Valor 417 Owner'S Manual Download Page 8

8

MAINTENANCE

Debris from the chimney

The opening at the back of the appliance must be always kept clear
of obstruction. If the chimney has previously been used for coal
fires or is of normal construction it is possible that loose mortar
and soot can fall behind the appliance. This, in time, may build up
until the flue becomes restricted or even blocked. The chimney
should be checked annually to ensure continued clearance of the
combustion products and to ensure that no excessive build up of
soot or other debris occurs. The appliance should be serviced
regularly in order to ensure good mechanical operation.
It is important that this work is carried out by a competent person
such as a CORGI registered installer.

General servicing

If you require any attention to your fire, contact your supplier
mentioning the model number. It will also be helpful if the
appliance serial number is quoted. This will be found on a label
next to the control knob. It is visible when the bottom front cover
is removed.

In the United Kingdom it is the law that a landlord must have  any
gas appliance and pipework which is situated in a tenant’s premises
checked for safety at least every 12 months. We recommend that all
gas appliances, wherever situated, are checked annually by a
competent person (In the UK, a CORGI registered installer).

The ceramic fuel bed items are customer replaceable. When
ordering please quote the number shown below.

Description

Part No

Rear wall

 

 545999

Front base coal halves

 546009

Rear base coal

563359

Pack of  7 top coals

 563369

Right side wall

 546039

Left side wall

  

 546049

When fitting replacement coals follow the instructions.

Summary of Contents for 417

Page 1: ...ou use and care for your Valor gas fire Please read thoroughly before using and keep for future reference We trust that these instructions give sufficient details to enable this appliance to be operat...

Page 2: ...material and which is not more than 150mm deep is 750mm this will give a clearance of 150mm above the top edge of the outer surround for shelves deeper than 150mm add 12 5mm to the above clearance for...

Page 3: ...Gross and a minimum gas input at the low setting of 3 6 kW Gross To calculate the running cost of your fire multiply the gas consumption gas input by the cost of gas which you will find on your gas b...

Page 4: ...nd coal at the front left side Keep the button at the PILOT IGN position for a further ten seconds This will prevent the flame sensing device from shutting off the gas while its probe warms up as expl...

Page 5: ...held away from your face so that you avoid inhaling the dust We do not recommend the use of a normal domestic vacuum cleaner which may blow dust back into the air We suggest that you remove the coals...

Page 6: ...ox and in the recesses at the sides of the base coals The markings L R should be at the at the back bottom corners and facing to the centre of the back of the firebox See figure 7 5 Install the 7 loos...

Page 7: ...the large coals See figure 9 Place the left side coal so that you will be able to see the pilot flame below the coal 5 3 Place the three remaining coals behind and approximately midway between each o...

Page 8: ...eneral servicing If you require any attention to your fire contact your supplier mentioning the model number It will also be helpful if the appliance serial number is quoted This will be found on a la...

Page 9: ...ds Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a Corgi registered company All our ga...

Reviews: