WARNING

DO NOT ATTEMPT TO TOUCH THE DATA CARD 

WHILE THE FIREPLACE IS STILL HOT! 

Let the 

fi replace cool fi rst before touching it.

!

 Operating Your Fireplace for the First Time

When operating your new fi replace for the fi rst time, 

some  vapors may be released due to the burning of 

curing compounds used in the manufacture of the 

appliance. They may cause a slight  odor and could 

cause the fl ames to be the full height of the fi rebox, or 

even slightly higher, for the fi rst few hours of operation.
It is also possible that these vapors could set off  any 

smoke detection alarms in the immediate vicinity. 

These vapors are quite normal on new appliances. We 

recommend opening a window to vent the room. After 

a few hours use, the vapors will have disappeared and 

the fl ames will be at their normal height.

Flame Supervision Device

For your safety, this appliance is fi tted with a fl ame 

supervision device which will shut-off  the  gas supply 

if, for any reason, the pilot fl ame goes out. This device 

incorporates a fi xed probe, which senses the heat 

from the pilot fl ame. If the probe is cool, the device will 

prevent any gas fl ow unless manually lighting the pilot. 

See full lighting instructions on page 11 of this manual.

Introduction

Thank You ...

For purchasing a Valor by Miles Industries. Your new 

radiant gas heater is a technical appliance that must 

be installed by a qualifi ed dealer. Each Valor fi replace 

is fully tested during the production process for your 

safety and comfort.

Your unit has been professionally installed by:
Dealer Name: ________________________________
Phone Number :_______________________________

Should you encounter an operational problem, call 

your dealer immediately.
Do not try to repair the unit as you may cause an 

injury or damage the fi replace.

Locating Fireplace & Lighting Information Card

The Fireplace and Lighting Information card is located 

under the fi rebox.
To access the plate, remove the access panel, grab 

the card and slide it out to read it. There is important 
information on both sides of the card.

 

739MN

FOR NATURAL GAS    POUR LE GAZ NATUREL

750

24,000

6,500

3.2"

5.0"

4006176N/01

CIRCULATING FAN KIT 755CFK     VENTILATEUR POUR CIRCULATION D'AIR 755CFK

#4003360-741, #4003293-742, #4003313-745, #4003426-765, #4004666 772

   120V, 60Hz, LESS THAN 1A

   120V, 60Hz, MOINS DE 1A

739N 10000

Fireplace 

model
Serial 

number

 Performance of propane gas appliances may be 

aff ected by the quality of commercial gas sup-

plied in your area.

OWNER’S 

INFORMATION

Summary of Contents for 739-72ILN

Page 1: ...droom or bed sitting room INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Please read this manual BEFORE installing and operating this appliance INSTALL...

Page 2: ...Check ignition spark 29 Check Operation 30 Adjust Aeration if necessary 30 Install Handset Wall Holder 30 Install Front and Barrier Screen 31 Approved Venting Components 32 Warranty 33 Spare Parts 34...

Page 3: ...s Clothing or ammable material should not be placed on or near the appliance This unit must be used with a vent system as de scribed in this installation manual No other vent sys tem or components may...

Page 4: ...sk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at risk individuals a safe distance from the replace Keep the remote control handset...

Page 5: ...ss window Do not let children touch the glass or any parts of your replace even after it is turned o as it is still hot Use the barrier screen provided with the trim or a gate to reduce the risk of se...

Page 6: ...g the pilot See full lighting instructions on page 11 of this manual Introduction Thank You For purchasing a Valor by Miles Industries Your new radiant gas heater is a technical appliance that must be...

Page 7: ...rn o gas supply and call your dealer for service assistance How to Ensure Your Fireplace Cannot Be Turned ON Inadvertently The best way to ensure your replace will not turn on is to turn it o includin...

Page 8: ...splay press on the AUTO button while the display ashes 4 Let go and wait until the ashing stops The remote shows the time you set It also shows the current temperature Setting the temperature Use this...

Page 9: ...urn o when you leave 5 Press the TIMER button and hold it until P2 appears and ashes Let go While ashing push the buttons hour and minutes to set the time at which you want your replace will turn back...

Page 10: ...Conversion propane gas Other accessories 755CFK Circulating Fan Kit 759EBL Enamel Liners 760CBL Ceramic Black Fluted Liners 4001515 Valor Red Brick Set Hearth Gate Hearth gates such as Cardinal s Vers...

Page 11: ...above 2 Set the flame adjustment knob as far clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed in partially Do no...

Page 12: ...of the ame safety system Pilot or Flame recti cation device 4 Inspect and ensure the lighting of the main burner occurs within 4 seconds of the main gas valve opening Visual inspection should match th...

Page 13: ...to ceramic glass and should be avoided Our dealers have had good results from the products listed below We cannot however guarantee the results of these products Brasso Polish Plus by Kelkem Cook Top...

Page 14: ...d 7 Reinstall the front and barrier screen WARNING F O R S A F E T Y P U R P O S E ensure the barrier screen is re installed on the replace front after maintenance Servicing Maintenance Hot Glass Plat...

Page 15: ...om appliance to appliance depending on the type of installation and climatic conditions The appliance area must always be kept clear and free from combustible materials gasoline and other ammable vapo...

Page 16: ...t of the valve under the rebox It is retained by a Velcro tab Grab the receiver and pull it out from its location CAUTION DO NOT USE a screwdriver or other metallic object to remove the batteries from...

Page 17: ...et 1 370 m in USA installations must be in accordance with the current ANSI Z223 1 and or local codes having jurisdiction Heating value of gas in some areas is reduced to compensate for elevation cons...

Page 18: ...id wood ooring in front of the replace if allowed may shrink during the heating season due to heat WARNING Some materials or items although safe may discolor shrink warp crack peel and so on because o...

Page 19: ...uter Trim or Surround sold separately X Y Dimensions Cavity Check that masonry step does not interfere with install dimensions or vent pipe If mantel is combustible see section Clearances for allowabl...

Page 20: ...ial that can ignite and burn whether ame proofed or not or plastered or unplastered Non combustible materials Material which will not ignite and burn Such materials are those consisting entirely of st...

Page 21: ...ermination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vertical height 10 ft measured to bottom of termination Maximum horizontal run 4 ft measured center to...

Page 22: ...appliance 3 Check that you have everything 4 Clean cavity chimney ash dump and clean out 5 Install venting pipes 6 Attach conversion plate to existing replace 7 Install and test fan blower if used 8 F...

Page 23: ...ttom of the rebox The access hole must be plugged with non combustible insulation after the gas supply line has been installed See Dimensions section for detailed location of gas inlet Also take into...

Page 24: ...side in a safe place to avoid damage Install Fan if used If the 755CFK Circulating Fan Kit blower is to be installed we suggest that you do it now The fan cavity is accessible from the back of the reb...

Page 25: ...back of the rebox 3 Apply RTV sealant to the collars on the vent slider and t the two liners ensuring that the exhaust liner is connected to the identi ed EXHAUST vent collar Secure with 4 tapping sc...

Page 26: ...pply piping system by closing its equipment shut o valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Failure to either disconnec...

Page 27: ...rtest cross log Both front logs to rest slightly on the edge of the rebox window frame Center the front logs side to side in relation to the rebox Place it on the right pin located on the rear log Res...

Page 28: ...rectly can leak carbon monoxide a ect the performance of the replace damage components cause overheating resulting in dangerous conditions Damage caused by incorrect window installa tion is not covere...

Page 29: ...e the batteries from the receiver or the handset This could cause a short circuit to the receiver CAUTION DO NOT PUT BATTERIES IN THE REMOTE CONTROL RECEIVER until the wires are con nected to the burn...

Page 30: ...dset should be located away from any other heat source and not in direct sunlight as this may a ect the temperature sensor located in the remote handset Installation Check Operation Turn the replace a...

Page 31: ...with the heater The Contemporary Front is equipped with a barrier screen The barrier screen is designed speci cally to prevent any contact with the glass of the replace which becomes hot during operat...

Page 32: ...O GDSWHU 9 70 7 7 OXPLQXP OH LEOH LQHU RU GLDPHWHU 127 SO OLQHU DSSURYHG WR 1 8 6 VXLWDEOH IRU YHQWLQJ JDV DSSOLDQFHV V PDQXIDFWXUHG E OH OH PDVWHU DQG RWKHUV 6HULHV ODVKLQJV 5RRI ODVKLQJ 9 7 7 69 5RR...

Page 33: ...mage to the unit due to i Improper installation operational or environmental conditions ii Inadequate ventilation in the area or competition for air from other household equipment or appliances iii Ch...

Page 34: ...ooked Olive for Pilot Injector 720A196 22 Olive Nut for Pilot Pipe 420K385 23 Electrode 4001856 24 Electrode Retaining Nut 4001855 25 Thermocouple 4000061 26 Pilot Gasket A 4000139 27 Pilot Mount 4000...

Page 35: ...ne gas 18 20 25 21 22 23 24 19 43 44 45 1 2 3 4 5 6 7 8 46 49 48 47 9 10 11 12 13 14 15 16 17 26 27 28 29 30 31 32 33 34 35 36 37 38 39 42 40a 40b 14a Natural gas Propane gas 13a 41 50 51 52 53 54 55...

Page 36: ......

Page 37: ...n provided will be used for customer records only Online Warranty registration at www valor replaces com Cut out page ll information and mail to Miles Industries Ltd Fireplace Information Model Number...

Page 38: ...Shut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valor replace...

Reviews: