4” (102 mm)
A
B
Non-combustible hearth
With optional
Fan: depth
+3” (76 mm)
Do not put
furniture or
objects within
36” (914 mm)
of the front of
appliance
Sidewall Clearances
Minimum
distance from side of appliance (liner box) to
combustible wall: 4” (102 mm).
Floor/Hearth Clearances
Combustible shims/supports may be used beneath
the appliance to level or raise the appliance within the
existing fi replace cavity.
Combustible fl ooring/hearths
in front
of the appliance
must be at a minimum of 4” (102 mm) below the
bottom of the appliance (note—may be subject to local
authority approval).
sidewall
WARNING
Some materials or items, although safe, may discolor, shrink, warp, crack, peel,
and so on because of the heat produced by the fi replace. Avoid placing candles,
paintings, photos, and other items sensitive to heat around the fi replace.
Combustible Mantel Clearances
*Measure taken from the underside of the mantel to fi nished
hearth or surface that the unit is sitting on.
Finishing Materials
Combustible materials:
Material such as wood,
compressed paper, plant fi bers, plastics or any material
capable of igniting and burning, whether fl ame-proofed
or not, plastered or un-plastered.
Non-combustible materials:
Material such as steel,
iron brick, tile, concrete or materials that bear the UL
mark for zero (0) fi re rating.
WARNING
HOT GLASS! The use of a screen in front of the
glass is highly recommended particularly in
households with children.
WARNING
HOT HEARTH / FLOOR! The hearth or fl oor in
front of the fi replace may become very hot
when the fi replace heats. Do not use the hearth
as a seat or shelf. Solid wood fl ooring in front
of the fi replace (if allowed) may shrink during
the heating season due to heat.
!
!
!
Mantel Pro-
jection A
0-6”
(0-152 mm)
8”
(203 mm)
10”
(254 mm)
12”
(305 mm)
Mantel
Height B*
33”
(838 mm)
35”
(890 mm)
37”
(940 mm)
39”
(990 mm)