background image

Model

 

785KLN 785KLP

Gas

Natural Propane

Altitude (Ft.)*

0-4,500 feet*

Input Maximum (Btu/h)

28,000

28,000

Input Minimum (Btu/h)

17,500

13,000

Manifold Pressure (in w.c.)

3.2

10.5

Minimum Supply Pressure 

(in w.c.)

5.0

11.0

Maximum Supply Pressure 

(in w.c.)

10.0

14.0

Main Burner Injector Marking

850

300

Pilot Injector Marking

51

30

Min. Rate By-Pass Screw

220

125

Legend G4

4006431-01

©2017, Miles Industries Ltd.

Gas Conversion Kit

785KNGK & 785KPGK

Installation Instructions

This appliance is certifi ed for use from 0–4500 feet. For 
altitudes above 4500 feet, see local codes.

Kit Contents

1 Pilot injector
1 Main burner elbow injector
1 Set of conversion labels
1 Minimum rate by-pass screw

Tools Required

•  Wrenches, to disconnect gas line
•  Phillips (+) screwdriver, to remove burner module
•  Small (jewelers size) fl at blade screwdriver, to set 

pressure

•  Small fl at blade screwdriver, to release pressure tap 

on valve

•  Needle nose pliers, to remove by-pass screw
•  Hex (Allen) wrench, 4 mm or 5/32”, to remove pilot 

injector

•  Manometer, to set pressure, regulator is integral with valve

Specifi cations

Use with with 

Valor Models 785K Heaters ONLY

WARNING

This conversion kit shall be installed by 
a qualifi ed service agency in accordance 
with the manufacturer’s instructions and 
all applicable codes and requirements of 
the authority having jurisdiction. If the 
information in these instructions is not 
followed exactly, a fi re, explosion or pro-
duction of carbon monoxide may result 
causing property damage, personal injury 
or loss of life. The qualifi ed service agency 
is responsible for the proper installation of 
this kit. The installation is not proper and 
complete until the operation of the con-
verted appliance is checked as specifi ed in 
the manufacturer’s instructions supplied 
with the kit.
Use this manual in conjunction with the 
installation manual supplied with the 
appliance.

Summary of Contents for 785KNGK

Page 1: ...sure Small flat blade screwdriver to release pressure tap on valve Needle nose pliers to remove by pass screw Hex Allen wrench 4 mm or 5 32 to remove pilot injector Manometer to set pressure regulator is integral with valve Specifications Use with with Valor Models 785K Heaters ONLY WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s inst...

Page 2: ...pull the burner up 5 Locate shut off valve and isolate then remove 6 screws holding access panel in place 6 Using two wrenches disconnect inlet to valve control 7 Remove remaining screws holding module plate to side wall of firebox and two screws fastened to base 8 Withdraw module from firebox 9 Supporting injector elbow unlock and remove pipe assembly remove injector locknut from inside manifold hou...

Page 3: ...down on it Ensure that it snaps into position Re assemble the module 1 To re install is a reversal of the procedure 2 Position and locate module in the firebox Be careful not to trap cables between firebox and module 3 Secure module to firebox with previously used screws 4 Reconnect gas inlet to valve tightening pipe connection Open shut off valve and inspect 5 Test for leaks by applying a liquid dete...

Page 4: ...ressure Decreases pressure Manifold Pressure Test Tap Valve Inlet Pressure Loosen screw to check tighten afterwards Pressure Test Tappings 5 Turn off the appliance remove the manometer and tighten the test tapping screw Check for leaks 6 Complete the required details of label This appliance was converted on by position along with the label This control has been converted onto the inside face of the...

Page 5: ... maximal Btu h 28 000 28 000 Apport minimal Btu h 17 500 13 000 Pression d admission en c e 3 2 10 5 Pression d alimentation minimum en c e 5 0 11 0 Pression d alimentation maximum en c e 10 0 14 0 Injecteur brûleur principal 850 300 Injecteur de veilleuse 51 30 Vis d indice minimum 220 125 AVERTISSEMENT Ce kit de conversion doit être installé par une agence de service qualifiée selon les directive...

Page 6: ...rrêt isolez le raccord enlevez la 6 vis retenant la plaque d accès en place 2 Utilisez deux clés pour débrancher la conduite de gaz reliée à la soupape 3 Enlevez les autres vis retenant la plaque du brûleur au côté et à la base de la boîte de foyer 4 Sortez la plaque du foyer 5 En supportant l injecteur coude débranchez la conduite et enlevez l écrou de verrouillage de l injecteur de l intérieur d...

Page 7: ...le nouvel injecteur et serrez le Réinstallez la plaque du brûleur 1 Procédez à l inverse pour réinstaller la plaque du brûleur 2 Placez la plaque du brûleur dans la boîte de foyer insérant la soupape en premier Faites attention de ne pas coincer les câbles et fils entre le fond de la boîte de foyer et la plaque du brûleur 3 Fixez la plaque du brûleur avec les 8 vis enlevées plus tôt 4 Rebranchez la...

Page 8: ...sultez le guide d installation du foyer pour réinstal ler les bûches du foyer ou pour continuer l installation Apposez les étiquettes de conversion 1 Complétez les informations requises sur l étiquette Cet appareil a été converti le par 2 Apposez l étiquette d indices signalétiques et l étiquette de conversion au verso de la carte de directives d allumage roulée à la droite de la boîte 3 de foyer ...