Fitting the flexible hoses.
NOTE:
In certain installations the movement of the heater is restricted once
connected to the system pipe work. We therefore recommend that before fitting the
flexible hoses a securing method is chosen, the appropriate section is read and any
necessary work conducted before connecting to the system pipe work. Always ensure
that the heating system is OFF and completely cool before continuing.
1.
Before fitting the flexible hoses it is important to
de-burr and clean both heater and system flow and
return pipes.
2.
Connect the elbowed ends of the flexible hoses to the
product. Connect the other ends to the system pipe work.
The bend radius of the hose must not be less than 60mm
when the heater is fully installed. Open the valves and
check for water leaks.
3.
Vent any trapped air from the system. Use a cloth
underneath the vent screw to catch excess water.
Page 11
©
Baxi Heating U.K. Limited 2009.
INSTALLER GUIDE
Figure 4.
Figure 3.
Figure 2.