Avoid upper body/top heavy bending. Do not lean forward or sideways whilst
handling the stove.
-
Always grip with the palm of the hand. Do not use the tips of fingers for support.
-
Always keep the stove as close to the body as possible. This will minimise the
cantilever action.
-
Use gloves to provide additional grip.
-
Always use assistance if required.
2. APPLIANCE DATA AND EFFICIENCY
General information.
*
When converted using kit 0591011.
The appliance information label is located on a plate at the base of the stove.
Efficiency.
The efficiency of this appliance has been measured as specified in BS EN 613 and
the result is as below :
Model
Efficiency % (Gross)
910
73.1
910 when converted to LPG.
73.1
Page 6
©
GDC Group Ltd. 2014
Gas
Natural (G20)
Propane (G31) *
Inlet Pressure
20mbar
37mbar
Input - Max. (Gross)
5.50kW (18,766Btu/h)
5.4kW (18,425Btu/h)
Input - Min. (Gross)
2.3kW (7,850 Btu/h)
3.8kW (12,965Btu/h)
Inlet Test Pressure (Cold)
20.0 ± 1.0mbar
(8.0 ± 0.4in w.g.)
37.0 ± 1.0mbar
(14.85 ± 0.4in w.g.)
Gas Connection
8mm pipe
8mm pipe
Burner Injector
Cat 82 - 065
Size 116
Pilot
Copreci Ref. O.D.S
21500/212
Copreci Ref. O.D.S
21500/212 Fitted with RBM
180 -02 injector
Ignition
Piezo Electric. Integral with
Gas Tap
Piezo Electric. Integral with
Gas Tap
Aeration
See page 18
Non-adjustable
INSTALLER GUIDE