Important Electrical Safety

The stove must 

not

be located in front of or under an electrical socket, the socket

must always be accessible in order to disconnect the stove from the electrical supply
for maintenance and cleaning.

Important! This stove must be earthed. 

The stove is supplied with a 3 pin 13 Amp fused re-wireable plug with 1mm² 3

core cable.

The wires in the cable are coloured in accordance with the following code: -

Live =Brown

Neutral = Blue

Earth = Green /Yellow

The electric supply must be safely routed from the stove to an electrical socket.

If the electric cable is damaged, to avoid a hazard it must be replaced by a Valor
Fires authorised service agent, or similarly qualified person (See page 9). All external
wiring between the stove and the electrical supply shall comply with current IEE
regulations. Extension leads should not be used.

Fitting the legs.

The stove is supplied with the four legs removed in order to prevent damage during
transportation. Each leg has raised lugs that locate into holes in the base of the stove
(See figure 2). Locate the legs and secure in place using the screws supplied.

Page 6

INSTALLER AND OWNER GUIDE

© 

Baxi Heating U.K. Limited 2007.

Figure 2. Fitting the feet

Summary of Contents for 860 vienna

Page 1: ...ure reference This guide is intended to help you install and care for your Valor Fires electric stove Please read carefully before installing and using your stove However if further information is req...

Page 2: ...Thank you for choosing Valor Fires All Valor Fires stoves are designed to meet the most stringent quality performance and safety requirements to provide our customers with many years of trouble free s...

Page 3: ...eavy then obtain assistance When lifting always keep your back straight Bend your legs and not your back Avoid twisting at the waist It is better to reposition your feet Avoid upper body top heavy ben...

Page 4: ...use i e Bathrooms Kitchens Shower Rooms Swimming Pools etc Never use aerosols or steam cleaners on or around the stove Never route the electric cable under carpet etc Never install the stove close to...

Page 5: ...soft furnishings etc away from the front of the stove They could obstruct the free flow of hot air from the fan and damage both soft furnishings and the stove Although the stove complies with all the...

Page 6: ...fely routed from the stove to an electrical socket If the electric cable is damaged to avoid a hazard it must be replaced by a Valor Fires authorised service agent or similarly qualified person See pa...

Page 7: ...s Open the pack of loose coal and position the coal on top and in front of the plastic fuel bed Arrange the coal to your liking It is not necessary to use all of the coal Please fill in the details on...

Page 8: ...ug and allowing the stove to cool How do I Clean my stove The stove and plastic parts need only to be wiped clean with a dry soft cloth do not use polishes or abrasive materials I have a problem with...

Page 9: ...plugged in works then there is a good chance that the problem lies with the 13 Amp fuse in the stove plug If either fuse or socket is suspected have them checked by an electrician 3 My stove is on but...

Page 10: ...r your stove with heateam the service division of Baxi Heating UK Limited either by completing and returning the registration card or calling our free telephone registration line on 0800 032 72 44 Our...

Page 11: ...out in this guide Faults caused by inadequate supply of electricity Reimbursement of any third party repair or replacement costs that we haven t been told about or agreed with you in advance Compensa...

Page 12: ...Page 12 INSTALLER AND OWNER GUIDE Baxi Heating U K Limited 2007...

Page 13: ...Page 13 INSTALLER AND OWNER GUIDE Baxi Heating U K Limited 2007...

Page 14: ...Page 14 INSTALLER AND OWNER GUIDE Baxi Heating U K Limited 2007...

Page 15: ...e completed by the customer Figure 5 A LABEL CONTAINING THE FASCIA CODE MAY HAVE BEEN PLACED INSIDE THIS BOX Fascia name Block Capitals Fascia code Can be found on information label Block Capitals A L...

Page 16: ...Baxi Heating U K Limited 2007...

Reviews: