-

ceiver.

3.  With a thin object, press and hold the receiver’s RESET 

button until you hear one short and one long beeps. 
After the second beep, release the reset button.

4.  Within the subsequent 20 seconds, press and hold the 

 button on the remote handset. 

 will be dis-

played on the handset during the pairing sequence. 
You will hear two short beeps con

fi

 rming the pairing 

is done. 

If you hear one long beep, the pairing sequence has failed 
or the wiring is incorrect.

This is a one time pairing only and is not required when 
changing the batteries of the handset or battery holder. 
The remote control system is now ready to use.

Valor 10 Electronic Ignition Remote Control System

For use with Valor heaters model 1500, 1600, 1700, 1800, 2100 and 2200K

OPERATING INSTRUCTIONS

GV60 SYMAX

©2019, Miles Industries Ltd.

Radio Frequency

918.0 MHz for USA and Canada.

This device complies with Part 15 of the FCC Rules 
and with Industry Canada license-exempt RSS 
standard(s). Operation is subject to the following 
two conditions:

(1) this device may not cause harmful interference, 
and

(2) this device must accept any interference 
received, including interference that may cause 
undesired operation.

Reset button

RESET

Summary of Contents for GV60 SYMAX

Page 1: ...ar two short beeps confirming the pairing is done If you hear one long beep the pairing sequence has failed or the wiring is incorrect This is a one time pairing only and is not required when changing the batteries of the handset or battery holder The remote control system is now ready to use Valor 10 Electronic Ignition Remote Control System For use with Valor heaters model 1500 1600 1700 1800 21...

Page 2: ... off AM ON OFF PM AM Mode Thermostatic Mode Signal Indicator Child Proof Light Fan if included Program Mode Temperature Time Auxiliary Feature not used Countdown Timer Battery Status Eco F or C To Turn On Fire One Button lighting default Two Button lighting simultaneously Press and hold for 4 seconds until 8 short beeps and a blinking series of lines confirms the start sequence has begun Release bu...

Page 3: ... To deactivate functions 1 Install batteries All icons are displayed and flashing 2 While the icons are flashing press the relevant func tion button and hold for 10 seconds 3 The function icon will flash until deactivation is com plete Deactivation is complete when the function icon and two horizontal bars are displayed Note If a deactivated button is pressed there is no function and the two horiz...

Page 4: ...works in Manual Thermostatic and Eco modes Maximum countdown time is 9 hours and 50 minutes Light Dimmer Operation On Press is displayed Light is on at preset level Off Press disappears Light turns off Setting 1 Press and hold until flashes 2 To adjust light between 20 100 press or 3 To confirm setting either press or wait is displayed Note The light works independently of the pilot flame If you wa...

Page 5: ...ill display APP Manual Mode The on off status of the fireplace as well as flame height are manually controlled by the user PM ON OFF PM PM Thermostatic Mode On Press is displayed Preset temperature displays briefly followed by the room temperature Setting Desired Temperature 1 Press and hold until is dis played and set temperature flashes 2 To adjust set temperature press or 3 To confirm press or w...

Page 6: ...ss ON ON Off Time Setting PROGRAM 1 1 1 OFF are displayed ALL is displayed briefly Hour flashes 2 To select hour press or 3 To confirm press 1 OFF are displayed ALL displayed briefly Minutes flash 4 To select minutes press or 5 To confirm press Note Either continue to PROGRAM 2 and set ON and OFF times or stop programming at this point and PROGRAM 2 remains deactivated Note PROGRAM 1 and 2 use the...

Page 7: ... 9 hours and 50 minutes CAUTION Do not use a screwdriver or other metallic object to remove the batteries from the battery holder or the handset This could cause a short circuit Low Battery Receiver With low battery power in the battery holder the system shuts off the fire completely This will not happen if the power is completely interrupted Seven Day Shut Off The system shuts off the fire complete...

Page 8: ...sed polarity in thermocouple wiring F06 F06 4 sec 3 failed ignition sequences in 5 minutes Fire is not responding no pilot flame No gas supply Air in pilot supply line No spark Reversed polarity in thermocouple wiring Incorrect pilot orifice if valve has been converted from LPG to NG or vice versa F07 Low battery symbol Permanent Battery icon flashes on handset display Low battery in handset F09 F...