background image

OWNER’S GUIDE

Page 7

Figure 2 Ultimate Controls

OPERATING YOUR FIRE

The pilot may be left alight.  It is advisable, however, that the pilot is turned off if the
premises are to be left unoccupied for a lengthy period.
For your safety the fire is fitted with a flame supervision device which will shut off the
gas supply if for any reason the pilot goes out.  This device incorporates a fixed probe
which senses the heat from the pilot flame.  If the probe is cool the device will prevent
any gas flow unless the pilot lighting knob is held in. This device also stops the fire being
turned back on until it is safe after it has been turned off.
If, for any reason, the fire goes out or if the fire is turned off, always 

wait at least three

minutes before attempting to relight
If the  device starts to shut off the gas
frequently, get expert advice.

Model 5400 Ultimate

The controls are shown in figure 2.

To light the pilot

 

Push in the right control knob (the pilot

lighting knob) and, while keeping it depressed,
turn anticlockwise through the ignition position
marked         and up to the pilot position
marked      . The spark should light the pilot. The pilot flame can be seen by looking
through the gap near the left side of the coal front (See figure 4).

 

When the pilot has lit, keep the right hand control knob depressed for a few seconds to

prevent the flame supervision device from shutting off the gas supply while its probe
warms up, as explained above, then release it. If the pilot does not remain alight turn the
knob back to the off position marked 

.

 Wait a few seconds and repeat the lighting

sequence.

To Light the Main Burner

 

Partially depress the right control knob and turn to the main burner position marked

The main burner should now light at its low position.

 

The left-hand knob is for burner flame adjustment. Turning it anticlockwise should

gradually increase the flame height and heat output. Turning clockwise reduces the flame
height and heat output.

 

The burner flame control does not have to be re-set every time the fire is lit. Once set,

it can be left at that position allowing you to use the right hand control only to ignite the
burner at the set flame height.

To Turn Off the Main Burner Only

 

Turn the right hand control knob to the pilot position marked      .

Summary of Contents for 5402 HOMESTYLE

Page 1: ...es sufficient details to enable the your appliance to be operated and maintained satisfactorily However if further information is required the Valor AdviceLine will be pleased to help Please telephone...

Page 2: ...st Standards Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a CORGI registered company...

Page 3: ...rts 12 C U S T O M E R C A R E Thank you for choosing Valor All Valor gas fires are designed to meet the most stringent quality performance and safety requirements to provide our customers with many y...

Page 4: ...of additional shelf depth Provide a minimum clearance of 51mm each side of the fire for servicing access Provide a suitable guard which complies with BS 6539 or 6778 for the protection of young childr...

Page 5: ...el bed and rear wall correctly in position or if they are damaged H Put paper or any other material on the fire H Place any carpet rug or other soft surface material under or within 300mm forward of t...

Page 6: ...NER S GUIDE Page 6 DIMENSIONS GAS CONSUMPTION Gas Consumption This appliance has a maximum gas at input its highest setting of 3 65kW Gross The maximum heat output is 2 7kW Figure 1Appliance dimension...

Page 7: ...the ignition position marked and up to the pilot position marked The spark should light the pilot The pilot flame can be seen by looking through the gap near the left side of the coal front See figur...

Page 8: ...ion marked Wait a few seconds and repeat the lighting sequence To Light the Main Burner Partially depress the right control knob and turn to the main burner position marked The main burner flames are...

Page 9: ...at the back of the casting from the keyholes in the surround sides Remove the two screws securing the bottom of the front surround to the sides of the convection box Raise the front surround to allow...

Page 10: ...top of the window over the top of the firebox opening Refit the three spring loaded screws and washers Tighten sufficiently to seal to the firebox Replace the case front To Clean the Fuel Bed or Rear...

Page 11: ...atteries See figure 9 Fitting Tile sets Model 5402 Homestyle Only A wide range of alternative tile designs are available from your supplier To change the tiles The top casting will have to be removed...

Page 12: ...n fitting these spares please follow the instructions Description Part no Ceramic rear wall 571789 Ceramic fuel bed 571839 Window unit 571849 Spring loaded thumb screw for window 571899 To help us qui...

Reviews: