SHORT LIST OF SPARES

Key

Description

No. Off

Part No.

A

Pilot Injector SIT Ref 0.977.113 (Stamped ‘27’)

1

524949

B

Electrode Pin SIT Ref. 0.007.243

1

524979

C

Thermocouple SIT Ref. 0.290.198

1

524999

D

Main Burner Injector Bray Cat 960/240

1

551079

E

Decorative Burner Injector Bray Cat 960/130

1

525059

F

Gas Tap & Piezo Unit Copreci 21400/88

1

525069

G

Piezo Generator - Copreci 18600 Twin Spark 250mm Lead

1

525339

H

Main Burner

1

525119

J

Decorative Flame Burner

1

525129

K

Window Unit

1

525159

L

Control Knob

1

525199

M

Coal Bed Base

1

525259

N

Coals - Set of 4

1

525269

P

Inlet elbow

1

532519

                          

For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected] 0844 556 1818   

Summary of Contents for Black Beauty Unigas II

Page 1: ...a n t C o n v e c t o r G a s F i r e Black Beauty Unigas II I N S T A L L E R G U I D E Please keep in a safe place for future reference For latest prices and delivery to your door visit MyTub Ltd ww...

Page 2: ...2 600A742 02 For latest prices and delivery to your door visit MyTub Ltd www mytub co uk info mytub co uk 0844 556 1818...

Page 3: ...341 In UK local call rates apply This appliance is for use with natural gas G20 This appliance is for use in the United Kingdom GB and the Republic of Ireland IE only P l e a s e l e a v e t h i s I n...

Page 4: ...13 Final Checks User Instruction 13 Servicing 14 Outer Case Removal 14 Window Unit Removal 14 Ceramic Fuels Removal 14 Burner s Removal 14 Injector s Removal 14 Thermocouple Removal 14 Electrode Pin...

Page 5: ...nsure that the release of fibres from these RCF articles is kept to a minimum during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust and soot accumulated...

Page 6: ...mm of added projection 2 8 There is no restriction on the depth of non combustible projections but a space of at least 30mm should be allowed above the top of the appliance to enable removal of the ca...

Page 7: ...emove 4 4 Remove the window unit by detaching the 12 wing nuts securing the window frame see fig 3 and pulling forward 5 PREPARE THE WALL The flue must be installed so that it is at right angles to th...

Page 8: ...l of the flue unit easier it is recommended that a cardboard cylinder is formed around the flue unit and inserted in the hole while making good Remove the cardboard cylinder after making good 5 7 Rech...

Page 9: ...lows 6 6 1 Using a suitable metal cutting drill bit drill through the outer flue tube and outer spigot at a distance of between 6mm 7mm from the cut end of the outer flue tube See figure 8 6 6 2 Fit t...

Page 10: ...the electrode wire from the pilot unit and place the end of the wire close to a bright metal part of the appliance 8 4 Operate the control again keeping your hand away from the end of the wire If the...

Page 11: ...e the front right coal embossed B underneath in position The flat bottom front face of the coal should rest on the metal ledge immediately behind the bottom front of the firebox opening Slide the coal...

Page 12: ...front of the firebox opening See figure 13 10 4 Close any gap between the two front coals by sliding them together to meet at the centre 10 5 Place the rear right coal embossed D underneath in positio...

Page 13: ...ion has been achieved keep the control knob depressed for a few seconds then release it If the pilot does not remain alight ensure that the air has been purged 11 4 Partially depress the knob and turn...

Page 14: ...range of settings 14 2 Instruct the user on the correct operation of the fire and especially advise that 14 2 1 The fire has a pilot To light the pilot the control knob must be depressed and turned to...

Page 15: ...above 15 5 2 Release the pipe compression fitting s to the injector s 15 5 3 Loosen the pipe compression fitting s to the tap and move the pipe s clear 15 5 4 Remove the injector s and carrier s from...

Page 16: ...s in the off position 15 10 3 Remove the circlip holding the piezo unit to the tap Remove the piezo unit 15 11 To Grease The Control Tap 15 11 1 Detach the tap and remove the piezo generator as 15 10...

Page 17: ...ecorative Burner Injector Bray Cat 960 130 1 525059 F Gas Tap Piezo Unit Copreci 21400 88 1 525069 G Piezo Generator Copreci 18600 Twin Spark 250mm Lead 1 525339 H Main Burner 1 525119 J Decorative Fl...

Page 18: ...ndustries which works to ensure high standards of safety quality and performance Careful Installation Valor is a Corgi registered company All our gas fires must be installed by a competent Corgi Regis...