Valor 739-72ILN Installation & Owner'S Manual Download Page 1

This appliance may be installed in an after-

market permanently located, manufactured 

(mobile) home where not prohibited by local 

codes.

This appliance is only for use with the type 

of gas indicated on the rating plate. This 

appliance is not convertible for use with 

other gases, unless a certifi ed kit is used.

HOT GLASS

 WILL 

CAUSE BURNS.

DO NOT TOUCH 

GLASS 

UNTIL COOLED.

NEVER 

ALLOW CHILDREN 

TO TOUCH GLASS.

DANGER

!

A barrier designed to reduce the risk of burns from the hot 
viewing glass is provided with this appliance and shall be 
installed for the protection of children and other at-risk 
individuals.

Ce guide est disponible en français sur demande.

This appliance is a domestic room-heating 

appliance. It must not be used for any other 

purposes such as drying clothes, etc.
This appliance is suitable for installation in 

a bedroom or bed sitting room.

INSTALLER

Leave this manual 

with the appliance.

CONSUMER

Retain this manual 

for future reference.

Please read this manual 

BEFORE 

installing and 

operating this appliance.

INSTALLATION & OWNER’S MANUAL

— Do not store or use gasoline or other 

fl ammable vapors and liquids in the 

vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

 ▪ Do not try to light any appliance.

 ▪ Do not touch any electrical switch; do 

not use any phone in your building.

 ▪ Leave the building immediately.

 ▪ Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas 

supplier’s instructions.

 ▪ If you cannot reach your gas supplier, 

call the fi re department.

— Installation and service must be 

performed by a qualifi ed installer, 

service agency or the gas supplier.

  

!

  WARNING

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly 

could result in serious injury, death, or 

property damage.

Direct Vent Gas Insert 739-72ILN / 739-72ILP

with

 

Contemporary Black Front & Logs

Legend G3

4004616-10

©2018, Miles Industries Ltd.

Summary of Contents for 739-72ILN

Page 1: ...droom or bed sitting room INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Please read this manual BEFORE installing and operating this appliance INSTALL...

Page 2: ...Check ignition spark 29 Check Operation 30 Adjust Aeration if necessary 30 Install Handset Wall Holder 30 Install Front and Barrier Screen 31 Approved Venting Components 32 Warranty 33 Spare Parts 34...

Page 3: ...s Clothing or ammable material should not be placed on or near the appliance This unit must be used with a vent system as de scribed in this installation manual No other vent sys tem or components may...

Page 4: ...sk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at risk individuals a safe distance from the replace Keep the remote control handset...

Page 5: ...ss window Do not let children touch the glass or any parts of your replace even after it is turned o as it is still hot Use the barrier screen provided with the trim or a gate to reduce the risk of se...

Page 6: ...g the pilot See full lighting instructions on page 11 of this manual Introduction Thank You For purchasing a Valor by Miles Industries Your new radiant gas heater is a technical appliance that must be...

Page 7: ...rn o gas supply and call your dealer for service assistance How to Ensure Your Fireplace Cannot Be Turned ON Inadvertently The best way to ensure your replace will not turn on is to turn it o includin...

Page 8: ...splay press on the AUTO button while the display ashes 4 Let go and wait until the ashing stops The remote shows the time you set It also shows the current temperature Setting the temperature Use this...

Page 9: ...urn o when you leave 5 Press the TIMER button and hold it until P2 appears and ashes Let go While ashing push the buttons hour and minutes to set the time at which you want your replace will turn back...

Page 10: ...Conversion propane gas Other accessories 755CFK Circulating Fan Kit 759EBL Enamel Liners 760CBL Ceramic Black Fluted Liners 4001515 Valor Red Brick Set Hearth Gate Hearth gates such as Cardinal s Vers...

Page 11: ...above 2 Set the flame adjustment knob as far clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed in partially Do no...

Page 12: ...of the ame safety system Pilot or Flame recti cation device 4 Inspect and ensure the lighting of the main burner occurs within 4 seconds of the main gas valve opening Visual inspection should match th...

Page 13: ...to ceramic glass and should be avoided Our dealers have had good results from the products listed below We cannot however guarantee the results of these products Brasso Polish Plus by Kelkem Cook Top...

Page 14: ...d 7 Reinstall the front and barrier screen WARNING F O R S A F E T Y P U R P O S E ensure the barrier screen is re installed on the replace front after maintenance Servicing Maintenance Hot Glass Plat...

Page 15: ...om appliance to appliance depending on the type of installation and climatic conditions The appliance area must always be kept clear and free from combustible materials gasoline and other ammable vapo...

Page 16: ...t of the valve under the rebox It is retained by a Velcro tab Grab the receiver and pull it out from its location CAUTION DO NOT USE a screwdriver or other metallic object to remove the batteries from...

Page 17: ...et 1 370 m in USA installations must be in accordance with the current ANSI Z223 1 and or local codes having jurisdiction Heating value of gas in some areas is reduced to compensate for elevation cons...

Page 18: ...id wood ooring in front of the replace if allowed may shrink during the heating season due to heat WARNING Some materials or items although safe may discolor shrink warp crack peel and so on because o...

Page 19: ...uter Trim or Surround sold separately X Y Dimensions Cavity Check that masonry step does not interfere with install dimensions or vent pipe If mantel is combustible see section Clearances for allowabl...

Page 20: ...ial that can ignite and burn whether ame proofed or not or plastered or unplastered Non combustible materials Material which will not ignite and burn Such materials are those consisting entirely of st...

Page 21: ...ermination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vertical height 10 ft measured to bottom of termination Maximum horizontal run 4 ft measured center to...

Page 22: ...appliance 3 Check that you have everything 4 Clean cavity chimney ash dump and clean out 5 Install venting pipes 6 Attach conversion plate to existing replace 7 Install and test fan blower if used 8 F...

Page 23: ...ttom of the rebox The access hole must be plugged with non combustible insulation after the gas supply line has been installed See Dimensions section for detailed location of gas inlet Also take into...

Page 24: ...side in a safe place to avoid damage Install Fan if used If the 755CFK Circulating Fan Kit blower is to be installed we suggest that you do it now The fan cavity is accessible from the back of the reb...

Page 25: ...back of the rebox 3 Apply RTV sealant to the collars on the vent slider and t the two liners ensuring that the exhaust liner is connected to the identi ed EXHAUST vent collar Secure with 4 tapping sc...

Page 26: ...pply piping system by closing its equipment shut o valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Failure to either disconnec...

Page 27: ...rtest cross log Both front logs to rest slightly on the edge of the rebox window frame Center the front logs side to side in relation to the rebox Place it on the right pin located on the rear log Res...

Page 28: ...rectly can leak carbon monoxide a ect the performance of the replace damage components cause overheating resulting in dangerous conditions Damage caused by incorrect window installa tion is not covere...

Page 29: ...e the batteries from the receiver or the handset This could cause a short circuit to the receiver CAUTION DO NOT PUT BATTERIES IN THE REMOTE CONTROL RECEIVER until the wires are con nected to the burn...

Page 30: ...dset should be located away from any other heat source and not in direct sunlight as this may a ect the temperature sensor located in the remote handset Installation Check Operation Turn the replace a...

Page 31: ...with the heater The Contemporary Front is equipped with a barrier screen The barrier screen is designed speci cally to prevent any contact with the glass of the replace which becomes hot during operat...

Page 32: ...O GDSWHU 9 70 7 7 OXPLQXP OH LEOH LQHU RU GLDPHWHU 127 SO OLQHU DSSURYHG WR 1 8 6 VXLWDEOH IRU YHQWLQJ JDV DSSOLDQFHV V PDQXIDFWXUHG E OH OH PDVWHU DQG RWKHUV 6HULHV ODVKLQJV 5RRI ODVKLQJ 9 7 7 69 5RR...

Page 33: ...mage to the unit due to i Improper installation operational or environmental conditions ii Inadequate ventilation in the area or competition for air from other household equipment or appliances iii Ch...

Page 34: ...ooked Olive for Pilot Injector 720A196 22 Olive Nut for Pilot Pipe 420K385 23 Electrode 4001856 24 Electrode Retaining Nut 4001855 25 Thermocouple 4000061 26 Pilot Gasket A 4000139 27 Pilot Mount 4000...

Page 35: ...ne gas 18 20 25 21 22 23 24 19 43 44 45 1 2 3 4 5 6 7 8 46 49 48 47 9 10 11 12 13 14 15 16 17 26 27 28 29 30 31 32 33 34 35 36 37 38 39 42 40a 40b 14a Natural gas Propane gas 13a 41 50 51 52 53 54 55...

Page 36: ......

Page 37: ...n provided will be used for customer records only Online Warranty registration at www valor replaces com Cut out page ll information and mail to Miles Industries Ltd Fireplace Information Model Number...

Page 38: ...Shut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valor replace...

Reviews: