 Prepare Appliance

1. If the 

fi

 replace is already installed, remove any in-

stalled trims, fronts, doors, and window.

2.  Locate gas shut o

  valve and isolate gas supply. 

3.  Remove the media platform (no screws).

4.  Detach the burner (3 screws). Slide it to the right, 

and lift it out.

Replace Main Burner Injector

1.  Using a 7/16” socket wrench with an extension, 

unscrew and remove the main burner injector from 

inside the injector block.

2.  Replace the old injector with the new injector from 

the kit using the socket wrench to tighten. 

Use 

thread sealant when installing the new injector.

Rotate Air Shutter Stopper

Adjust the air shutter stopper for your desired fuel. 

Remove the two screws holding the stopper in place, 

and rotate the stopper to the appropriate position.

Natural

Gas

Propane 

Gas

Remove 2-piece platform

2

Summary of Contents for 1800KNGK

Page 1: ...d to set the manifold pressure 1800KNGK 1800KPGK Gas Conversion Kit Use with Valor L3 1800K Heater Models ONLY INSTALLATION MANUAL L3 Series 4008258 01 2020 Miles Industries Ltd Kit Contents 1 Pilot i...

Page 2: ...ng a 7 16 socket wrench with an extension unscrew and remove the main burner injector from inside the injector block 2 Replace the old injector with the new injector from the kit using the socket wren...

Page 3: ...tions fit through the opening Caution Be careful not to damage any of the components beneath the module plate Replace Pilot Injector 1 Remove pilot shield 2 screws 2 Remove the pilot hood by pulling o...

Page 4: ...iquid detergent or soap solution to all connection joints that were taken apart and reassembled Bubbles forming indicate a gas leak Bypass screw Valve WARNING NEVER use an open flame to check for leak...

Page 5: ...eration Instructions 2 Fit the label This appliance was converted on by near the data label fitted in 1 3 Fit the label This control has been converted on the left hand side of the appliance near the...

Page 6: ...nversion de gaz 1800KNGK 1800KPGK Utilisez avec les foyers Valor L3 1800K SEULEMENT GUIDE D INSTALLATION S rie L3 Contenu du kit 1 Injecteur de veilleuse 1 Injecteur de br leur 1 Vis d indice minimum...

Page 7: ...z l injecteur du br leur 1 l aide d une cl cliquet avec rallonge et une douille de 7 16 d vissez et enlevez l injecteur du br leur du bloc de l injecteur 2 Remplacez l injecteur par celui fourni avec...

Page 8: ...a plaque du br leur 10 vis 3 En faisant tr s attention soulevez la plaque en com man ant par l arri re et pivotez la vers le haut pour d gagez les pi ces qui y sont attach es en dessous Remplacez l in...

Page 9: ...une solution savonneuse sur tous les rac cords La formation de bulles indique une fuite de gaz R glez et v rifiez la pression d admission 1 Fixez un manom tre la connexion de v rification de pression...

Page 10: ...on tel qu indiqu dans le Guide d installation du foyer R glez l obturateur d air Une fois le lit de combustion install r glez l obturation 1 Rep rez le levier d a ration derri re la paroi avant de l a...

Reviews: