background image

1

Note: This kit must be installed or serviced 

by a qualified installer, service agency 

or gas supplier. These instructions are 

to be used in conjunction with the main 

installation instructions for the above 

listed models.

Overview

The 720SWK Sidewall Co-Linear Terminal Kit allows ap-

proved Valor units listed above only to be vented using 

approved 3-inch flexible vent liners to penetrate an ex-

isting masonry solid-fuel burning fireplace and connect 

to 720SWK horizontal termination rather than a vertical 

termination at the top of the chimney.

530 models.

 530IN/IP model fireplaces will also require 

a 556CLA Co-Linear Adapter. 530 model fireplaces do 

not require de-rating. This kit cannot be used with the 

530CSK Coal effect fuel bed.

739-72ILN/ILP models

. Use of this kit requires the stan-

dard 739-72ILN/ILP fireplace to be modified by remov-

ing the inlet air restrictors only. No derating is necessary 

with this model.

RF24JDN/JDP with RA24CL models.

 Use of this kit 

requires a RF24JD firebox with a RA24CL Co-linear Vent 

Plate. Note: The vent restrictor plates located within inlet 

collar of the co-linear vent plate will need to be adjust-

ed—see RF24JD installation section of this manual.

1000KN/KP models.

 Use of this kit requires a 1000CLA 

Co-Linear Adapter. 

4004476-07

© 2020, Miles Industries Ltd. All rights reserved.

Sidewall Co-Linear Terminal Kit

Use ONLY with Valor following heater models:

Portrait 530IN/IP, 530INI/IPI, G3 739-72, Retro

fi

 re RF24JD, H3 1000K

(cannot be used with 530CSK Coal e

 ect models)

For Valor heater G3 models 739M, use 720SWK-M kit.

For Valor heater G3.5 and G4 models 700, 780 and 785, use 720SWK-M2 kit.

INSTALLATION INSTRUCTIONS

720SWK

WARNING

If these instructions are not followed 

exactlly, a fire or explosion may result 

causing property damage, personal 

injury or loss of life.

Please leave this manual with the homeowner.

Sidewall terminal

Front

Rear

12”

12”

8-1/2”

3”

intake

3”

exhaust

Kit content

Conversion label—

739-72 units only

Kit Contents

•  Sidewall terminal 4004410
•  Conversion labels 4004509 

(739-72 units only) (1 NG, 1 LPG)

Summary of Contents for 720SWK

Page 1: ...24JDN JDP with RA24CL models Use of this kit requires a RF24JD firebox with a RA24CL Co linear Vent Plate Note The vent restrictor plates located within inlet collar of the co linear vent plate will need to be adjust ed see RF24JD installation section of this manual 1000KN KP models Use of this kit requires a 1000CLA Co Linear Adapter 4004476 07 2020 Miles Industries Ltd All rights reserved Sidewa...

Page 2: ...all terminal may be used but will require restrictors See 530 section further in this manual May be used with top or rear outlet requires 556CLA Co Linear Adapter 720SWK Terminal 3 Liners 3 min Bend Radius 530INI IPI fireplaces Cannot be used with 530CSK Coal effects fuel bed 530IN IP fireplaces Cannot be used with 530CSK Coal effects fuel bed 530INI IPI 530IN IP Portrait Fireplaces ...

Page 3: ...See the table below to find out which position is optimal for each type of installation To fit the restrictors loosen the two center screws of the left and right inlet ports Place the restrictor assembly under the screw heads and tighten the center screws To set the adjustable restrictor piece loosen the two screws position the adjustable piece according to the diagram below and tighten the screws...

Page 4: ...pliance into the masonry cavity 1 Remove the inlet air restrictor discs a Remove rear log support held in place by two screws at the rear and two on front tags behind burner rail b Remove air duct held in place by two screws at the top and one screw on each side c Remove two restrictor discs held in place by three fixing screws of the six visible remove every second screw d Reinstall air duct and ...

Page 5: ...ors in supplied position mid point Release 4 screws and push restrictors outward to open up vent Tighten screws RF24JD fireplaces with RA24CL Co linear vent plate ONLY Min 3 0 Max 5 0 Between 3 and 5 fully open restrictors Beyond 5 0 the sidewall terminal may be used but leave restrictors opened at mid point as supplied 720SWK Terminal 3 Liners 3 min Bend Radius Mid point Fully open RF24JD Retrofi...

Page 6: ...es with 1000CLA Co linear Adapter ONLY 1000K H3 Fireplaces Min 3 0 Max 10 0 Beyond 10 0 the sidewall terminal may be used but may require restrictors 720SWK Terminal 1000CLA Co Linear Adapter 3 Liners 3 min Bend Radius ...

Page 7: ...n whether or not a fan or shut off valve will interfere when planning routing of the gas line Existing Glass Doors and Wire Screens Existing glass doors must be permanently removed prior to installing the gas fireplace Combustible Mantels Combustible mantel clearances must conform to those required for the original solid fuel fireplace into which the gas fireplace is being installed Attach Convers...

Page 8: ...ied Note the asymmetrical overlap of the hole for the liners when mounting the terminal Seal the flanges of the terminal to the masonry using silicone sealant 5 Carefully pull any excess liner down within the existing fireplace cavity ensuring the liners do not sag and are not crimped or torn 6 Connect the liners to the collars on fireplace using 3 screws per liner or gear clamps Ensure the exhaus...

Page 9: ...utilisez la Sortie 720SWK M2 GUIDE D INSTALLATION 720SWK Étiquette de conversion modèles 739 72 seulementy Concept La Sortie d évacuation colinéaire murale 720SWK permet l évacuation au mur pour les foyers certifiés indiqués ci dessus par raccord à conduits flex de 3 pouces certifiés pénétrant un foyer de maçonnerie existant à combustibles solides et se branchant à la sortie d évacuation horizonta...

Page 10: ...ilisée mais le foyer exige des restricteurs d air Consultez la section 530 de ce guide Peut être utilisé avec évent dessus ou arrière exige Raccord colinéaire 556CLA Sortie 720SWK Conduits de 3 Rayon de courbe minimum de 3 Foyers 530INI IPI Ne peut pas être utilisé avec le lit de combustion Effet Charbon 530CSK Foyers 530IN IP Ne peut pas être utilisé avec le lit de combustion Effet Charbon 530CSK...

Page 11: ...la configuration d évacuation Consultez le tableau ci dessous pour voir quelle est la position optimale pour chaque type d installation Pour fixer le contrôleur dévissez les deux vis du centre des entrées d air Placez le contrôleur sous les têtes de vis et reserrez les vis Pour ajuster la pièce réglable déserrez les deux vis réglez la pièce selon l illustration appropriée ci dessous et reserrez le...

Page 12: ...le brûleur Min 3 pi Max 10 pi À plus de 10 pieds la sortie murale peut être utilisée sans enlever les restricteurs d air Conduits de 3 Rayon de courbe minimum de 3 Foyers 739 72ILN ILP Foyers G3 739 72ILN ILP b Enlevez la canalisation d air tenue en place par deux vis en haut et une vis de chaque côté c Enlevez les deux disques de restriction d air tenus en place par trois vis de fixation parmis l...

Page 13: ...tié Dévissez 4 vis et poussez les restricteurs vers l extérieur pour ouvrir l évent Resserrez les vis Foyers RF24JD avec Plaque d évent co linéaire RA24CL SEULEMENT Min 3 0 Max 5 0 Entre 3 et 5 pieds ouvrez les restricteurs À plus de 5 pieds la sortie au mur peut être utilisée mais laissez les restricteurs ouverts à moitié tel que fournis Sortie 720SWK Conduits de 3 Rayon de courbe minimum de 3 Ou...

Page 14: ...A SEULEMENT Min 3 0 Max 10 0 À plus de 10 0 la sortie murale peut être utilisée mais un restricteur d air peut être exigé dans le foyer Sortie d évacuation 720SWK Raccord colinéaire 1000CLA Conduits de 3 Rayon de courbe minimum de 3 Foyers H3 1000K ...

Page 15: ...ce possible que l installation d un ventilateur ou d un robinet de sûreté peuvent avoir avec la parcours de la conduite de gaz Portes de verre et pare étincelles existants Les portes de verre doivent être enlevées complètement avant d installer le foyer à gaz Manteaux de cheminée combustibles Les dégagements pour les manteaux de cheminée combustibles doivent être conformes aux dégagements requis p...

Page 16: ...on fournies Notez le chevauchement assymétrique du terminal sur le trou pour les conduits lorsque vous fixez la sortie 5 Tirez soigneusement tout excès de conduits vers l intérieur de la cheminée en vous assurant que les conduits ne sont pas affaissés coincés ou déchirés 6 Raccordez les conduits aux buses du foyer à l aide de 3 vis par conduits ou colliers de serrage à engrenage Assurez vous que l...