Natural Gas
Flashback
shield (for pro-
pane gas only)
Propane gas Air
Shutter Slider
Open
Close
Propane Gas
NG Air Shutter
Slider & Cover
Installation
Check Operation
Turn the fi replace fl ame up and down using the
remote control to confi rm that the full range of inputs
is achieved—see the remote control operation
instructions starting on page 9.
Adjust Aeration (if necessary)
Light the fi re and allow the unit to warm up for 10–15
minutes to evaluate the fl ame picture. Burners are
equipped with an adjustable shutter to control primary
aeration. See the fi gures below. The shutters are
factory-set to an aeration gap which will give optimum
performance for the vast majority of installations.
Depending of fuel bed used, altitude and other
considerations, the fl ame picture may be improved by
adjusting the aeration. The need for adjustment should
be determined only by operating the appliance with the
fuel bed, liners and window installed and evaluating the
fl ame picture after a 15-minute warm-up.
Increasing aeration (open)
will cause the fl ames
to appear more transparent and blue showing more
ceramic log glow.
Decreasing aeration (close)
will cause the fl ames to
appear more yellow or orange showing less ceramic
log glow.
Too little aeration may result in black carbon
forming and dropping into the
fi
rebox.
Air Shutters
Synchronize Remote Control
The receiver and the handset of the remote control
system must be initially synchronized before the fi rst
use.
1. With a thin object, press and hold the receiver’s reset
button until you hear one short and one long beep.
Release the button after the second beep.
2. Within the subsequent 20 seconds, press the small
fl ame button ( ) on the remote handset until you hear
two short beeps confi rming the synchronization is
set.
This is a one time setting only and is not required when
changing the batteries in the remote handset. The
remote control system is now ready to use.