Venting
Vent Material
This unit is approved for installation using
4 x 6-5/8 inches co-axial direct vent pipe and
accessories as listed in the
Approved Venting
Components
section on pages 44–45 of this manual.
Follow the installation instructions supplied with the
individual venting accessories.
This unit may also be converted to co-linear (2 x 3 in)
venting for use in solid-fuel burning
fi
replaces and
chimneys using adapters and accessories—see the
Approved Venting Components
section on pages
44–45 of this manual.
Wall Thickness
The appliance vent is suitable for penetrating a
combustible wall assembly up to 8 inches in thickness.
A non-combustible wall can be of any thickness up to
the maximum horizontal run of vent pipe allowed for the
particular installation.
Framing Vent in Combustible Walls &
Ceilings
When penetrating through combustible walls and
ceilings, frame a minimum of 10 x 10 inches opening
and ensure that the insulation is kept clear of the vent
pipe using either a wall thimble or an attic insulation
shield. Follow the installation instructions supplied with
the individual venting components.
10” (254 mm)
10” (254 mm)
Align the vent
center to the
center of the
frame