Valor 1800KNGK V Download Page 1

WARNING

This conversion kit shall be installed by 

a quali

fi

 ed service agency in accordance 

with the manufacturer’s instructions and 

all applicable codes and requirements 

of the authority having jurisdiction. If 

the information in these instructions is 

not followed exactly, a 

fi

 re, explosion 

or production of carbon monoxide 

may result causing property damage, 

personal injury or loss of life. The 

quali

fi

 ed service agency is responsible 

for the proper installation of this kit. The 

installation is not proper and complete 

until the operation of the converted 

appliance is checked as speci

fi

 ed in the 

manufacturer’s instructions supplied with 

the kit.
Use this manual in conjunction with the 

installation manual supplied with the 

appliance.

General Notes Regarding Conversion

The conversion may be done before or after the 

appliance is installed. However, if the unit has been 

installed and wall 

fi

 nish applied, the burner module 

must be removed from the 

fi

 replace (see page 3). 

Note that the gas must be connected to set the 

manifold pressure.

1800KNGK / 1800KPGK Gas Conversion Kit

Use with Valor L3 1800K Heater Models ONLY

INSTALLATION MANUAL

L3 Series

4008258-01

©2020, Miles Industries Ltd.

Kit Contents

• 1 Pilot injector
• 1 Main burner injector
• 1 Minimum rate bypass screw
• 1 Set of conversion labels

Tools Required

• 7/16” socket driver with extension to install main 

burner injector

• Small (jewelers size) 

fl

 at blade screwdriver, to set pres-

sure

• Small 

fl

 at blade screwdriver, to release pressure tap 

on valve

• Needle nose pliers, to remove bypass screw
• Hex (Allen) wrench, 4 mm or 5/32”, to remove pilot 

injector

• Manometer, to set pressure 
• Wrenches, to disconnect gas line (optional step)
• Phillips (+) screwdriver, to remove burner module 

(optional step)

• 1/4” inner diameter tubing

Speci

fi

 cations

* This appliance is certi

fi

 ed for use from 0–4500 feet. For 

altitudes above 4500 feet, see local codes.

Model 

1800NG 1800LPG

Gas

Natural

Propane

Altitude (Ft.)*

0-4,500 feet*

Input Maximum (Btu/h)

42,000

42,000

Input Minimum (Btu/h)

23,000

23,000

Manifold Pressure (in w.c.)

3.5”

10”

Minimum Supply Pressure (in w.c.)

5”

11”

Maximum Supply Pressure (in w.c.)

10”

14”

Main Burner Injector Marking

DMS#30 DMS#48

Pilot Injector Marking

51

30

Min. Rate By-Pass Screw

260

160

Summary of Contents for 1800KNGK

Page 1: ...d to set the manifold pressure 1800KNGK 1800KPGK Gas Conversion Kit Use with Valor L3 1800K Heater Models ONLY INSTALLATION MANUAL L3 Series 4008258 01 2020 Miles Industries Ltd Kit Contents 1 Pilot i...

Page 2: ...ng a 7 16 socket wrench with an extension unscrew and remove the main burner injector from inside the injector block 2 Replace the old injector with the new injector from the kit using the socket wren...

Page 3: ...tions fit through the opening Caution Be careful not to damage any of the components beneath the module plate Replace Pilot Injector 1 Remove pilot shield 2 screws 2 Remove the pilot hood by pulling o...

Page 4: ...iquid detergent or soap solution to all connection joints that were taken apart and reassembled Bubbles forming indicate a gas leak Bypass screw Valve WARNING NEVER use an open flame to check for leak...

Page 5: ...eration Instructions 2 Fit the label This appliance was converted on by near the data label fitted in 1 3 Fit the label This control has been converted on the left hand side of the appliance near the...

Page 6: ...nversion de gaz 1800KNGK 1800KPGK Utilisez avec les foyers Valor L3 1800K SEULEMENT GUIDE D INSTALLATION S rie L3 Contenu du kit 1 Injecteur de veilleuse 1 Injecteur de br leur 1 Vis d indice minimum...

Page 7: ...z l injecteur du br leur 1 l aide d une cl cliquet avec rallonge et une douille de 7 16 d vissez et enlevez l injecteur du br leur du bloc de l injecteur 2 Remplacez l injecteur par celui fourni avec...

Page 8: ...a plaque du br leur 10 vis 3 En faisant tr s attention soulevez la plaque en com man ant par l arri re et pivotez la vers le haut pour d gagez les pi ces qui y sont attach es en dessous Remplacez l in...

Page 9: ...une solution savonneuse sur tous les rac cords La formation de bulles indique une fuite de gaz R glez et v rifiez la pression d admission 1 Fixez un manom tre la connexion de v rification de pression...

Page 10: ...on tel qu indiqu dans le Guide d installation du foyer R glez l obturateur d air Une fois le lit de combustion install r glez l obturation 1 Rep rez le levier d a ration derri re la paroi avant de l a...