To Light the Fire

The pilot must be lit using the pilot burner knob on the appliance (see figure 2).
The heat and flame settings can be controlled by either using the main burner control
knob on the appliance (see figure 2) or by using the remote control handset (See figure
4). The remote control handset operates by sending an ultrasonic beam. The handset
does not need to be accurately pointed directly at the fire.

Please note: Research has shown that the ultrasonic transmission signal will not cause
any pain or hearing damage to a domestic cat or dog but it may disrupt its normal
behaviour. We, therefore, do not recommend pointing the remote control handset at
any domestic animal or operating the device within one meter of the animal’s ear.

To light the pilot

1.

Depress the pilot burner control knob and turn anti-clockwise to the ignition

position (

2

 in figure 2) to activate the piezo ignition system. A ‘click’ will be heard and

the pilot should light. Observe if it is alight by looking through the slots to the left
hand end of the front coals. If the pilot does not light immediately, repeat the above
procedure, keeping the knob depressed for several seconds in order to purge any air
from the system.
If after ten seconds, ignition has not occurred, turn the control knob back to the OFF
position. Wait 30 seconds and then repeat the ignition procedure.

2.

When the pilot is alight keep the knob depressed for ten seconds. This will

prevent the flame-sensing device from shutting off the gas while its probe warms up as
explained above.

3.

Release the knob. When the knob is released, the pilot should remain alight. If

the pilot fails to remain alight, repeat the ignition procedure, this time keeping the
knob depressed for a longer period of time.

If the pilot flame repeatedly goes out have the fire serviced.

To light the main burner
Once the pilot light is alight and stable, light the main burner by turning the pilot
burner control knob anti-clockwise to the “main burner on” position  (

3

 in figure 2).

To select the heat and flame setting
a)

Using the appliance manual control:

Turn the main burner control knob to

any desired setting between low (

4

 in figure 2) and high (

5

 in figure 2).

b)

Using the remote control handset: Press the “lower” or “higher” button to any

desired setting.

Summary of Contents for Bauhaus 32-032-60

Page 1: ...H PROPANE GAS G31 THIS APPLIANCE IS FOR USE IN THE UNITED KINGDOM GB AND THE REPUBLIC OF IRELAND IE ONLY This guide is intended to help you care for your gas fire Please read thoroughly before using a...

Page 2: ...The manufacturer is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation The manufacturer is a CORGI registere...

Page 3: ...eplacement Remote Control Receiver 15 Battery Replacement Remote Control Handset 15 Regular maintenance 16 Owner Replaceable Parts 16 This gas fire is designed to meet the most stringent quality perfo...

Page 4: ...ordance with the latest edition of the Gas Safety installation use Regulations In the Republic of Ireland installation must be in accordance with all national and local regulations in force Do have th...

Page 5: ...he suitability of any wall covering near your fire Soft wall coverings e g embossed vinyl etc which have a raised pattern are easily affected by heat They may therefore scorch or become discoloured wh...

Page 6: ...t of 6 95kW Gross Has a minimum gas input of 4 8kW Gross Has a maximum gas output of 3 8kW Gross The LPG Gas appliance Converted using kit no 9500376 Has a maximum propane gas input of 6 2kW Gross Has...

Page 7: ...n the event of abnormal flue conditions This device is NOT a substitute for an independently mounted Carbon Monoxide detector The device will also automatically shut off the gas supply to the fire if...

Page 8: ...allowing it to spring to the minimum setting See figure 3 We recommend that the aeration control is always set at the maximum aeration for at least the first 15 minutes to allow the appliance to effic...

Page 9: ...nd of the front coals If the pilot does not light immediately repeat the above procedure keeping the knob depressed for several seconds in order to purge any air from the system If after ten seconds i...

Page 10: ...goes out Turn the main burner control knob fully clockwise Turn the pilot burner control knob to the ignition position 2 in figure 2 Note that the remote control handset will not operate with the pil...

Page 11: ...take care when handling these articles to ensure that the release of dust is kept to a minimum Light coatings of soot will usually be burnt off during the normal operation of the fire Should any soot...

Page 12: ...drop behind the two square flanges at the top of the rear legs Ensure that the matrix sits flatly on the top of the burner 3 Position the dress coals There are 4 square coals 2 finger coals and 15 ran...

Page 13: ...one at each end of the front row of coals as shown in figure 9 Make sure that they bridge across from the front coal to the matrix 3 4 Take six random shaped coals and position as shown in figure 10...

Page 14: ...random coals and position in the centre of the matrix spaced 10 15mm from each other to make the third row See figure 11 Discard the two remaining random coals 3 6 Finally take the three remaining sq...

Page 15: ...ocation box at the bottom right side of the fire see figure 13 Slide open the receiver unit cover Replace with new batteries fitting the firmly to the connectors Replace the receiver cover Refit the r...

Page 16: ...months by a competent person In the U K a CORGI registered installer We recommend that all gas appliances and their flues wherever situated are checked annually If you require your fire to be serviced...