Valor BR622 Owner'S Manual Download Page 7

USERS INSTRUCTIONS

3.

CLEANING

Turn the fire off and allow it to cool before
attempting any cleaning. Note that the fire will

retain heat for some time after it has been

turned off.

If large pieces of debris are found anywhere
in the fireplace, have the chimney inspected
before further use.

Metal parts

Clean the metal parts with a slightly damp
cloth and then dry. Do not use abrasive
cleaners, they could scratch the surface.

Coals and burner compartment walls

This product uses a fuel effect pieces and

burner compartment walls containing

Refractory Ceramic Fibres (RCF), which are
man-made vitreous silicate fibres. Excessive

exposure to this material may cause

temporary irritation to eyes, skin and

respiratory tract. Consequently, it makes

sense to take care when handling these
articles to ensure that the release of dust is
kept to a minimum.

Light coatings of soot will usually be burnt off
during the normal operation of the fire. Should

any soot accumulation become excessive, the
fuel effect pieces and walls should be

removed from the fire for cleaning. Cleaning

should be carried out in a well ventilated area
or in the open air by gently brushing with the
pieces held away from your face so that you
avoid inhaling the dust. We do not
recommend the use of a normal domestic

vacuum cleaner which may blow
dust back into the air. We suggest that you

remove the coals in the reverse order to that

shown in the fuel bed refitting instructions

.

Ceramic burner

Remove any deposits of soot or other foreign
matter from the solid areas of the burner with

a dry soft brush. Be careful not to brush any
particles into the open slots. Remove any
particles from the slots with a vacuum cleaner
fitted with a soft brush attachment.

00

not

poke wire, etc. into the slots in the burner.

4.

FUEL BED REFITTING

If the fuel bed components are dislodged or
removed, they must be refitted as follows

:

Only the fuel bed parts supplied with this

appliance or authorised Valor replacements
must be used

.

Never add extra coals above the

number stated in these instructions

.

1 Place the ceramic base coal in the burner

compartment. The bottom rear face of the co

a

l

should rest on the angled ledge at the back of

the burner compartment. The bottom front

recessed edge of the coal base should locate

against the step in the burner plaques (See
figure 4)

.

(Installer - Note that the small round ho

l

es in

~

the burner plaques which will be covered by
the base coal are not gas burner ports

.

They

are simply a consequence of the plaque

manufacturing process).

Page 7

Summary of Contents for BR622

Page 1: ...S G31 THIS APPLIANCE IS FOR USE IN THE UNITED KINGDOM GB AND THE REPUBLIC OF IRELAND lE ONLY This Owner Manual is intended to help you care for your Valor gas fire Please read carefully before using y...

Page 2: ...tish Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a Corgi registered company All our gas fires must be installed by a competent C...

Page 3: ...E Thank you for choosing Valor All Valor gas fires are designed to meet the most stringent quality performance and safety requirements to provide our customers with many years trouble free service You...

Page 4: ...at least 12mm thick Its top some time after it has beenswitched off surface should be 50mm above floor level to 9 Never hang clothing towels or any other fabrics over discourage placing carpets the fi...

Page 5: ...e if the pilot flame goes out due to lack of oxygen or for any other reason 1 622mm 11 57m Min to corner wall either side COfllroJ s ide butt Control slide bullon If this device starts to repeatedly s...

Page 6: ...e If the flames repeatedly go out have the fire serviced ii Please note When first turned on the flames will appear predominantly blue The coals will take time to warm up Although some glow will be se...

Page 7: ...pieces held away from your face so that you avoid inhaling the dust We do not recommend the use of a normal domestic vacuum cleaner which may blow dust back into the air We suggest that you remove th...

Page 8: ...figure 6 3 2 Place a medium size coal behind and approximately midway between the two front loose coals which are to the left of centre Similarly place another medium size coal behind and between the...

Page 9: ...gdom it is the law that a landlord must have any gas appliance flue and pipework which is situated in a tenant s premises checked for safety at least every twelve months by a competent person In the U...

Page 10: ...NE NUMBERS To help us quickly help you please try to have the following information available before you contact us a Your Post Code b Type of fire c Model Name d Serial Number e The fault problem or...

Reviews: