![Valor 530 536CXB Installation Booklet Download Page 3](http://html1.mh-extra.com/html/valor/530-536cxb/530-536cxb_installation-booklet_3384510003.webp)
26”
(framing plate)
(fr
aming pla
te)
31-1/4”
21-3/4”
(cast front)
(c
ast fr
on
t)
27-7/8”
7/8”
High
raised
plinth
Ceiling
‘A’
‘B’
1” max.
1/2” min.
1” max.
1/2” min.
11” min.
36”
min.
36” min. to
combustibles
9”
Mantel
Optional Top Outlet
ZC Stand-offs
6-5/8” dia.
6-5/8”
dia.
21-5/8”
25-1/4”
31”
5”
7/8”
plinth
insul.
2”
26-1/4”
20”
26”
11”
9”
5”
‘D’
‘E’
Mantel
leg
See table
2”
Mantel depth “A”
Min. clearance “B”
Up to 7”
4”
Above 7” up to 8”
5”
Above 8” up to 9”
7”
Above 9” up to 10”
8”
Above 10” up to 12”
9”
More than 12”
9”+extra 1” for every
1” depth above 12”
Mantel leg
projection “D”
Min. clearance from
appliance side “E”
Up to 8”
0”
More than 8”
6”
Dimensions &
Clearances
The Valor model 530 heater with the 536CXB President ZC Cast Front comes ready for installation as a zero
clearance unit into combustible type framing, without need for a separate zero clearance kit. The 530 installed
without the standard zero clearance stand-off spacers may also be installed into existing solid-fuel burning fireplaces
provided space and local codes permit.
Hearth Requirements
A 7/8” high plinth is supplied to raise the heater and ensure a base at the proper height for the cast front to sit on
regardless of floor finish height. If not using the plinth supplied, you MUST make allowance for floor finish and raise
(shim) the heater up so the bottom of the heater sits at the finished floor/hearth height, otherwise, the cast front will
not sit at the proper height.
A
non-combustible
hearth is
not
required in front of this appliance.
Floor Requirements
The 530 heater is approved for installation directly on any combustible material
other than
soft flooring material
such as carpet or vinyl.
Mantel Requirements
The 536CXB President ZC Cast Front may be installed with a combustible mantel provided clearances are
maintained as indicated in the Dimensions and Clearances below and in the Framing diagrams on the following
pages. Be aware that although safe, some combustible materials and finishes at the listed clearances may, over
time, discolor, warp, or show cracks. Care should be taken when choosing materials—consult your fireplace dealer.
INSTALLATION WITH 530 ENGINE